Armoured Unshielded SECUREX® II FAS Fire Alarm, Signal and Security System Cable FAS
Standards
National  CSA C22.2 N° 208, File No. LL23462
Description

 #20 to #12 AWG solid bare copper conductors (stranded conductors optional).  Multiconductors:  3-50 armoured.  Conductor #3 of multiconductor cables is coloured green, suitable for bonding purposes. Armoured constructions must have a minimum of 3 conductors, using the green conductor for bonding only.

Outer jacket is 105°C flame retardant red PVC.  Optional aluminum/mylar shield with tinned copper drain wire.   Rip cord under jacket  for safe, easy jacket stripping.

Interlock aluminum or galvanized steel armour with or without overall jacket.

 

Application

SECUREX® II is a 300V 105°C cable specifically designed for the  interconnection of security system elements:  including fire protective signaling devices such as smoke and fire detectors, fire alarms, and two-way emergency communication systems.

Code Requirements

Although SECUREX® II cable is fire rated to CSA FT4 requirements, Section 32 of the Canadian Electrical Code Part 1 requires the use of mechanical protection for fire alarm cable installations in non-combustible buildings.

RULE 32-102

Subrule (1)

All conductors of a fire alarm system shall be:

installed in metal raceway of the totally enclosed type; or
incorporated in cable having a metal armour or sheath; or
installed in rigid non-metallic conduit where embedded in at least 50mm of masonry or poured concrete, or installed underground; or
installed in electrical non-metallic tubing where embedded in at least 50mm of masonry or poured concrete.
Subrule (2)

Notwithstanding Subrule (1), conductors installed in buildings of combustible construction in accordance with the Rules of Section 12 shall be permitted to be:

nonmetallic sheathed cable; or
fire alarm and signal cable; or
installed in a totally enclosed nonmetallic raceway.
As a cost-effective alternate to metal raceway, SECUREX® II is now available in popular sizes and conductor counts with aluminum interlock armour.


 TOP
Colour Codes

Multiconductor

Cond.
No.

Base
Colour

Longitudinal
Stripe

 

Cond.
No.

Base
Colour

Longitudinal
Stripe

1

Black

 

16

White

Brown

2

Red

 

17

Green

Brown

3

Green

 

18

Yellow

Brown

4

Blue

 

19

White

Orange

5

Brown

 

20

Black

Orange

6

Orange

 

21

Red

Orange

7

Black

White

22

Green

Orange

8

Red

White

23

Brown

Orange

9

Green

White

24

White

Blue

10

Yellow

White

25

Red

Blue

11

Red

Black

26

Yellow

Blue

12

Green

Black

27

Brown

Blue

13

Yellow

Black

28

Black

Red

14

Green

Red

29

White

Red

15

Yellow

Red

30

Brown

Red

Note:  Cables over 30 Conductors will have Black or White insulation with number coding.


SECUREX® II 18 AWG Multiconductor Aluminum Armoured Unshielded

No. of
 Conductors

Ins. Wall

Jacket Wall 

Cable Diameter 

Cable Weight

mils

mm

mils

mm

in.

 mm

lb/mft

kg/km

 3 *

15

0.38

50

1.27

0.451

11.46

88

133

 4 *

15

0.38

33

0.84

0.445

11.30

80

118

 5 *

15

0.38

33

0.84

0.464

11.79

90

134

 6

15

0.38

35

0.89

0.497

12.62

115

171

 8

15

0.38

35

0.89

0.519

13.18

127

188

10

15

0.38

35

0.89

0.544

13.82

151

224

20

15

0.38

50

1.27

0.676

17.16

244

362

30

15

0.38

50

1.27

0.766

19.46

328

487

50

15

0.38

60

1.52

0.910

23.11

501

742

*Jacket thickness and cable diameters are a result of Nexans armouring practice. They meet or 
exceed CSA requirements.


Electrical Properties - Solid Copper Conductors

AWG

12

14

16

18

20

D.C.Resistance

 

 @ 20°C (ohms/km) 

Bare Copper

5.21

8.27

13.60

20.90

33.10

Tinned Copper

5.54

8.79

14.70

22.10

34.40

 

Mutual Capacitance

*

**

*

**

*

**

*

**

*

**

(picofarads/m)

 

Unshielded Cables

108

--

98

--

89

--

82

--

79

--

(Pairs or Singles)

 

O/A Shielded Cables > 6/C

108

197

98

177

89

161

82

148

79

141

O/A Shielded Cables 6/C or less

223

400

203

361

177

318

157

279

154

272

*Capacitance between adjacent conductors.

**Capacitance between one conductor and other conductors connected to shield.


 TOP
Selling delivery information

CAUTION
In case of fire, well-maintained early warning smoke detectors will give an alarm long before non-metallic coverings become combustible.

However, in spite of the widespread and longstanding use of PVC in residential and commercial buildings, all purchasers of PVC insulated/jacketed products should be aware of the following:

Non-metallic coverings of electrical cables can burn and may transmit fire when ignited.
Burning non-metallic coverings may emit gases which are toxic and may generate dense smoke.
Emission of acid gases may corrode metal in the vicinity; e.g., sensitive instruments and reinforcing rods in cement.