Duplex Unjacketed NS75/NS90 Secondary Distribution Cable
REFERENCES
Neutral Supported Cable
Standards
Description
Characteristics
Related Information
Standards
National  CSA C22.2 N° 129
Description

Nexans’ duplex neutral supported cables consist of an assembly of one insulated phase conductor factory-cabled around a neutral conductor. The neutral conductor is the supporting member. The conductor is insulated with polyethylene (PE) rated 75 °C or crosslinked polyethylene (XLPE) rated 90 °C.

 

Application

They are intended for use either as a service drop cable between a power pole and the service entrance, or as a secondary distribution cable between poles. Their use is limited to circuits not exceeding 600 volts phase-to-phase.

Duplex service drop cables are intended to deliver single-phase power from the secondary power line or pole-mounted transformer to the service entrance conductors at the user’s building or other structures.

Optional construction includes an insulated control/supply conductor.


 TOP
Characteristics
Construction characteristics
With smaller neutral conductor No  
Number of conductors 2  

 TOP
NS75/NS90 Duplex Unjacketed Physical Data

 

Phase Conductor

Full  Size Neutral Support

Cable Assembly

Code Word

Size
(Stranding)
AWG/kcmil

Diameter
(mm)

Insulation
Diameter
(mm)

Size
(Stranding)
(AWG)

Area
(mm2)

Rated
Strength
(kN)

Overall
Diameter
(mm)

Total 
Weight
(kg/km)

Arcturus

6 (7)

4.29

6.6

6 (6/1)

15.48

5.20

11.3

112

Castor

4 (7)

5.41

7.8

4 (6/1)

24.71

8.14

13.6

170

Deneb

2 ((7)

6.81

9.2

2 (6/1)

39.23

12.40

16.5

260

-

1 (7)

7.59

10.7

1 (6/1)

49.48

15.50

19.1

335

Vega

1/0 (7)

8.53

11.7

1/0 (6/1)

62.39

19.10

21.1

420

-

2/0 (7)

9.55

12.7

2/0 (6/1)

78.65

23.80

23.2

520

-

3/0 (7)

10.74

13.9

3/0 (6/1)

99.23

29.70

25.7

650

-

4/0 (7)

12.07

15.2

4/0 (6/1)

125.10

37.50

28.4

810

-

266.8 (18)

13.64

17.8

266.8 (26/7)

157.20

50.10

34.1

1019

-

336.4 (18)

15.32

19.5

336.4 (26/7)

198.20

62.31

37.8

1270

-

397.5 (18)

16.74

20.9

397.5 (26/7)

234.20

72.65

40.8

1490

-

477 (18)

18.34

22.5

477 (26/7)

281.10

87.17

44.3

1772

-

500 (18)

18.69

22.9

500 (30/7)

312.50

109.40

45.8

1995

Code words are from the Aluminum Association Publication 50, 7th Edition, Table C17 (add " /  XLP " suffix for NS90)
NS75 with black LLDPE (optionally MDPE) insulation, 1/c red extruded stripes, 1/c blue extruded stripes
NS90 with black XLPE insulation, 1/c red extruded stripes, 1/c blue extruded stripes
Neutral support conductors 266.8 kcmil and larger are round wire ACSR, minimum Type 16, 
otherwise Type 100 compact  ACSR conductors are used.
Overall diameter is the multiplex assembly circumscribing circle diameter


NS75/NS90 Duplex Unjacketed Electrical Data

Code
Word

Phase Size
(Stranding)
AWG
or kcmil

Phase Conductor Resistance

Inductive
Reactance
(ohm/km)

Cable Ampacity (amps)

Rdc @ 20ºC
(ohm/km)

Rac @ 50ºC
(ohm/km)

Rac @ 75ºC
(ohm/km)

Rac @ 90ºC
(ohm/km)

NS75

NS90

Arcturus

6 (7)

2.190

2.480

2.700

2.840

0.1048

80

95

Castor

4 (7)

1.380

1.560

1.700

1.780

0.0991

105

125

Deneb

2 ((7)

0.865

0.979

1.070

1.120

0.0943

140

165

-

1 (7)

0.687

0.778

0.848

0.890

0.0979

160

190

Vega

1/0 (7)

0.544

0.616

0.672

0.705

0.0955

185

220

-

2/0 (7)

0.432

0.489

0.533

0.559

0.0933

210

255

-

3/0 (7)

0.343

0.388

0.423

0.444

0.0912

245

290

-

4/0 (7)

0.271

0.307

0.335

0.352

0.0893

280

335

-

266.8 (18)

0.215

0.244

0.268

0.282

0.0914

325

390

-

336.4 (18)

0.171

0.193

0.215

0.225

0.0894

375

450

-

397.5 (18)

0.144

0.164

0.184

0.193

0.0881

415

500

-

477 (18)

0.121

0.136

0.155

0.163

0.0867

460

560

-

500 (18)

0.115

0.130

0.149

0.156

0.0865

500

605

Rdc at 20°C is taken from CSA C49.5
Rac at 90°C is only applicable to NS90 cable
Ampacities are from the CE Code C22.1-06, Table 36A, based on 30°C ambient air,
0.6 m/s wind, and solar radiation of 1025 W/m²


 TOP
NS75/NS90 600V Cable Construction
NS75/NS90 600 V Cable Markings
NS75/NS90 600v Optional Features


Nexans © copyright 2001 - 2012   Legal Notice | Contact Us | Site Map