Triplex Unjacketed NS75/NS90 - Full Neutral

Send link to this page print Your Nexans contact on this page
Triplex Unjacketed NS75/NS90 - Full Neutral Secondary Distribution Cable
REFERENCES
Neutral Supported Cable
Standards
Description
Characteristics
Related Information
Standards
National  CSA C22.2 N° 129
Description

Nexans’ triplex neutral supported cables consist of an assembly of two insulated phase conductors factory-cabled around a neutral conductor. The neutral conductor is the supporting member. The conductors are insulated with polyethylene (PE) rated 75 °C or crosslinked polyethylene (XLPE) rated 90 °C.

 

Application

Neutral supported cables are intended for use either as a service drop cable between a power pole and the service entrance, or as a secondary distribution cable between poles. Their use is limited to circuits not exceeding 600 volts phase-to-phase.

Triplex service drop cables are intended to deliver single-phase power from the secondary power line or pole-mounted transformer to the service entrance conductors at the user’s building or other structures.

Optional construction includes an insulated control/supply conductor.


 TOP
Characteristics
Construction characteristics
With smaller neutral conductor No  
Number of conductors 3  

 TOP
Triplex Unjacketed NS75/NS90 Full Neutral Physical Data

Code Word

Phase Conductor

Full  Size Neutral Support

Cable Assembly

Size
(Stranding)
AWG/kcmil

Diameter
(mm)

Insulation
Diameter
(mm)

Size
(Stranding)
(AWG)

Area
(mm²)

Rated
Strength
(kN)

Overall
Diameter
(mm)

Total 
Weight
(kg/km)

Jade

6 (7)

4.29

6.6

6 (6/1)

15.48

5.20

13.3

166

Ruby

4 (7)

5.41

7.8

4 (6/1)

24.71

8.14

15.6

249

Topaz

2 (7)

6.81

9.2

2 (6/1)

39.23

12.41

18.6

379

Garnet

1 (7)

7.59

10.7

1 (6/1)

49.48

15.48

21.7

493

Jasper

1/0 (7)

8.53

11.7

1/0 (6/1)

62.39

19.06

23.7

608

Diamond

2/0 (7)

9.55

12.7

2/0 (6/1)

78.65

23.80

25.9

751

Emerald

3/0 (7)

10.74

13.9

3/0 (6/1)

99.23

29.67

28.5

930

Sapphire

4/0 (7)

12.07

15.2

4/0 (6/1)

125.1

37.45

31.4

1160

-

266.8 (18)

13.64

17.8

266.8 (26/7)

157.2

50.10

37.3

1490

-

336.4 (18)

15.32

19.5

336.4 (26/7)

198.2

62.31

41.2

1850

-

397.5 (18)

16.74

20.9

397.5 (26/7)

234.2

72.65

44.3

2170

-

477 (18)

18.34

22.5

477 (26/7)

281.1

87.17

48.0

2570

-

500 (18)

18.69

22.9

500 (30/7)

312.5

109.40

49.3

2830

Code words are from the Alumimum Association Publication 50, 7th Edition, Table  C19 (add " /  XLP " suffix for NS90)
NS75 with black LLDPE (optionally MDPE) insulation, 1/c printed, 1/c no marking
NS90 with black XLPE insulation, 1/c printed, 1/c no marking
Neutral support conductors 266.8 kcmil and larger are round wire ACSR, minimum Type 16, otherwise Type 100 compact ACSR conductors are used
Overall diameter is the multiplex assembly circumscribing diameter


Triplex Unjacketed NS75/NS90 Full Neutral Electrical Data

Code
Word

Phase and
Neutral Size
(Stranding)
AWG/kcmil

Phase Conductor Resistance

Inductive
Reactance
(ohm/km)

Cable Ampacity
(amps)

Rdc @ 20ºC
(ohm/km)

Rac @ 50ºC
(ohm/km)

Rac @ 75ºC
(ohm/km)

Rac @ 90ºC
(ohm/km)

NS75

NS90

Jade

6 (7)

2.19

2.48

2.70

2.84

0.1048

80

95

Ruby

4 (7)

1.38

1.56

1.70

1.78

0.0991

105

125

Topaz

2 (7)

0.865

0.979

1.07

1.12

0.0943

140

165

Garnet

1 (7)

0.687

0.778

0.848

0.890

0.0979

160

190

Jasper

1/0 (7)

0.544

0.616

0.672

0.705

0.0955

185

220

Diamond

2/0 (7)

0.432

0.489

0.533

0.559

0.0933

210

255

Emerald

3/0 (7)

0.343

0.388

0.423

0.444

0.0912

245

290

Sapphire

4/0 (7)

0.271

0.307

0.335

0.352

0.0893

280

335

-

266.8 (18)

0.215

0.244

0.268

0.282

0.0914

325

390

-

336.4 (18)

0.171

0.193

0.215

0.225

0.0894

375

450

-

397.5 (18)

0.144

0.164

0.184

0.193

0.0881

415

500

-

477 (18)

0.121

0.136

0.155

0.163

0.0867

460

560

-

500 (18)

0.115

0.130

0.149

0.156

0.0865

500

605

Rdc at 20°C is taken from CSA C49.5
Rac at 90°C is only applicable to NS90 cable
Ampacities are from the CE Code C22.1-06, Table 36A, based on 30°C ambient air,
0.6 m/s wind, and solar radiation of 1025 W/m²


 TOP
NS75/NS90 600V Cable Construction
NS75/NS90 600 V Cable Markings
NS75/NS90 600v Optional Features


Nexans © copyright 2001 - 2012   Legal Notice | Contact Us | Site Map