Quadruplex Jacketed NS75/NS90 FT1 - Full Neutral  Secondary Distribution Cable
REFERENCES
Neutral Supported Cable
Standards
Description
Characteristics
Related Information
Standards
National  CSA C22.2 N° 129
Description

Nexans’ quadruplex neutral supported cables consist of an assembly of three insulated phase conductors factory-cabled around a neutral conductor. The neutral conductor is the supporting member. The conductors are insulated with polyethylene (PE) rated 75 °C or crosslinked polyethylene (XLPE) rated 90 °C.

 

Application

Neutral supported cables are intended for use either as a service drop cable between a power pole and the service entrance, or as a secondary distribution cable between poles. Their use is limited to circuits not exceeding 600 volts phase-to-phase.

Quadruplex service drop cable is intended to deliver three-phase power from the secondary power line or pole-mounted transformer to the service entrance conductors at the user’s building or other structure.

Optional construction includes an insulated control/supply conductor.


 TOP
Characteristics
Construction characteristics
With smaller neutral conductor No  
Number of conductors 4  

 TOP
Quadruplex Jacketed NS75/NS90 FT1, Full Neutral - Physical Data

Phase Conductor

Full Size Neutral Support

Cable Assembly

Size
(Stranding)
AWG
or kcmil

Diameter
(mm)

Jacket
Diameter
(mm)

Size
(Stranding)
AWG
or kcmil

Area
(mm2)

Rated
Strength
(kN)

Overall
Diameter
(mm)

Total 
Weight
(kg/km)

6 (7)

4.29

8.2

6 (6/1)

15.48

5.2

20.8

298

4 (7)

5.41

9.3

4 (6/1)

24.71

8.14

24

418

2 ((7)

6.81

10.7

2 (6/1)

39.23

12.41

27.9

602

1 (7)

7.59

13.1

1 (6/1)

49.48

15.48

33.7

837

1/0 (7)

8.53

14

1/0 (6/1)

62.39

19.08

36.4

1002

2/0 (7)

9.55

15

2/0 (6/1)

78.65

23.8

39.3

1204

3/0 (7)

10.74

16.2

3/0 (6/1)

99.23

29.67

42.6

1456

4/0 (7)

12.07

17.5

4/0 (6/1)

125.1

37.45

46.3

1770

266.8 (18)

13.64

20.2

266.8 (26/7)

157.2

50.1

53.7

2260

336.4 (18)

15.32

22.9

336.4 (26/7)

198.2

62.31

60.9

2905

397.5 (18)

16.74

24.3

397.5 (26/7)

234.2

72.65

64.8

3345

477 (18)

18.34

25.9

477 (26/7)

281.1

87.17

69.3

3905

500 (18)

18.69

26.2

500 (30/7)

312.5

109.4

70.6

4205

NS75 with black LLDPE (optionally MDPE) insulation, PVC jacket - 1/c black, 1/c red, 1/c blue
NS90 with black XLPE insulation, PVC jacket - 1/c black, 1/c red, 1/c blue
Neutral support conductors 266.8 kcmil and larger are round wire ACSR, minimum Type 16, otherwise Type 100 compact  ACSR conductors are used.
Overall diameter is the multiplex assembly circumsribing circle diameter


Quadruplex Jacketed NS75/NS90 FT1, Full Neutral - Electrical Data

Phase Size
(Stranding)
AWG
ou kcmil

Phase Conductor Resistance

Inductive
Reactance
(ohm/km)

Cable Ampacity (amps)

Rdc @ 20ºC
(ohm/km)

Rac @ 50ºC
(ohm/km)

Rac @ 75ºC
(ohm/km)

Rac @ 90ºC
(ohm/km)

NS75

NS90

6 (7)

2.19

2.48

2.7

2.84

0.1315

70

85

4 (7)

1.38

1.56

1.7

1.78

0.1243

95

110

2 ((7)

0.865

0.979

1.07

1.12

0.1181

125

150

1 (7)

0.687

0.778

0.848

0.89

0.1244

145

170

1/0 (7)

0.544

0.616

0.672

0.705

0.1211

165

200

2/0 (7)

0.432

0.489

0.533

0.559

0.1181

190

230

3/0 (7)

0.343

0.388

0.423

0.444

0.1152

220

265

4/0 (7)

0.271

0.307

0.335

0.352

0.1126

255

305

266.8 (18)

0.215

0.244

0.268

0.282

0.1136

290

355

336.4 (18)

0.171

0.193

0.215

0.225

0.1143

335

410

397.5 (18)

0.144

0.164

0.184

0.193

0.1122

370

455

477 (18)

0.121

0.136

0.155

0.163

0.1103

415

510

500 (18)

0.115

0.13

0.149

0.156

0.1101

450

555

Rdc at 20°C is taken from CSA C49.5
Rac at 90°C is only applicable to NS90 cable
Ampacities are from the CE Code C22.1-06, Table 36A, based on 30°C ambient air, 0.6 m/s wind, and solar radiation of 1025 W/m2


 TOP
NS75/NS90 600V Cable Construction
NS75/NS90 600 V Cable Markings
NS75/NS90 600v Optional Features