Description
Standards
National : CSA C22.2 N° 129Description
Nexans neutral supported cables consist of an assembly of one, two, or three insulated phase conductors factory cabled around a neutral conductor. The neutral conductor is the supporting member. The conductors are insulated with polyethylene (PE) rated 75°C or crosslinked polyethylene (XLPE) rated 90°C and are sunlight resistant.
Application
Neutral supported cables are intended for use either as a service drop cable between a power pole and the service entrance, or as a secondary distribution cable between poles. Their use is limited to circuits not exceeding 600 volts phase-to-phase.
Duplex and triplex service drop cables are intended to deliver single-phase power from the secondary power line or pole-mounted transformer to the service entrance conductors at the user’s building or other structures. Quadruplex service drop cable is intended to deliver three-phase power from the secondary power line or pole-mounted transformer to the service entrance conductors at the user’s building or other structure.
Optional construction includes an insulated control/supply conductor.
Cables supplied with an optional flame retardant PVC jacket over the insulation are suitable for applications requiring an FT1 rating.
Characteristics
Construction characteristics | |
---|---|
Insulation | PE or XLPE |
Electrical characteristics | |
Maximum operating voltage | 600V |
Specific characteristics | |
See all products | |
|
Products and services
Docs and info
Duplex Jacketed NS75/NS90 FT1 Electrical Data
Phase Size |
Phase Conductor Resistance |
Inductive |
Cable Ampacity |
||||
Rdc @ 20ºC |
Rac @ 50ºC |
Rac @ 75ºC |
Rac @ 90ºC |
NS75 |
NS90 |
||
6 (7) |
2.19 |
2.48 |
2.70 |
2.84 |
0.1207 |
80 |
95 |
4 (7) |
1.38 |
1.56 |
1.70 |
1.78 |
0.1129 |
105 |
125 |
2 (7) |
0.865 |
0.979 |
1.07 |
1.12 |
0.1061 |
140 |
165 |
1 (7) |
0.687 |
0.778 |
0.848 |
0.890 |
0.1129 |
160 |
190 |
1/0 (7) |
0.544 |
0.616 |
0.672 |
0.705 |
0.1093 |
185 |
220 |
2/0 (7) |
0.432 |
0.489 |
0.533 |
0.559 |
0.1061 |
210 |
255 |
3/0 (7) |
0.343 |
0.388 |
0.423 |
0.444 |
0.1030 |
245 |
290 |
4/0 (7) |
0.271 |
0.307 |
0.335 |
0.352 |
0.1001 |
280 |
335 |
266.8 (18) |
0.215 |
0.244 |
0.268 |
0.282 |
0.1007 |
325 |
390 |
336.4 (18) |
0.171 |
0.193 |
0.215 |
0.225 |
0.1015 |
375 |
450 |
397.5 (18) |
0.144 |
0.164 |
0.184 |
0.193 |
0.0993 |
415 |
500 |
477 (18) |
0.121 |
0.136 |
0.155 |
0.163 |
0.0973 |
460 |
560 |
500 (18) |
0.115 |
0.130 |
0.149 |
0.156 |
0.0968 |
500 |
605 |
Rdc at 20°C is taken from CSA C49.5 |
Duplex Jacketed NS75/NS90 FT1 Physical Data
Phase Conductor |
Full Size Neutral Support |
Cable Assembly |
|||||
Size |
Diameter |
Jacket |
Size |
Area |
Rated |
Overall |
Total |
6 (7) |
4.29 |
8.2 |
6 (6/1) |
15.48 |
5.20 |
12.8 |
135 |
4 (7) |
5.41 |
9.3 |
4 (6/1) |
24.71 |
8.14 |
15.1 |
196 |
2 (7) |
6.81 |
10.7 |
2 (6/1) |
39.23 |
12.41 |
18.1 |
291 |
1 (7) |
7.59 |
13.1 |
1 (6/1) |
49.48 |
15.48 |
21.3 |
393 |
1/0 (7) |
8.53 |
14.0 |
1/0 (6/1) |
62.39 |
19.08 |
23.3 |
478 |
2/0 (7) |
9.55 |
15.0 |
2/0 (6/1) |
78.65 |
23.80 |
25.4 |
583 |
3/0 (7) |
10.74 |
16.2 |
3/0 (6/1) |
99.23 |
29.67 |
27.9 |
714 |
4/0 (7) |
12.07 |
17.5 |
4/0 (6/1) |
125.1 |
37.45 |
30.7 |
879 |
266.8 (18) |
13.64 |
20.2 |
266.8 (26/7) |
157.2 |
50.10 |
36.4 |
1117 |
336.4 (18) |
15.32 |
22.9 |
336.4 (26/7) |
198.2 |
62.31 |
41.2 |
1427 |
397.5 (18) |
16.74 |
24.3 |
397.5 (26/7) |
234.2 |
72.65 |
44.2 |
1657 |
477 (18) |
18.34 |
25.9 |
477 (26/7) |
281.1 |
87.17 |
47.7 |
1951 |
500 (18) |
18.69 |
26.2 |
500 (30/7) |
312.5 |
109.40 |
49.2 |
2176 |
NS75 with black LLDPE (optionally MDPE) insulation, black PVC jacket |
NS75/NS90 Duplex Unjacketed Physical Data
|
Phase Conductor |
Full Size Neutral Support |
Cable Assembly |
|||||
Code Word |
Size |
Diameter |
Insulation |
Size |
Area |
Rated |
Overall |
Total |
Arcturus |
6 (7) |
4.29 |
6.6 |
6 (6/1) |
15.48 |
5.20 |
11.3 |
112 |
Castor |
4 (7) |
5.41 |
7.8 |
4 (6/1) |
24.71 |
8.14 |
13.6 |
170 |
Deneb |
2 ((7) |
6.81 |
9.2 |
2 (6/1) |
39.23 |
12.40 |
16.5 |
260 |
- |
1 (7) |
7.59 |
10.7 |
1 (6/1) |
49.48 |
15.50 |
19.1 |
335 |
Vega |
1/0 (7) |
8.53 |
11.7 |
1/0 (6/1) |
62.39 |
19.10 |
21.1 |
420 |
- |
2/0 (7) |
9.55 |
12.7 |
2/0 (6/1) |
78.65 |
23.80 |
23.2 |
520 |
- |
3/0 (7) |
10.74 |
13.9 |
3/0 (6/1) |
99.23 |
29.70 |
25.7 |
650 |
- |
4/0 (7) |
12.07 |
15.2 |
4/0 (6/1) |
125.10 |
37.50 |
28.4 |
810 |
- |
266.8 (18) |
13.64 |
17.8 |
266.8 (26/7) |
157.20 |
50.10 |
34.1 |
1019 |
- |
336.4 (18) |
15.32 |
19.5 |
336.4 (26/7) |
198.20 |
62.31 |
37.8 |
1270 |
- |
397.5 (18) |
16.74 |
20.9 |
397.5 (26/7) |
234.20 |
72.65 |
40.8 |
1490 |
- |
477 (18) |
18.34 |
22.5 |
477 (26/7) |
281.10 |
87.17 |
44.3 |
1772 |
- |
500 (18) |
18.69 |
22.9 |
500 (30/7) |
312.50 |
109.40 |
45.8 |
1995 |
Code words are from the Aluminum Association Publication 50, 7th Edition, Table C17 (add " / XLP " suffix for NS90) |
NS75/NS90 Duplex Unjacketed Electrical Data
Code |
Phase Size |
Phase Conductor Resistance |
Inductive |
Cable Ampacity (amps) |
||||
Rdc @ 20ºC |
Rac @ 50ºC |
Rac @ 75ºC |
Rac @ 90ºC |
NS75 |
NS90 |
|||
Arcturus |
6 (7) |
2.190 |
2.480 |
2.700 |
2.840 |
0.1048 |
80 |
95 |
Castor |
4 (7) |
1.380 |
1.560 |
1.700 |
1.780 |
0.0991 |
105 |
125 |
Deneb |
2 ((7) |
0.865 |
0.979 |
1.070 |
1.120 |
0.0943 |
140 |
165 |
- |
1 (7) |
0.687 |
0.778 |
0.848 |
0.890 |
0.0979 |
160 |
190 |
Vega |
1/0 (7) |
0.544 |
0.616 |
0.672 |
0.705 |
0.0955 |
185 |
220 |
- |
2/0 (7) |
0.432 |
0.489 |
0.533 |
0.559 |
0.0933 |
210 |
255 |
- |
3/0 (7) |
0.343 |
0.388 |
0.423 |
0.444 |
0.0912 |
245 |
290 |
- |
4/0 (7) |
0.271 |
0.307 |
0.335 |
0.352 |
0.0893 |
280 |
335 |
- |
266.8 (18) |
0.215 |
0.244 |
0.268 |
0.282 |
0.0914 |
325 |
390 |
- |
336.4 (18) |
0.171 |
0.193 |
0.215 |
0.225 |
0.0894 |
375 |
450 |
- |
397.5 (18) |
0.144 |
0.164 |
0.184 |
0.193 |
0.0881 |
415 |
500 |
- |
477 (18) |
0.121 |
0.136 |
0.155 |
0.163 |
0.0867 |
460 |
560 |
- |
500 (18) |
0.115 |
0.130 |
0.149 |
0.156 |
0.0865 |
500 |
605 |
Rdc at 20°C is taken from CSA C49.5 |
Triplex Jacketed NS75/NS90 FT1 Full Neutral Electrical Data
Phase Size |
Phase Conductor Resistance |
Inductive |
Cable Ampacity |
||||
Rdc @ 20ºC |
Rac @ 50ºC |
Rac @ 75ºC |
Rac @ 90ºC |
NS75 |
NS90 |
||
6 (7) |
2.19 |
2.48 |
2.70 |
2.84 |
0.1207 |
80 |
95 |
4 (7) |
1.38 |
1.56 |
1.70 |
1.78 |
0.1129 |
105 |
125 |
2 (7) |
0.865 |
0.979 |
1.07 |
1.12 |
0.1061 |
140 |
165 |
1 (7) |
0.687 |
0.778 |
0.848 |
0.890 |
0.1129 |
160 |
190 |
1/0 (7) |
0.544 |
0.616 |
0.672 |
0.705 |
0.1093 |
185 |
220 |
2/0 (7) |
0.432 |
0.489 |
0.533 |
0.559 |
0.1061 |
210 |
255 |
3/0 (7) |
0.343 |
0.388 |
0.423 |
0.444 |
0.1030 |
245 |
290 |
4/0 (7) |
0.271 |
0.307 |
0.335 |
0.352 |
0.1001 |
280 |
335 |
266.8 (18) |
0.215 |
0.244 |
0.268 |
0.282 |
0.1007 |
325 |
390 |
336.4 (18) |
0.171 |
0.193 |
0.215 |
0.225 |
0.1015 |
375 |
450 |
397.5 (18) |
0.144 |
0.164 |
0.184 |
0.193 |
0.0993 |
415 |
500 |
477 (18) |
0.121 |
0.136 |
0.155 |
0.163 |
0.0973 |
460 |
560 |
500 (18) |
0.115 |
0.130 |
0.149 |
0.156 |
0.0968 |
500 |
605 |
Rdc at 20°C is taken from CSA C49.5 |
Triplex Jacketed NS75/NS90 FT1 Full Neutral Physical Data
Phase Conductor |
Full Size Neutral Support |
Cable Assembly |
|||||
Size |
Diameter |
Jacket |
Size |
Area |
Rated |
Overall |
Total |
6 (7) |
4.29 |
8.2 |
6 (6/1) |
15.48 |
5.20 |
16.4 |
217 |
4 (7) |
5.41 |
9.3 |
4 (6/1) |
24.71 |
8.14 |
18.6 |
307 |
2 (7) |
6.81 |
10.7 |
2 (6/1) |
39.23 |
12.41 |
21.4 |
446 |
1 (7) |
7.59 |
13.1 |
1 (6/1) |
49.48 |
15.48 |
26.1 |
615 |
1/0 (7) |
8.53 |
14.0 |
1/0 (6/1) |
62.39 |
19.08 |
28.0 |
740 |
2/0 (7) |
9.55 |
15.0 |
2/0 (6/1) |
78.65 |
23.80 |
30.1 |
894 |
3/0 (7) |
10.74 |
16.2 |
3/0 (6/1) |
99.23 |
29.67 |
32.5 |
1090 |
4/0 (7) |
12.07 |
17.5 |
4/0 (6/1) |
125.1 |
37.45 |
35.3 |
1320 |
266.8 (18) |
13.64 |
20.2 |
266.8 (26/7) |
157.2 |
50.10 |
41.1 |
1690 |
336.4 (18) |
15.32 |
22.9 |
336.4 (26/7) |
198.2 |
62.31 |
46.5 |
2170 |
397.5 (18) |
16.74 |
24.3 |
397.5 (26/7) |
234.2 |
72.65 |
49.6 |
2500 |
477 (18) |
18.34 |
25.9 |
477 (26/7) |
281.1 |
87.17 |
53.2 |
2930 |
500 (18) |
18.69 |
26.2 |
500 (30/7) |
312.5 |
109.40 |
54.4 |
3190 |
NS75 with black LLDPE (optionally MDPE) insulation, PVC jacket - 1/c black, 1/c red |
Triplex Jacketed NS75/NS90 FT1 Reduced Neutral Physical Data
Phase Conductor |
Reduced Size Neutral Support |
Cable Assembly |
|||||
Size |
Diameter |
Jacket |
Size |
Area |
Rated |
Overall |
Total |
4 (7) |
5.41 |
9.3 |
6 (6/1) |
15.48 |
5.20 |
18.6 |
275 |
2 (7) |
6.81 |
10.7 |
4 (6/1) |
24.71 |
8.14 |
21.4 |
396 |
1 (7) |
7.59 |
13.1 |
2 (6/1) |
39.23 |
12.41 |
26.1 |
580 |
1/0 (7) |
8.53 |
14.0 |
2 (6/1) |
39.23 |
12.41 |
28.0 |
660 |
2/0 (7) |
9.55 |
15.0 |
1 (6/1) |
49.48 |
15.48 |
30.0 |
792 |
3/0 (7) |
10.74 |
16.2 |
1/0 (6/1) |
62.39 |
19.08 |
32.4 |
960 |
4/0 (7) |
12.07 |
17.5 |
2/0 (6/1) |
78.65 |
23.80 |
35.1 |
1160 |
266.8 (18) |
13.64 |
20.2 |
3/0 (6/1) |
99.2 |
29.67 |
40.3 |
1490 |
336.4 (18) |
15.32 |
22.9 |
4/0 (6/1) |
125.1 |
37.45 |
45.7 |
1910 |
397.5 (18) |
16.74 |
24.3 |
266.8 (26/7) |
157.2 |
50.10 |
48.6 |
2230 |
477 (18) |
18.34 |
25.9 |
336.4 (26/7) |
198.2 |
62.31 |
51.9 |
2640 |
500 (18) |
18.69 |
26.2 |
397.5 (26/7) |
234.2 |
72.65 |
52.9 |
2840 |
NS75 with black LLDPE (optionally MDPE) insulation, PVC jacket - 1/c black, 1/c red |
Triplex Jacketed NS75/NS90 FT1 Reduced Neutral Electrical Data
Phase Size |
Neutral |
Phase Conductor Resistance |
Inductive |
Cable |
||||
Rdc @ 20ºC |
Rac @ 50ºC |
Rac @ 75ºC |
Rac @ 90ºC |
NS75 |
NS90 |
|||
4 (7) |
6 (6/1) |
1.38 |
1.56 |
1.70 |
1.78 |
0.1129 |
105 |
125 |
2 (7) |
4 (6/1) |
0.865 |
0.979 |
1.07 |
1.12 |
0.1061 |
140 |
165 |
1 (7) |
2 (6/1) |
0.687 |
0.778 |
0.848 |
0.890 |
0.1129 |
160 |
190 |
1/0 (7) |
2 (6/1) |
0.544 |
0.616 |
0.672 |
0.705 |
0.1093 |
185 |
220 |
2/0 (7) |
1 (6/1) |
0.432 |
0.489 |
0.533 |
0.559 |
0.1061 |
210 |
255 |
3/0 (7) |
1/0 (6/1) |
0.343 |
0.388 |
0.423 |
0.444 |
0.1030 |
245 |
290 |
4/0 (7) |
2/0 (6/1) |
0.271 |
0.307 |
0.335 |
0.352 |
0.1001 |
280 |
335 |
266.8 (18) |
3/0 (6/1) |
0.215 |
0.244 |
0.268 |
0.282 |
0.1007 |
325 |
390 |
336.4 (18) |
4/0 (6/1) |
0.171 |
0.193 |
0.215 |
0.225 |
0.1015 |
375 |
450 |
397.5 (18) |
266.8 (26/7) |
0.144 |
0.164 |
0.184 |
0.193 |
0.0993 |
415 |
500 |
477 (18) |
336.4 (26/7) |
0.121 |
0.136 |
0.155 |
0.163 |
0.0973 |
460 |
560 |
500 (18) |
397.5 (26/7) |
0.115 |
0.130 |
0.149 |
0.156 |
0.0968 |
500 |
605 |
Rdc at 20°C is taken from CSA C49.5 |
Triplex Unjacketed NS75/NS90 Full Neutral Physical Data
Code Word |
Phase Conductor |
Full Size Neutral Support |
Cable Assembly |
|||||
Size |
Diameter |
Insulation |
Size |
Area |
Rated |
Overall |
Total |
|
Jade |
6 (7) |
4.29 |
6.6 |
6 (6/1) |
15.48 |
5.20 |
13.3 |
166 |
Ruby |
4 (7) |
5.41 |
7.8 |
4 (6/1) |
24.71 |
8.14 |
15.6 |
249 |
Topaz |
2 (7) |
6.81 |
9.2 |
2 (6/1) |
39.23 |
12.41 |
18.6 |
379 |
Garnet |
1 (7) |
7.59 |
10.7 |
1 (6/1) |
49.48 |
15.48 |
21.7 |
493 |
Jasper |
1/0 (7) |
8.53 |
11.7 |
1/0 (6/1) |
62.39 |
19.06 |
23.7 |
608 |
Diamond |
2/0 (7) |
9.55 |
12.7 |
2/0 (6/1) |
78.65 |
23.80 |
25.9 |
751 |
Emerald |
3/0 (7) |
10.74 |
13.9 |
3/0 (6/1) |
99.23 |
29.67 |
28.5 |
930 |
Sapphire |
4/0 (7) |
12.07 |
15.2 |
4/0 (6/1) |
125.1 |
37.45 |
31.4 |
1160 |
- |
266.8 (18) |
13.64 |
17.8 |
266.8 (26/7) |
157.2 |
50.10 |
37.3 |
1490 |
- |
336.4 (18) |
15.32 |
19.5 |
336.4 (26/7) |
198.2 |
62.31 |
41.2 |
1850 |
- |
397.5 (18) |
16.74 |
20.9 |
397.5 (26/7) |
234.2 |
72.65 |
44.3 |
2170 |
- |
477 (18) |
18.34 |
22.5 |
477 (26/7) |
281.1 |
87.17 |
48.0 |
2570 |
- |
500 (18) |
18.69 |
22.9 |
500 (30/7) |
312.5 |
109.40 |
49.3 |
2830 |
Code words are from the Alumimum Association Publication 50, 7th Edition, Table C19 (add " / XLP " suffix for NS90) |
Triplex Unjacketed NS75/NS90 Full Neutral Electrical Data
Code |
Phase and |
Phase Conductor Resistance |
Inductive |
Cable Ampacity |
||||
Rdc @ 20ºC |
Rac @ 50ºC |
Rac @ 75ºC |
Rac @ 90ºC |
NS75 |
NS90 |
|||
Jade |
6 (7) |
2.19 |
2.48 |
2.70 |
2.84 |
0.1048 |
80 |
95 |
Ruby |
4 (7) |
1.38 |
1.56 |
1.70 |
1.78 |
0.0991 |
105 |
125 |
Topaz |
2 (7) |
0.865 |
0.979 |
1.07 |
1.12 |
0.0943 |
140 |
165 |
Garnet |
1 (7) |
0.687 |
0.778 |
0.848 |
0.890 |
0.0979 |
160 |
190 |
Jasper |
1/0 (7) |
0.544 |
0.616 |
0.672 |
0.705 |
0.0955 |
185 |
220 |
Diamond |
2/0 (7) |
0.432 |
0.489 |
0.533 |
0.559 |
0.0933 |
210 |
255 |
Emerald |
3/0 (7) |
0.343 |
0.388 |
0.423 |
0.444 |
0.0912 |
245 |
290 |
Sapphire |
4/0 (7) |
0.271 |
0.307 |
0.335 |
0.352 |
0.0893 |
280 |
335 |
- |
266.8 (18) |
0.215 |
0.244 |
0.268 |
0.282 |
0.0914 |
325 |
390 |
- |
336.4 (18) |
0.171 |
0.193 |
0.215 |
0.225 |
0.0894 |
375 |
450 |
- |
397.5 (18) |
0.144 |
0.164 |
0.184 |
0.193 |
0.0881 |
415 |
500 |
- |
477 (18) |
0.121 |
0.136 |
0.155 |
0.163 |
0.0867 |
460 |
560 |
- |
500 (18) |
0.115 |
0.130 |
0.149 |
0.156 |
0.0865 |
500 |
605 |
Rdc at 20°C is taken from CSA C49.5 |
Triplex Unjacketed NS75/NS90 Reduced Neutral Physical Data
Code Word |
Phase Conductor |
Reduced Size Neutral Support |
Cable Assembly |
|||||
Size |
Diameter |
Insulation |
Size |
Area |
Rated |
Overall |
Total |
|
Caesium |
4 (7) |
5.41 |
7.8 |
6 (6/1) |
15.48 |
5.20 |
15.5 |
217 |
Indium |
2 (7) |
6.81 |
9.2 |
4 (6/1) |
24.71 |
8.14 |
18.3 |
328 |
- |
1 (7) |
7.59 |
10.7 |
2 (6/1) |
39.23 |
8.14 |
21.4 |
457 |
Rubidium |
1/0 (7) |
8.53 |
11.7 |
2 (6/1) |
39.23 |
12.41 |
23.3 |
528 |
Titanium |
2/0 (7) |
9.55 |
12.7 |
1 (6/1) |
49.48 |
15.48 |
25.3 |
650 |
Palladium |
3/0 (7) |
10.74 |
13.9 |
1/0 (6/1) |
62.39 |
19.08 |
27.7 |
800 |
Strontium |
4/0 (7) |
12.07 |
15.2 |
2/0 (6/1) |
78.65 |
23.80 |
30.4 |
1000 |
- |
266.8 (18) |
13.64 |
17.8 |
3/0 (6/1) |
99.23 |
29.67 |
35.6 |
1290 |
- |
336.4 (18) |
15.32 |
19.5 |
4/0 (6/1) |
125.1 |
37.45 |
39.0 |
1600 |
- |
397.5 (18) |
16.74 |
20.9 |
266.8 (26/7) |
157.2 |
50.10 |
42.3 |
1900 |
- |
477 (18) |
18.34 |
22.5 |
336.4 (26/7) |
198.2 |
62.31 |
45.9 |
2280 |
- |
500 (18) |
18.69 |
22.9 |
397.5 (26/7) |
234.2 |
72.65 |
47.3 |
2480 |
Code words are from the Aluminum Association Publication 50, 7th Edition, Table C20 (add " / XLP " suffix for NS90) |
Triplex Unjacketed NS75/NS90 Reduced Neutral Electrical Data
Code |
Phase Size |
Neutral |
Phase Conductor Resistance |
Inductive |
Cable |
||||
Rdc @ 20ºC |
Rac @ 50ºC |
Rac @ 75ºC |
Rac @ 90ºC |
NS75 |
NS90 |
||||
Caesium |
4 (7) |
6 (6/1) |
1.38 |
1.56 |
1.70 |
1.78 |
0.0991 |
105 |
125 |
Indium |
2 (7) |
4 (6/1) |
0.865 |
0.979 |
1.07 |
1.12 |
0.0943 |
140 |
165 |
- |
1 (7) |
2 (6/1) |
0.687 |
0.778 |
0.848 |
0.890 |
0.0979 |
160 |
190 |
Rubidium |
1/0 (7) |
2 (6/1) |
0.544 |
0.616 |
0.672 |
0.705 |
0.0955 |
185 |
220 |
Titanium |
2/0 (7) |
1 (6/1) |
0.432 |
0.489 |
0.533 |
0.559 |
0.0933 |
210 |
255 |
Palladium |
3/0 (7) |
1/0 (6/1) |
0.343 |
0.388 |
0.423 |
0.444 |
0.0912 |
245 |
290 |
Strontium |
4/0 (7) |
2/0 (6/1) |
0.271 |
0.307 |
0.335 |
0.352 |
0.0893 |
280 |
335 |
- |
266.8 (18) |
3/0 (6/1) |
0.215 |
0.244 |
0.268 |
0.282 |
0.0914 |
325 |
390 |
- |
336.4 (18) |
4/0 (6/1) |
0.171 |
0.193 |
0.215 |
0.225 |
0.0894 |
375 |
450 |
- |
397.5 (18) |
266.8 (26/7) |
0.144 |
0.164 |
0.184 |
0.193 |
0.0881 |
415 |
500 |
- |
477 (18) |
336.4 (26/7) |
0.121 |
0.136 |
0.155 |
0.163 |
0.0867 |
460 |
560 |
- |
500 (18) |
397.5 (26/7) |
0.115 |
0.130 |
0.149 |
0.156 |
0.0865 |
500 |
605 |
Rdc at 20°C is taken from CSA C49.5 |
Quadruplex Jacketed NS75/NS90 FT1 Full Neutral Physical Data
Phase Conductor |
Full Size Neutral Support |
Cable Assembly |
|||||
Size |
Diameter |
Jacket |
Size |
Area |
Rated |
Overall |
Total |
6 (7) |
4.29 |
8.2 |
6 (6/1) |
15.48 |
5.2 |
20.8 |
298 |
4 (7) |
5.41 |
9.3 |
4 (6/1) |
24.71 |
8.14 |
24 |
418 |
2 (7) |
6.81 |
10.7 |
2 (6/1) |
39.23 |
12.41 |
27.9 |
602 |
1 (7) |
7.59 |
13.1 |
1 (6/1) |
49.48 |
15.48 |
33.7 |
837 |
1/0 (7) |
8.53 |
14 |
1/0 (6/1) |
62.39 |
19.08 |
36.4 |
1002 |
2/0 (7) |
9.55 |
15 |
2/0 (6/1) |
78.65 |
23.8 |
39.3 |
1204 |
3/0 (7) |
10.74 |
16.2 |
3/0 (6/1) |
99.23 |
29.67 |
42.6 |
1456 |
4/0 (7) |
12.07 |
17.5 |
4/0 (6/1) |
125.1 |
37.45 |
46.3 |
1770 |
266.8 (18) |
13.64 |
20.2 |
266.8 (26/7) |
157.2 |
50.1 |
53.7 |
2260 |
336.4 (18) |
15.32 |
22.9 |
336.4 (26/7) |
198.2 |
62.31 |
60.9 |
2905 |
397.5 (18) |
16.74 |
24.3 |
397.5 (26/7) |
234.2 |
72.65 |
64.8 |
3345 |
477 (18) |
18.34 |
25.9 |
477 (26/7) |
281.1 |
87.17 |
69.3 |
3905 |
500 (18) |
18.69 |
26.2 |
500 (30/7) |
312.5 |
109.4 |
70.6 |
4205 |
NS75 with black LLDPE (optionally MDPE) insulation, PVC jacket - 1/c black, 1/c red, 1/c blue |
Quadruplex Jacketed NS75/NS90 FT1 Full Neutral Electrical Data
Phase Size |
Phase Conductor Resistance |
Inductive |
Cable Ampacity (amps) |
||||
Rdc @ 20ºC |
Rac @ 50ºC |
Rac @ 75ºC |
Rac @ 90ºC |
NS75 |
NS90 |
||
6 (7) |
2.19 |
2.48 |
2.7 |
2.84 |
0.1315 |
70 |
85 |
4 (7) |
1.38 |
1.56 |
1.7 |
1.78 |
0.1243 |
95 |
110 |
2 (7) |
0.865 |
0.979 |
1.07 |
1.12 |
0.1181 |
125 |
150 |
1 (7) |
0.687 |
0.778 |
0.848 |
0.89 |
0.1244 |
145 |
170 |
1/0 (7) |
0.544 |
0.616 |
0.672 |
0.705 |
0.1211 |
165 |
200 |
2/0 (7) |
0.432 |
0.489 |
0.533 |
0.559 |
0.1181 |
190 |
230 |
3/0 (7) |
0.343 |
0.388 |
0.423 |
0.444 |
0.1152 |
220 |
265 |
4/0 (7) |
0.271 |
0.307 |
0.335 |
0.352 |
0.1126 |
255 |
305 |
266.8 (18) |
0.215 |
0.244 |
0.268 |
0.282 |
0.1136 |
290 |
355 |
336.4 (18) |
0.171 |
0.193 |
0.215 |
0.225 |
0.1143 |
335 |
410 |
397.5 (18) |
0.144 |
0.164 |
0.184 |
0.193 |
0.1122 |
370 |
455 |
477 (18) |
0.121 |
0.136 |
0.155 |
0.163 |
0.1103 |
415 |
510 |
500 (18) |
0.115 |
0.13 |
0.149 |
0.156 |
0.1101 |
450 |
555 |
Rdc at 20°C is taken from CSA C49.5 |
Quadruplex Unjacketed NS75/NS90 Full Neutral Electrical Data
Code |
Phase and |
Phase Conductor Resistance |
Inductive |
Cable Ampacity |
||||
Rdc @ 20ºC |
Rac @ 50ºC |
Rac @ 75ºC |
Rac @ 90ºC |
NS75 |
NS90 |
|||
Aqua |
6 (7) |
2.19 |
2.48 |
2.70 |
2.84 |
0.1169 |
70 |
85 |
Libra |
4 (7) |
1.38 |
1.56 |
1.70 |
1.78 |
0.1116 |
95 |
110 |
Capricornus |
2 (7) |
0.865 |
0.979 |
1.07 |
1.12 |
0.1071 |
125 |
150 |
- |
1 (7) |
0.687 |
0.778 |
0.848 |
0.890 |
0.1105 |
145 |
170 |
Pisces |
1/0 (7) |
0.544 |
0.616 |
0.672 |
0.705 |
0.1082 |
165 |
200 |
Aries |
2/0 (7) |
0.432 |
0.489 |
0.533 |
0.559 |
0.1062 |
190 |
230 |
Taurus |
3/0 (7) |
0.343 |
0.388 |
0.423 |
0.444 |
0.1042 |
220 |
265 |
Gemini |
4/0 (7) |
0.271 |
0.307 |
0.335 |
0.352 |
0.1025 |
255 |
305 |
- |
266.8 (18) |
0.215 |
0.244 |
0.268 |
0.282 |
0.1048 |
290 |
355 |
- |
336.4 (18) |
0.171 |
0.193 |
0.215 |
0.225 |
0.1030 |
335 |
410 |
- |
397.5 (18) |
0.144 |
0.164 |
0.184 |
0.193 |
0.1016 |
370 |
455 |
- |
477 (18) |
0.121 |
0.136 |
0.155 |
0.163 |
0.1004 |
415 |
510 |
- |
500 (18) |
0.115 |
0.130 |
0.149 |
0.156 |
0.1003 |
450 |
555 |
Rdc at 20°C is taken from CSA C49.5 |
Quadruplex Unjacketed NS75/NS90 Full Neutral Physical Data
Code Word |
Phase Conductor |
Full Size Neutral Support |
Cable Assembly |
|||||
Size |
Diameter |
Insulation |
Size |
Area |
Rated |
Overall |
Total |
|
Aqua |
6 (7) |
4.29 |
6.6 |
6 (6/1) |
15.48 |
5.20 |
17.4 |
222 |
Libra |
4 (7) |
5.41 |
7.8 |
4 (6/1) |
24.71 |
8.14 |
20.5 |
331 |
Capricornus |
2 (7) |
6.81 |
9.2 |
2 (6/1) |
39.23 |
12.41 |
24.4 |
500 |
- |
1 (7) |
7.59 |
10.7 |
1 (6/1) |
49.48 |
15.48 |
28.4 |
653 |
Pisces |
1/0 (7) |
8.53 |
11.7 |
1/0 (6/1) |
62.39 |
19.08 |
31.0 |
804 |
Aries |
2/0 (7) |
9.55 |
12.7 |
2/0 (6/1) |
78.65 |
23.80 |
33.9 |
990 |
Taurus |
3/0 (7) |
10.74 |
13.9 |
3/0 (6/1) |
99.23 |
29.67 |
37.2 |
1224 |
Gemini |
4/0 (7) |
12.07 |
15.2 |
4/0 (6/1) |
125.1 |
37.45 |
40.8 |
1517 |
- |
266.8 (18) |
13.64 |
17.8 |
266.8 (26/7) |
157.2 |
50.10 |
48.2 |
1967 |
- |
336.4 (18) |
15.32 |
19.5 |
336.4 (26/7) |
198.2 |
62.31 |
52.9 |
2435 |
- |
397.5 (18) |
16.74 |
20.9 |
397.5 (26/7) |
234.2 |
72.65 |
56.8 |
2844 |
- |
477 (18) |
18.34 |
22.5 |
477 (26/7) |
281.1 |
87.17 |
61.3 |
3368 |
- |
500 (18) |
18.69 |
22.9 |
500 (30/7) |
312.5 |
109.40 |
62.5 |
3660 |
Code words are from the Aluminum Association Publication 50, 7th Edition, Table C17 (add " / XLP " suffix for NS90) |
-
ACSR, ASC Description
ACSR
ACSR is a composite concentric-lay-stranded conductor consisting of a central steel core around which are stranded one or more layers of aluminum alloy 1350-H19 wires. The steel core may consist of a single wire, 7, 19, 37 or more concentrically stranded wires. The steel wires are normally protected against corrosion by a zinc coating. The standard Class A coating is usually adequate for ordinary environments. Heavier Class B or Class C coatings may be specified for greater protection. A special high-strength steel core with a Class A coating is also available.
Features and Benefits:
ACSR conductors have a long service record due to their economy, dependability and favourable strength to weight ratio. Such conductors combine the light weight and high conductivity of the aluminum wires with the tensile strength and ruggedness of the steel core. For overhead line design, this enables higher tensions to be used with less conductor sag and longer spans than would be possible with most other types of conductors.
ASC
Bare overhead aluminum stranded conductors (ASC) are concentric-lay-stranded consisting of one or more layers of aluminum alloy 1350 wires wrapped helically around a central wire. Each successive layer has six wires more than the underlying one. Increasing the number of wires for any given cross-sectional area provides greater flexibility. The most commonly used strandings consist of 7, 19, 37, 61 and 91 wires.
Class AA strandings are used for bare overhead lines. The direction of lay for the outer layer is right-hand and is usually reversed in successive layers. The temper of the wires is full hard-drawn (H19).
Features and Benefits:
ASC conductors are the most economical since their lighter weight means lower unit length costs, easier handling during installation and the use of simpler fittings. They are inherently corrosion resistant due to their homogeneous construction
Applications
ACSR
Aluminum conductors, steel reinforced (ACSR) are widely used for overhead transmission and distribution lines.
ASC
Stranded bare ASC conductors may be used in overhead line installations where the design parameters do not require the higher tensile strength or temperature ratings provided by ACSR, ACCR or other types of conductors - NS75/NS90 600 V Cable Construction
- NS75/NS90 600 V Cable Markings