Description
Standards
National : CSA C22.2 N° 123Description
Compact ACM aluminum conductors with EXELENE® cross-linked polyethylene insulation (RW90 XLPE) enclosed in a liquid- and vapour-tight solid corrugated aluminum sheath. An overall sunlight resistant, low temperature, low acid gas and low flame spread (LAG/LFS) PVC jacket with FT4 and AG14 rating.
Unjacketed CORFLEX® with FT4 and AG14 ratings is also available.
Rated 600 volts. LEAD FREE and RoHS compliant.
CSA File #LL19376 Class 5812 01 - Cable
CSA File #LL19376 Class 5818 01 - Hazardous Location Cable Application
Application
- For exposed and concealed wiring in dry or wet locations and where exposed to the weather. Nexans cables are marked "SUN RES" for sunlight resistant.
- For use in ventilated, non-ventilated, and ladder type cabletroughs and ventilated flexible cableways in dry or wet locations.
- For direct earth burial (with protection as required by Inspection Authority). For direct embedding in concrete, masonry or plaster (with permission as required by Local Inspection Authority).
- For service entrance above or below ground.
CORFLEX® cable is certified for use in hazardous locations with approved connectors. Nexans Canada Type W connector are approved for Class II Divisions 1 and 2 (Groups E, F and G) and Class III Divisions 1 and 2.
Versatile
- Reduced material handling required for installation
- Reduced cable splices as can transition between applications in buldings, outdoors and undergroud
- Reduced physical supports as hand-trainable and maintains shape
- Ideal for larger circuits 1000 amps and more
- Suitable for direct burial or concrete encasement
- Fire resistant for 1 to 2 hours when embedded in concrete
- Cost-effective alternative to bus duct or cable bus
Characteristics
Construction characteristics | |
---|---|
Insulation | XLPE |
Electrical characteristics | |
Maximum operating voltage | 600V |
Usage characteristics | |
Maximum operating temperature | 90°C |
Specific characteristics | |
See all products | |
|
Products and services
Docs and info
CORFLEX® SINGLE ALUMINUM CONDUCTOR**
Size AWG |
Approximate Diameter |
Approx Net Cable Weight |
Connectors |
Minimum† |
Ampacity |
||||||||
Over Sheath |
Over PVC |
Without Jacket |
With PVC |
||||||||||
mm |
in |
mm |
in |
kg/km |
lbs/kft |
kg/km |
lbs/kft |
Dry |
Wet |
mm |
in |
||
1/0 |
19.1 |
0.75 |
21.8 |
0.86 |
331 |
223 |
454 |
305 |
20D3 |
20W3 |
229 |
9.0 |
190 |
2/0 |
19.6 |
0.77 |
22.4 |
0.88 |
380 |
255 |
506 |
340 |
20D3 |
20W3 |
235 |
9.3 |
220 |
3/0 |
20.3 |
0.80 |
23.1 |
0.91 |
435 |
292 |
566 |
380 |
20D3 |
20W3 |
243 |
9.5 |
255 |
4/0 |
20.8 |
0.82 |
23.4 |
0.92 |
497 |
334 |
640 |
430 |
20D3 |
20W3 |
246 |
9.7 |
300 |
250 |
24.1 |
0.95 |
26.9 |
1.06 |
604 |
406 |
759 |
510 |
25D3 |
25W3 |
282 |
11.1 |
330 |
300 |
25.1 |
0.99 |
27.7 |
1.09 |
687 |
462 |
848 |
570 |
25D3 |
25W3 |
291 |
11.5 |
375 |
350 |
25.3 |
1.00 |
27.9 |
1.10 |
756 |
508 |
930 |
625 |
25D3 |
25W3 |
293 |
11.5 |
415 |
400 |
29.7 |
1.17 |
32.3 |
1.27 |
928 |
624 |
1116 |
750 |
30D4 |
30W4 |
339 |
13.4 |
450 |
500 |
30.3 |
1.19 |
33.0 |
1.30 |
1074 |
722 |
1281 |
861 |
30D4 |
30W4 |
346 |
13.6 |
515 |
600 |
35.1 |
1.38 |
37.6 |
1.48 |
1326 |
891 |
1548 |
1040 |
35D5 |
35W5 |
395 |
15.5 |
585 |
750 |
35.7 |
1.40 |
38.3 |
1.51 |
1561 |
1049 |
1802 |
1211 |
35D5 |
35W5 |
402 |
15.8 |
670 |
1000 |
40.3 |
1.59 |
43.5 |
1.71 |
2025 |
1361 |
2358 |
1584 |
40D5 |
40W5 |
457 |
18.0 |
800 |
|
Related documents
Selling information
1 Conductor - Black
Aluminum Conductors
**Compact aluminum ACM conductors are aluminum alloy #8030.
†C.E. Code Rule 12-712(3)