CIC Tray Cable (TC) ISOS 300V
CIC Tray Cable (TC) ISOS 300V
300V TC Rated Tray Cable Individual and Overall Aluminum Mylar Shielded Tinned Copper Pairs or Triads with Tinned Copper Drain Wires with a PVC Outer Jacket
Read more12PR 300V 16 AWG ISOS CIC TC
Nexans ref. 3XNAISOS16-12PR-PV4
- Packaging: m (1000m)
- Approximate weight: 634.56 kg/km
- Cable Diameter: 22.31 mm
- Cable Outer Diameter: 0.88 inches
- Conductor size (AWG): 16 AWG
- Number of pairs: 12
- Number of triples: 0
- Weight: 426.406 lb/Mft
- Maximum Pulling Tension: 224.73 kg
- Maximum Pulling Tension: 495.45 pounds
- Minimum Bend Radius - Install: 20.08 cm
- Minimum Bending Radius - Install: 7.91 inches
12PR 300V 18 AWG ISOS CIC TC
Nexans ref. 3XNAISOS18-12PR-PV4
- Packaging: m (1000m)
- Approximate weight: 442.05 kg/km
- Cable Diameter: 18.87 mm
- Cable Outer Diameter: 0.74 inches
- Conductor size (AWG): 18 AWG
- Number of pairs: 12
- Number of triples: 0
- Weight: 297.04 lb/Mft
- Maximum Pulling Tension: 140.85 kg
- Maximum Pulling Tension: 310.52 pounds
- Minimum Bend Radius - Install: 16.98 cm
- Minimum Bending Radius - Install: 6.69 inches
1PR 300V 16 AWG ISOS CIC TC
Nexans ref. 3XNAOS16-1PR-PV4
- Packaging: m (1000m)
- Approximate weight: 65.34 kg/km
- Cable Diameter: 6.81 mm
- Cable Outer Diameter: 0.27 inches
- Conductor size (AWG): 16 AWG
- Number of pairs: 1
- Number of triples: 0
- Weight: 43.904 lb/Mft
- Maximum Pulling Tension: 18.73 kg
- Maximum Pulling Tension: 41.29 pounds
- Minimum Bend Radius - Install: 6.13 cm
- Minimum Bending Radius - Install: 2.41 inches
1PR 300V 18 AWG OS CIC TC
Nexans ref. 3XNAOS18-1PR-PV4
- Packaging: m (1000m)
- Approximate weight: 52.04 kg/km
- Cable Diameter: 6.2 mm
- Cable Outer Diameter: 0.24 inches
- Conductor size (AWG): 18 AWG
- Number of pairs: 1
- Number of triples: 0
- Weight: 34.969 lb/Mft
- Maximum Pulling Tension: 11.74 kg
- Maximum Pulling Tension: 25.88 pounds
- Minimum Bend Radius - Install: 5.58 cm
- Minimum Bending Radius - Install: 2.2 inches
1TR 300V 16 AWG ISOS CIC TC
Nexans ref. 3XNAOS16-1TR-PV4
- Packaging: m (1000m)
- Approximate weight: 82.22 kg/km
- Cable Diameter: 7.15 mm
- Cable Outer Diameter: 0.28 inches
- Conductor size (AWG): 16 AWG
- Number of pairs: 0
- Number of triples: 1
- Weight: 55.253 lb/Mft
- Maximum Pulling Tension: 28.09 kg
- Maximum Pulling Tension: 61.93 pounds
- Minimum Bend Radius - Install: 6.43 cm
- Minimum Bending Radius - Install: 2.53 inches
1TR 300V 18 AWG ISOS CIC TC
Nexans ref. 3XNAOS18-1TR-PV4
- Packaging: m (1000m)
- Approximate weight: 63.66 kg/km
- Cable Diameter: 6.49 mm
- Cable Outer Diameter: 0.26 inches
- Conductor size (AWG): 18 AWG
- Number of pairs: 0
- Number of triples: 1
- Weight: 42.777 lb/Mft
- Maximum Pulling Tension: 17.61 kg
- Maximum Pulling Tension: 38.81 pounds
- Minimum Bend Radius - Install: 5.84 cm
- Minimum Bending Radius - Install: 2.3 inches
2PR 300V 16 AWG ISOS CIC TC
Nexans ref. 3XNAISOS16-2PR-PV4
- Packaging: m (1000m)
- Approximate weight: 134.27 kg/km
- Cable Diameter: 11.52 mm
- Cable Outer Diameter: 0.45 inches
- Conductor size (AWG): 16 AWG
- Number of pairs: 2
- Number of triples: 0
- Weight: 90.223 lb/Mft
- Maximum Pulling Tension: 37.45 kg
- Maximum Pulling Tension: 82.58 pounds
- Minimum Bend Radius - Install: 10.37 cm
- Minimum Bending Radius - Install: 4.08 inches
2PR 300V 18 AWG ISOS CIC TC
Nexans ref. 3XNAISOS18-2PR-PV4
- Packaging: m (1000m)
- Approximate weight: 107.18 kg/km
- Cable Diameter: 10.3 mm
- Cable Outer Diameter: 0.41 inches
- Conductor size (AWG): 18 AWG
- Number of pairs: 2
- Number of triples: 0
- Weight: 72.023 lb/Mft
- Maximum Pulling Tension: 23.48 kg
- Maximum Pulling Tension: 51.75 pounds
- Minimum Bend Radius - Install: 9.27 cm
- Minimum Bending Radius - Install: 3.65 inches
2TR 300V 16 AWG ISOS CIC TC
Nexans ref. 3XNAISOS16-2TR-PV4
- Packaging: m (1000m)
- Approximate weight: 171.38 kg/km
- Cable Diameter: 12.24 mm
- Cable Outer Diameter: 0.48 inches
- Conductor size (AWG): 16 AWG
- Number of pairs: 0
- Number of triples: 2
- Weight: 115.164 lb/Mft
- Maximum Pulling Tension: 56.18 kg
- Maximum Pulling Tension: 123.86 pounds
- Minimum Bend Radius - Install: 11.02 cm
- Minimum Bending Radius - Install: 4.34 inches
2TR 300V 18 AWG ISOS CIC TC
Nexans ref. 3XNAISOS18-2TR-PV4
- Packaging: m (1000m)
- Approximate weight: 131.84 kg/km
- Cable Diameter: 10.88 mm
- Cable Outer Diameter: 0.43 inches
- Conductor size (AWG): 18 AWG
- Number of pairs: 0
- Number of triples: 2
- Weight: 88.595 lb/Mft
- Maximum Pulling Tension: 35.21 kg
- Maximum Pulling Tension: 77.63 pounds
- Minimum Bend Radius - Install: 9.79 cm
- Minimum Bending Radius - Install: 3.85 inches
3PR 300V 16 AWG ISOS CIC TC
Nexans ref. 3XNAISOS16-3PR-PV4
- Packaging: m (1000m)
- Approximate weight: 176.41 kg/km
- Cable Diameter: 12.25 mm
- Cable Outer Diameter: 0.48 inches
- Conductor size (AWG): 16 AWG
- Number of pairs: 3
- Number of triples: 0
- Weight: 118.539 lb/Mft
- Maximum Pulling Tension: 56.18 kg
- Maximum Pulling Tension: 123.86 pounds
- Minimum Bend Radius - Install: 11.03 cm
- Minimum Bending Radius - Install: 4.34 inches
3PR 300V 18 AWG ISOS CIC TC
Nexans ref. 3XNAISOS18-3PR-PV4
- Packaging: m (1000m)
- Approximate weight: 136.87 kg/km
- Cable Diameter: 10.89 mm
- Cable Outer Diameter: 0.43 inches
- Conductor size (AWG): 18 AWG
- Number of pairs: 3
- Number of triples: 0
- Weight: 91.972 lb/Mft
- Maximum Pulling Tension: 35.21 kg
- Maximum Pulling Tension: 77.63 pounds
- Minimum Bend Radius - Install: 9.8 cm
- Minimum Bending Radius - Install: 3.86 inches
4PR 300V 16 AWG ISOS CIC TC
Nexans ref. 3XNAISOS16-4PR-PV4
- Packaging: m (1000m)
- Approximate weight: 243.33 kg/km
- Cable Diameter: 14.19 mm
- Cable Outer Diameter: 0.56 inches
- Conductor size (AWG): 16 AWG
- Number of pairs: 4
- Number of triples: 0
- Weight: 163.508 lb/Mft
- Maximum Pulling Tension: 74.91 kg
- Maximum Pulling Tension: 165.15 pounds
- Minimum Bend Radius - Install: 12.77 cm
- Minimum Bending Radius - Install: 5.03 inches
4PR 300V 18 AWG ISOS CIC TC
Nexans ref. 3XNAISOS18-4PR-PV4
- Packaging: m (1000m)
- Approximate weight: 168.22 kg/km
- Cable Diameter: 11.91 mm
- Cable Outer Diameter: 0.47 inches
- Conductor size (AWG): 18 AWG
- Number of pairs: 4
- Number of triples: 0
- Weight: 113.038 lb/Mft
- Maximum Pulling Tension: 46.95 kg
- Maximum Pulling Tension: 103.51 pounds
- Minimum Bend Radius - Install: 10.72 cm
- Minimum Bending Radius - Install: 4.22 inches
4TR 300V 16 AWG ISOS CIC TC
Nexans ref. 3XNAISOS16-4TR-PV4
- Packaging: m (1000m)
- Approximate weight: 321.73 kg/km
- Cable Diameter: 16.4 mm
- Cable Outer Diameter: 0.65 inches
- Conductor size (AWG): 16 AWG
- Number of pairs: 0
- Number of triples: 4
- Weight: 216.189 lb/Mft
- Maximum Pulling Tension: 112.37 kg
- Maximum Pulling Tension: 247.73 pounds
- Minimum Bend Radius - Install: 14.76 cm
- Minimum Bending Radius - Install: 5.81 inches
4TR 300V 18 AWG ISOS CIC TC
Nexans ref. 3XNAISOS18-4TR-PV4
- Packaging: m (1000m)
- Approximate weight: 246.82 kg/km
- Cable Diameter: 14.63 mm
- Cable Outer Diameter: 0.58 inches
- Conductor size (AWG): 18 AWG
- Number of pairs: 0
- Number of triples: 4
- Weight: 165.853 lb/Mft
- Maximum Pulling Tension: 70.42 kg
- Maximum Pulling Tension: 155.26 pounds
- Minimum Bend Radius - Install: 13.17 cm
- Minimum Bending Radius - Install: 5.18 inches
6PR 300V 16 AWG ISOS CIC TC
Nexans ref. 3XNAISOS16-6PR-PV4
- Packaging: m (1000m)
- Approximate weight: 328.95 kg/km
- Cable Diameter: 16.05 mm
- Cable Outer Diameter: 0.63 inches
- Conductor size (AWG): 16 AWG
- Number of pairs: 6
- Number of triples: 0
- Weight: 221.042 lb/Mft
- Maximum Pulling Tension: 112.37 kg
- Maximum Pulling Tension: 247.73 pounds
- Minimum Bend Radius - Install: 14.44 cm
- Minimum Bending Radius - Install: 5.69 inches
6PR 300V 18 AWG ISOS CIC TC
Nexans ref. 3XNAISOS18-6PR-PV4
- Packaging: m (1000m)
- Approximate weight: 254.42 kg/km
- Cable Diameter: 14.33 mm
- Cable Outer Diameter: 0.56 inches
- Conductor size (AWG): 18 AWG
- Number of pairs: 6
- Number of triples: 0
- Weight: 170.962 lb/Mft
- Maximum Pulling Tension: 70.42 kg
- Maximum Pulling Tension: 155.26 pounds
- Minimum Bend Radius - Install: 12.89 cm
- Minimum Bending Radius - Install: 5.08 inches
6TR 300V 16 AWG ISOS CIC TC
Nexans ref. 3XNAISOS16-6TR-PV4
- Packaging: m (1000m)
- Approximate weight: 446.18 kg/km
- Cable Diameter: 19.32 mm
- Cable Outer Diameter: 0.76 inches
- Conductor size (AWG): 16 AWG
- Number of pairs: 0
- Number of triples: 6
- Weight: 299.822 lb/Mft
- Maximum Pulling Tension: 168.55 kg
- Maximum Pulling Tension: 371.59 pounds
- Minimum Bend Radius - Install: 17.39 cm
- Minimum Bending Radius - Install: 6.85 inches
6TR 300V 18 AWG ISOS CIC TC
Nexans ref. 3XNAISOS18-6TR-PV4
- Packaging: m (1000m)
- Approximate weight: 337.56 kg/km
- Cable Diameter: 17.16 mm
- Cable Outer Diameter: 0.68 inches
- Conductor size (AWG): 18 AWG
- Number of pairs: 0
- Number of triples: 6
- Weight: 226.827 lb/Mft
- Maximum Pulling Tension: 105.64 kg
- Maximum Pulling Tension: 232.89 pounds
- Minimum Bend Radius - Install: 15.44 cm
- Minimum Bending Radius - Install: 6.08 inches
8PR 300V 16 AWG ISOS CIC TC
Nexans ref. 3XNAISOS16-8PR-PV4
- Packaging: m (1000m)
- Approximate weight: 416.96 kg/km
- Cable Diameter: 18.22 mm
- Cable Outer Diameter: 0.72 inches
- Conductor size (AWG): 16 AWG
- Number of pairs: 8
- Number of triples: 0
- Weight: 280.187 lb/Mft
- Maximum Pulling Tension: 149.82 kg
- Maximum Pulling Tension: 330.3 pounds
- Minimum Bend Radius - Install: 16.4 cm
- Minimum Bending Radius - Install: 6.46 inches
8PR 300V 18 AWG ISOS CIC TC
Nexans ref. 3XNAISOS18-8PR-PV4
- Packaging: m (1000m)
- Approximate weight: 319.73 kg/km
- Cable Diameter: 16.21 mm
- Cable Outer Diameter: 0.64 inches
- Conductor size (AWG): 18 AWG
- Number of pairs: 8
- Number of triples: 0
- Weight: 214.847 lb/Mft
- Maximum Pulling Tension: 93.9 kg
- Maximum Pulling Tension: 207.01 pounds
- Minimum Bend Radius - Install: 14.59 cm
- Minimum Bending Radius - Install: 5.74 inches
8TR 300V 16 AWG ISOS CIC TC
Nexans ref. 3XNAISOS16-8TR-PV4
- Packaging: m (1000m)
- Approximate weight: 619.66 kg/km
- Cable Diameter: 22.81 mm
- Cable Outer Diameter: 0.9 inches
- Conductor size (AWG): 16 AWG
- Number of pairs: 0
- Number of triples: 8
- Weight: 416.394 lb/Mft
- Maximum Pulling Tension: 224.73 kg
- Maximum Pulling Tension: 495.45 pounds
- Minimum Bend Radius - Install: 20.53 cm
- Minimum Bending Radius - Install: 8.08 inches
8TR 300V 18 AWG ISOS CIC TC
Nexans ref. 3XNAISOS18-8TR-PV4
- Packaging: m (1000m)
- Approximate weight: 425.43 kg/km
- Cable Diameter: 19.3 mm
- Cable Outer Diameter: 0.76 inches
- Conductor size (AWG): 18 AWG
- Number of pairs: 0
- Number of triples: 8
- Weight: 285.877 lb/Mft
- Maximum Pulling Tension: 140.85 kg
- Maximum Pulling Tension: 310.52 pounds
- Minimum Bend Radius - Install: 17.37 cm
- Minimum Bending Radius - Install: 6.84 inches
Description
Description
Standards
-
ProductCSA C22.2 N° 230; CSA C22.2 N° 239; CSA C22.2 N° 2556; CSA C22.2 N° 38
-
TestIEEE 1202; IEEE 383; UL 1685
Applications
Control and Instrumentation Cable manufactured to strict Canadian Standards Association (CSA) requirements, it is a highly rugged, multi-conductor cable designed to transmit analog or digital signals in heavy industrial, harsh, and hazardous environments. Used for connecting PLC (Programmable Logic Controller) systems to field instruments, sensors, valves, and actuators.
- For use in raceways, ventilated, non-ventilated and ladder-type cable trays.
- For dry, damp or wet locations, in ceiling air-handling plenums, direct burial, exposed and concealed wiring.
- For use in Hazardous locations: Zone 0 (intrinsically safe cables only), Zone 2, Zone 22 (per Section 18).
Specifications and Compliances
- CSA C22.2 No. 239, Control and instrumentation cables (Type CIC)
- CSA C22.2 No. 38, Thermoset-insulated wires and cables (Type RW90)
- CSA C22.2 No. 230, Tray Cables (TC)
- CSA C22.2 No. 2556 FT4, UL 1685 Vertical-Tray Flame Test
- IEEE 383 & 1202, ICEA T-30-520 (70,000 BTU/hr) Vertical Flame Test rated
- -40°C Cold Bend and -40°C Cold Impact
- Sunlight Resistant, SUN RES. Low Acid Gas, AG14.
Highlights
- Nexans CIC Tray Cable (TC) are: Available from stock
- Versatile & Flexible
- Resistant to Mechanical Abuse and Corrosion
- Compact and Reliable
- 90°C to -40°C
- Low Acid Gas (AG14) • Sunlight resistant
- LEAD FREE & RoHS compliant
- Marked HL to CSA C22.2 No. 174
- FT4 flame spread rating
- HAL-FREE FT4-ST1 available upon request
Marking and Identification
- Black and White Pairs
- Black, White and Red Triads
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania