CIC Tray Cable (TC) ISOS 600V

Products

12PR 600V 16 AWG ISOS CIC TC

Nexans ref. 6XNAISOS16-12PR-PV4

  • Packaging: m (1000m)
  • Approximate weight: 797.05 kg/km
  • Cable Diameter: 28.38 mm
  • Cable Outer Diameter: 1.12 inches
  • Conductor size (AWG): 16 AWG
  • Number of pairs: 12
  • Number of triples: 0
  • Weight: 535.589 lb/Mft
  • Maximum Pulling Tension: 495.45 kg
  • Maximum Pulling Tension: 224.73 pounds
  • Minimum Bend Radius - Install: 25.54 cm
  • Minimum Bending Radius - Install: 10.05 inches

 

12PR 600V 18 AWG ISOS CIC TC

Nexans ref. 6XNAOS18-1TR-PV4

  • Packaging: m (1000m)
  • Approximate weight: 638.03 kg/km
  • Cable Diameter: 25.95 mm
  • Cable Outer Diameter: 1.02 inches
  • Conductor size (AWG): 18 AWG
  • Number of pairs: 12
  • Number of triples: 0
  • Weight: 428.734 lb/Mft
  • Maximum Pulling Tension: 310.52 kg
  • Maximum Pulling Tension: 140.85 pounds
  • Minimum Bend Radius - Install: 23.36 cm
  • Minimum Bending Radius - Install: 9.2 inches

 

1PR 600V 16 AWG OS CIC TC

Nexans ref. 6XNAISOS16-2PR-PV4

  • Packaging: m (1000m)
  • Approximate weight: 81.81 kg/km
  • Cable Diameter: 8.34 mm
  • Cable Outer Diameter: 0.33 inches
  • Conductor size (AWG): 16 AWG
  • Number of pairs: 1
  • Number of triples: 0
  • Weight: 54.977 lb/Mft
  • Maximum Pulling Tension: 41.29 kg
  • Maximum Pulling Tension: 18.73 pounds
  • Minimum Bend Radius - Install: 7.5 cm
  • Minimum Bending Radius - Install: 2.95 inches

 

1PR 600V AWG OS CIC TC

Nexans ref. 6XNAISOS18-3PR-PV4

  • Packaging: m (1000m)
  • Approximate weight: 67.54 kg/km
  • Cable Diameter: 7.73 mm
  • Cable Outer Diameter: 0.3 inches
  • Conductor size (AWG): 18 AWG
  • Number of pairs: 1
  • Number of triples: 0
  • Weight: 45.385 lb/Mft
  • Maximum Pulling Tension: 25.88 kg
  • Maximum Pulling Tension: 11.74 pounds
  • Minimum Bend Radius - Install: 6.95 cm
  • Minimum Bending Radius - Install: 2.74 inches

 

1TR 600V 16 AWG OS CIC TC

Nexans ref. 6XNAOS16-1TR-PV4

  • Packaging: m (1000m)
  • Approximate weight: 103.49 kg/km
  • Cable Diameter: 8.78 mm
  • Cable Outer Diameter: 0.35 inches
  • Conductor size (AWG): 16 AWG
  • Number of pairs: 0
  • Number of triples: 1
  • Weight: 69.543 lb/Mft
  • Maximum Pulling Tension: 61.93 kg
  • Maximum Pulling Tension: 28.09 pounds
  • Minimum Bend Radius - Install: 7.91 cm
  • Minimum Bending Radius - Install: 3.11 inches

 

1TR 600V 18 AWG OS CIC TC

Nexans ref. 6XNAISOS18-2TR-PV4

  • Packaging: m (1000m)
  • Approximate weight: 83.46 kg/km
  • Cable Diameter: 8.13 mm
  • Cable Outer Diameter: 0.32 inches
  • Conductor size (AWG): 18 AWG
  • Number of pairs: 0
  • Number of triples: 1
  • Weight: 56.081 lb/Mft
  • Maximum Pulling Tension: 38.81 kg
  • Maximum Pulling Tension: 17.61 pounds
  • Minimum Bend Radius - Install: 7.32 cm
  • Minimum Bending Radius - Install: 2.88 inches

 

2PR 600V 16 AWG ISOS CIC TC

Nexans ref. 6XNAOS18-1PR-PV4

  • Packaging: m (1000m)
  • Approximate weight: 196.37 kg/km
  • Cable Diameter: 15.38 mm
  • Cable Outer Diameter: 0.61 inches
  • Conductor size (AWG): 18 AWG
  • Number of pairs: 2
  • Number of triples: 0
  • Weight: 131.956 lb/Mft
  • Maximum Pulling Tension: 82.58 kg
  • Maximum Pulling Tension: 37.45 pounds
  • Minimum Bend Radius - Install: 13.84 cm
  • Minimum Bending Radius - Install: 5.45 inches

 

2PR 600V 18 AWG ISOS CIC TC

Nexans ref. 6XNAISOS18-2PR-PV4

  • Packaging: m (1000m)
  • Approximate weight: 165.06 kg/km
  • Cable Diameter: 14.16 mm
  • Cable Outer Diameter: 0.56 inches
  • Conductor size (AWG): 18 AWG
  • Number of pairs: 2
  • Number of triples: 0
  • Weight: 110.916 lb/Mft
  • Maximum Pulling Tension: 51.75 kg
  • Maximum Pulling Tension: 23.48 pounds
  • Minimum Bend Radius - Install: 12.75 cm
  • Minimum Bending Radius - Install: 5.02 inches

 

2TR 600V 16 AWG ISOS CIC TC

Nexans ref. 6XNAISOS16-2TR-PV4

  • Packaging: m (1000m)
  • Approximate weight: 244.03 kg/km
  • Cable Diameter: 16.28 mm
  • Cable Outer Diameter: 0.64 inches
  • Conductor size (AWG): 16 AWG
  • Number of pairs: 0
  • Number of triples: 2
  • Weight: 163.984 lb/Mft
  • Maximum Pulling Tension: 123.86 kg
  • Maximum Pulling Tension: 56.18 pounds
  • Minimum Bend Radius - Install: 14.65 cm
  • Minimum Bending Radius - Install: 5.77 inches

 

2TR 600V 18 AWG ISOS CIC TC

Nexans ref. 6XNAISOS18-4TR-PV4

  • Packaging: m (1000m)
  • Approximate weight: 200.35 kg/km
  • Cable Diameter: 14.97 mm
  • Cable Outer Diameter: 0.59 inches
  • Conductor size (AWG): 18 AWG
  • Number of pairs: 0
  • Number of triples: 2
  • Weight: 134.629 lb/Mft
  • Maximum Pulling Tension: 77.63 kg
  • Maximum Pulling Tension: 35.21 pounds
  • Minimum Bend Radius - Install: 13.47 cm
  • Minimum Bending Radius - Install: 5.3 inches

 

3PR 600V 16 AWG ISOS CIC TC

Nexans ref. 6XNAISOS16-3PR-PV4

  • Packaging: m (1000m)
  • Approximate weight: 249.07 kg/km
  • Cable Diameter: 16.29 mm
  • Cable Outer Diameter: 0.64 inches
  • Conductor size (AWG): 16 AWG
  • Number of pairs: 3
  • Number of triples: 0
  • Weight: 167.369 lb/Mft
  • Maximum Pulling Tension: 123.86 kg
  • Maximum Pulling Tension: 56.18 pounds
  • Minimum Bend Radius - Install: 14.66 cm
  • Minimum Bending Radius - Install: 5.77 inches

 

3PR 600V 18 AWG ISOS CIC TC

Nexans ref. 6XNAISOS18-4PR-PV4

  • Packaging: m (1000m)
  • Approximate weight: 205.39 kg/km
  • Cable Diameter: 14.98 mm
  • Cable Outer Diameter: 0.59 inches
  • Conductor size (AWG): 18 AWG
  • Number of pairs: 3
  • Number of triples: 0
  • Weight: 138.016 lb/Mft
  • Maximum Pulling Tension: 77.63 kg
  • Maximum Pulling Tension: 35.21 pounds
  • Minimum Bend Radius - Install: 13.48 cm
  • Minimum Bending Radius - Install: 5.31 inches

 

4PR 600V 16 AWG ISOS CIC TC

Nexans ref. 6XNAISOS16-4PR-PV4

  • Packaging: m (1000m)
  • Approximate weight: 305.29 kg/km
  • Cable Diameter: 17.86 mm
  • Cable Outer Diameter: 0.7 inches
  • Conductor size (AWG): 16 AWG
  • Number of pairs: 4
  • Number of triples: 0
  • Weight: 205.144 lb/Mft
  • Maximum Pulling Tension: 165.15 kg
  • Maximum Pulling Tension: 74.91 pounds
  • Minimum Bend Radius - Install: 16.08 cm
  • Minimum Bending Radius - Install: 6.33 inches

 

4PR 600V 18 AWG ISOS CIC TC

Nexans ref. 6XNAISOS18-6PR-PV4

  • Packaging: m (1000m)
  • Approximate weight: 249.16 kg/km
  • Cable Diameter: 16.39 mm
  • Cable Outer Diameter: 0.65 inches
  • Conductor size (AWG): 18 AWG
  • Number of pairs: 4
  • Number of triples: 0
  • Weight: 167.429 lb/Mft
  • Maximum Pulling Tension: 103.51 kg
  • Maximum Pulling Tension: 46.95 pounds
  • Minimum Bend Radius - Install: 14.75 cm
  • Minimum Bending Radius - Install: 5.81 inches

 

4TR 600V 16 AWG ISOS CIC TC

Nexans ref. 6XNAISOS16-4TR-PV4

  • Packaging: m (1000m)
  • Approximate weight: 406.42 kg/km
  • Cable Diameter: 20.83 mm
  • Cable Outer Diameter: 0.82 inches
  • Conductor size (AWG): 16 AWG
  • Number of pairs: 0
  • Number of triples: 4
  • Weight: 273.101 lb/Mft
  • Maximum Pulling Tension: 247.73 kg
  • Maximum Pulling Tension: 112.37 pounds
  • Minimum Bend Radius - Install: 18.74 cm
  • Minimum Bending Radius - Install: 7.38 inches

 

4TR 600V 18 AWG ISOS CIC TC

Nexans ref. 6XNAISOS18-6TR-PV4

  • Packaging: m (1000m)
  • Approximate weight: 325.53 kg/km
  • Cable Diameter: 19.06 mm
  • Cable Outer Diameter: 0.75 inches
  • Conductor size (AWG): 18 AWG
  • Number of pairs: 0
  • Number of triples: 4
  • Weight: 218.745 lb/Mft
  • Maximum Pulling Tension: 155.26 kg
  • Maximum Pulling Tension: 70.42 pounds
  • Minimum Bend Radius - Install: 17.15 cm
  • Minimum Bending Radius - Install: 6.75 inches

 

6PR 600V 16 AWG ISOS CIC TC

Nexans ref. 6XNAISOS16-6PR-PV4

  • Packaging: m (1000m)
  • Approximate weight: 412.68 kg/km
  • Cable Diameter: 20.34 mm
  • Cable Outer Diameter: 0.8 inches
  • Conductor size (AWG): 16 AWG
  • Number of pairs: 6
  • Number of triples: 0
  • Weight: 277.31 lb/Mft
  • Maximum Pulling Tension: 247.73 kg
  • Maximum Pulling Tension: 112.37 pounds
  • Minimum Bend Radius - Install: 18.31 cm
  • Minimum Bending Radius - Install: 7.21 inches

 

6PR 600V 18 AWG ISOS CIC TC

Nexans ref. 6XNAISOS18-8PR-PV4

  • Packaging: m (1000m)
  • Approximate weight: 332.18 kg/km
  • Cable Diameter: 18.62 mm
  • Cable Outer Diameter: 0.73 inches
  • Conductor size (AWG): 18 AWG
  • Number of pairs: 6
  • Number of triples: 0
  • Weight: 223.212 lb/Mft
  • Maximum Pulling Tension: 155.26 kg
  • Maximum Pulling Tension: 70.42 pounds
  • Minimum Bend Radius - Install: 16.76 cm
  • Minimum Bending Radius - Install: 6.6 inches

 

6TR 600V 16 AWG ISOS CIC TC

Nexans ref. 6XNAISOS16-6TR-PV4

  • Packaging: m (1000m)
  • Approximate weight: 623.09 kg/km
  • Cable Diameter: 25.74 mm
  • Cable Outer Diameter: 1.01 inches
  • Conductor size (AWG): 16 AWG
  • Number of pairs: 0
  • Number of triples: 6
  • Weight: 418.694 lb/Mft
  • Maximum Pulling Tension: 371.59 kg
  • Maximum Pulling Tension: 168.55 pounds
  • Minimum Bend Radius - Install: 23.17 cm
  • Minimum Bending Radius - Install: 9.12 inches

 

6TR 600V 18 AWG ISOS CIC TC

Nexans ref. 6XNAISOS18-8TR-PV4

  • Packaging: m (1000m)
  • Approximate weight: 500.41 kg/km
  • Cable Diameter: 23.58 mm
  • Cable Outer Diameter: 0.93 inches
  • Conductor size (AWG): 18 AWG
  • Number of pairs: 0
  • Number of triples: 6
  • Weight: 336.261 lb/Mft
  • Maximum Pulling Tension: 232.89 kg
  • Maximum Pulling Tension: 105.64 pounds
  • Minimum Bend Radius - Install: 21.22 cm
  • Minimum Bending Radius - Install: 8.36 inches

 

8PR 600V 16 AWG ISOS CIC TC

Nexans ref. 6XNAISOS16-8PR-PV4

  • Packaging: m (1000m)
  • Approximate weight: 579.01 kg/km
  • Cable Diameter: 24.26 mm
  • Cable Outer Diameter: 0.95 inches
  • Conductor size (AWG): 16 AWG
  • Number of pairs: 8
  • Number of triples: 0
  • Weight: 389.079 lb/Mft
  • Maximum Pulling Tension: 330.3 kg
  • Maximum Pulling Tension: 149.82 pounds
  • Minimum Bend Radius - Install: 21.84 cm
  • Minimum Bending Radius - Install: 8.6 inches

 

8PR 600V 18 AWG ISOS CIC TC

Nexans ref. 6XNAISOS18-12PR-PV4

  • Packaging: m (1000m)
  • Approximate weight: 469.08 kg/km
  • Cable Diameter: 22.25 mm
  • Cable Outer Diameter: 0.88 inches
  • Conductor size (AWG): 18 AWG
  • Number of pairs: 8
  • Number of triples: 0
  • Weight: 315.209 lb/Mft
  • Maximum Pulling Tension: 207.01 kg
  • Maximum Pulling Tension: 93.9 pounds
  • Minimum Bend Radius - Install: 20.03 cm
  • Minimum Bending Radius - Install: 7.88 inches

 

8TR 600V 16 AWG ISOS CIC TC

Nexans ref. 6XNAISOS16-8TR-PV4

  • Packaging: m (1000m)
  • Approximate weight: 783.9 kg/km
  • Cable Diameter: 29.06 mm
  • Cable Outer Diameter: 1.14 inches
  • Conductor size (AWG): 16 AWG
  • Number of pairs: 0
  • Number of triples: 8
  • Weight: 526.757 lb/Mft
  • Maximum Pulling Tension: 495.45 kg
  • Maximum Pulling Tension: 224.73 pounds
  • Minimum Bend Radius - Install: 26.15 cm
  • Minimum Bending Radius - Install: 10.3 inches

 

8TR 600V 18 AWG ISOS CIC TC

Nexans ref. 6XNAOS16-1PR-PV4

  • Packaging: m (1000m)
  • Approximate weight: 624.18 kg/km
  • Cable Diameter: 26.56 mm
  • Cable Outer Diameter: 1.05 inches
  • Conductor size (AWG): 16 AWG
  • Number of pairs: 0
  • Number of triples: 8
  • Weight: 419.43 lb/Mft
  • Maximum Pulling Tension: 310.52 kg
  • Maximum Pulling Tension: 140.85 pounds
  • Minimum Bend Radius - Install: 23.9 cm
  • Minimum Bending Radius - Install: 9.41 inches

 

Description

Description

Standards

  • Product
    CSA C22.2 N° 230; CSA C22.2 N° 239; CSA C22.2 N° 2556; CSA C22.2 N° 38
  • Test
    IEEE 1202; IEEE 383; UL 1685

Applications

Control and Instrumentation Cable manufactured to strict Canadian Standards Association (CSA) requirements, it is a highly rugged, multi-conductor cable designed to transmit analog or digital signals in heavy industrial, harsh, and hazardous environments. Used for connecting PLC (Programmable Logic Controller) systems to field instruments, sensors, valves, and actuators.

  • For use in raceways, ventilated, non-ventilated and ladder-type cable trays.
  • For dry, damp or wet locations, in ceiling air-handling plenums, direct burial, exposed and concealed wiring.
  • For use in Hazardous locations: Zone 0 (intrinsically safe cables only), Zone 2, Zone 22 (per Section 18).

Specifications and Compliances

  •  CSA C22.2 No. 239, Control and instrumentation cables (Type CIC)
  •  CSA C22.2 No. 38, Thermoset-insulated wires and cables (Type RW90)
  •  CSA C22.2 No. 230, Tray Cables (TC)
  •  CSA C22.2 No. 2556 FT4, UL 1685 Vertical-Tray Flame Test
  •  IEEE 383 & 1202, ICEA T-30-520 (70,000 BTU/hr) Vertical Flame Test rated
  •  -40°C Cold Bend and -40°C Cold Impact
  •  Sunlight Resistant, SUN RES. Low Acid Gas, AG14.

Highlights

  • Nexans CIC Tray Cable (TC) are: Available from stock
  • Versatile & Flexible
  • Resistant to Mechanical Abuse and Corrosion
  • Compact and Reliable
  • 90°C to -40°C
  • Low Acid Gas (AG14) • Sunlight resistant
  • LEAD FREE & RoHS compliant
  • Marked HL to CSA C22.2 No. 174
  • FT4 flame spread rating
  • HAL-FREE FT4-ST1 available upon request

Marking and Identification

  1. Black and White Pairs 
  2. Black, White and Red Triads

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor Material
Tinned copper
Insulation
Cross-linked polyethylene
Jacket material
PVC
Shielding
Aluminum Mylar

Dimensional characteristics

Dimensional characteristics

Average insulation thickness
0.8 mm
Average insulation thickness
.03 inches

Electrical characteristics

Electrical characteristics

Maximum operating voltage
600 V

Usage characteristics

Usage characteristics

Maximum operating temperature
90 °C
Minimum installation temperature
-40 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close