TECK90 1 kV

Products

1C350(36) TECK90 1KV

Nexans ref. 12000506 - Country ref. 550384

  • Packaging: Cut to length (m)
  • Approximate net weight: 2842.1 kg/km
  • Cable Diameter: 36.8 mm
  • Conductor diameter (mm): 15.646
  • Conductor size (AWG): 350 MCM
  • Finished Cable Diameter: 1.449 inches
  • Nominal cable weight: 1910 lb/kft
  • Number of strands: 36

 

1C500(36) TECK90 1KV

Nexans ref. 12000507 - Country ref. 550392

  • Packaging: Cut to length (m)
  • Approximate net weight: 3733.1 kg/km
  • Cable Diameter: 40.26 mm
  • Conductor diameter (mm): 18.694
  • Conductor size (AWG): 500 MCM
  • Finished Cable Diameter: 1.585 inches
  • Nominal cable weight: 2509 lb/kft
  • Number of strands: 36

 

1C750(58) TECK90 1KV

Nexans ref. 12000794 - Country ref. 606802

  • Packaging: Cut to length (m)
  • Approximate net weight: 5225.4 kg/km
  • Cable Diameter: 44.9 mm
  • Conductor diameter (mm): 23.06
  • Conductor size (AWG): 750 MCM
  • Finished Cable Diameter: 1.768 inches
  • Nominal cable weight: 3511 lb/kft
  • Number of strands: 58

 

2C12(7) TECK90 1KV

Nexans ref. 12000213 - Country ref. 133280

  • Packaging: Cut to length (m)
  • Approximate net weight: 393.758 kg/km
  • Cable Diameter: 19.71 mm
  • Conductor diameter (mm): -
  • Conductor size (AWG): 12 AWG
  • Finished Cable Diameter: 0.776 inches
  • Nominal cable weight: 265 lb/kft
  • Number of strands: 7

 

2C6(7) TECK90 1KV

Nexans ref. 12000082 - Country ref. 422493

  • Packaging: Cut to length (m)
  • Approximate net weight: 840.236 kg/km
  • Cable Diameter: 26.27 mm
  • Conductor diameter (mm): -
  • Conductor size (AWG): 6 AWG
  • Finished Cable Diameter: 1.034 inches
  • Nominal cable weight: 565 lb/kft
  • Number of strands: 7

 

2C8(7) TECK90 1KV

Nexans ref. 12000304 - Country ref. 307884

  • Packaging: Cut to length (m)
  • Approximate net weight: 560 kg/km
  • Cable Diameter: 22.83 mm
  • Conductor diameter (mm): -
  • Conductor size (AWG): 8 AWG
  • Finished Cable Diameter: 0.899 inches
  • Nominal cable weight: 376 lb/kft
  • Number of strands: 7

 

3C1(18) TECK90 1KV

Nexans ref. 12000079 - Country ref. 422402

  • Packaging: Cut to length (m)
  • Approximate net weight: 2285 kg/km
  • Cable Diameter: 38.57 mm
  • Conductor diameter (mm): -
  • Conductor size (AWG): 1 AWG
  • Finished Cable Diameter: 1.519 inches
  • Nominal cable weight: 1535 lb/kft
  • Number of strands: 18

 

3C1/0(18) TECK90 1KV

Nexans ref. 12000080 - Country ref. 422410

  • Packaging: Cut to length (m)
  • Approximate net weight: 2741.711 kg/km
  • Cable Diameter: 40.71 mm
  • Conductor diameter (mm): -
  • Conductor size (AWG): 1/0 AWG
  • Finished Cable Diameter: 1.603 inches
  • Nominal cable weight: 1842 lb/kft
  • Number of strands: 18

 

3C10(7) TECK90 1KV

Nexans ref. 12000301 - Country ref. 307843

  • Packaging: Cut to length (m)
  • Approximate net weight: 582.297 kg/km
  • Cable Diameter: 22.55 mm
  • Conductor diameter (mm): -
  • Conductor size (AWG): 10 AWG
  • Finished Cable Diameter: 0.888 inches
  • Nominal cable weight: 391 lb/kft
  • Number of strands: 7

 

3C12(7) TECK90 1KV

Nexans ref. 12000302 - Country ref. 307850

  • Packaging: Cut to length (m)
  • Approximate net weight: 439.925 kg/km
  • Cable Diameter: 20.43 mm
  • Conductor diameter (mm): -
  • Conductor size (AWG): 12 AWG
  • Finished Cable Diameter: 0.804 inches
  • Nominal cable weight: 296 lb/kft
  • Number of strands: 7

 

3C2(7) TECK90 1KV

Nexans ref. 12000078 - Country ref. 422394

  • Packaging: Cut to length (m)
  • Approximate net weight: 1944.813 kg/km
  • Cable Diameter: 34.59 mm
  • Conductor diameter (mm): -
  • Conductor size (AWG): 2 AWG
  • Finished Cable Diameter: 1.362 inches
  • Nominal cable weight: 1307 lb/kft
  • Number of strands: 7

 

3C2/0(18) TECK90 1KV

Nexans ref. 12000081 - Country ref. 422428

  • Packaging: Cut to length (m)
  • Approximate net weight: 3162.723 kg/km
  • Cable Diameter: 43.37 mm
  • Conductor diameter (mm): -
  • Conductor size (AWG): 2/0 AWG
  • Finished Cable Diameter: 1.707 inches
  • Nominal cable weight: 2125 lb/kft
  • Number of strands: 18

 

3C250(36) TECK90 1KV

Nexans ref. 12000100 - Country ref. 438945

  • Packaging: Cut to length (m)
  • Approximate net weight: 5756.403 kg/km
  • Cable Diameter: 54.92 mm
  • Conductor diameter (mm): -
  • Conductor size (AWG): 250 MCM
  • Finished Cable Diameter: 2.162 inches
  • Nominal cable weight: 3868 lb/kft
  • Number of strands: 36

 

3C3(7) TECK90 1KV

Nexans ref. 12000303 - Country ref. 307876

  • Packaging: Cut to length (m)
  • Approximate net weight: 1641.155 kg/km
  • Cable Diameter: 33.01 mm
  • Conductor diameter (mm): -
  • Conductor size (AWG): 3 AWG
  • Finished Cable Diameter: 1.30 inches
  • Nominal cable weight: 1103 lb/kft
  • Number of strands: 7

 

3C3/0(18) TECK90 1KV

Nexans ref. 12000098 - Country ref. 438929

  • Packaging: Cut to length (m)
  • Approximate net weight: 3822 kg/km
  • Cable Diameter: 45.97 mm
  • Conductor diameter (mm): -
  • Conductor size (AWG): 3/0 AWG
  • Finished Cable Diameter: 1.81 inches
  • Nominal cable weight: 2568 lb/kft
  • Number of strands: 18

 

3C350(36) TECK90 1KV

Nexans ref. 12000101 - Country ref. 438960

  • Packaging: Cut to length (m)
  • Approximate net weight: 7480.509 kg/km
  • Cable Diameter: 60.21 mm
  • Conductor diameter (mm): -
  • Conductor size (AWG): 350 MCM
  • Finished Cable Diameter: 2.37 inches
  • Nominal cable weight: 5027 lb/kft
  • Number of strands: 36

 

3C4(7) TECK90 1KV

Nexans ref. 12000077 - Country ref. 422386

  • Packaging: Cut to length (m)
  • Approximate net weight: 1380 kg/km
  • Cable Diameter: 31.5 mm
  • Conductor diameter (mm): -
  • Conductor size (AWG): 4 AWG
  • Finished Cable Diameter: 1.24 inches
  • Nominal cable weight: 927 lb/kft
  • Number of strands: 7

 

3C4/0(18) TECK90 1KV

Nexans ref. 12000099 - Country ref. 438937

  • Packaging: Cut to length (m)
  • Approximate net weight: 4691.29 kg/km
  • Cable Diameter: 49.7 mm
  • Conductor diameter (mm): -
  • Conductor size (AWG): 4/0 AWG
  • Finished Cable Diameter: 1.957 inches
  • Nominal cable weight: 3152 lb/kft
  • Number of strands: 18

 

3C500(36) TECK90 1KV

Nexans ref. 12000102 - Country ref. 438986

  • Packaging: Cut to length (m)
  • Approximate net weight: 9624.4 kg/km
  • Cable Diameter: 68.2 mm
  • Conductor diameter (mm): -
  • Conductor size (AWG): 500 MCM
  • Finished Cable Diameter: 2.685 inches
  • Nominal cable weight: 6467 lb/kft
  • Number of strands: 36

 

3C6(7) TECK90 1KV x300m

Nexans ref. 12013456

  • Packaging: Reel (300m)
  • Approximate net weight: 967 kg/km
  • Cable Diameter: 27.47 mm
  • Conductor diameter (mm): -
  • Conductor size (AWG): 6 AWG
  • Finished Cable Diameter: 1.081 inches
  • Nominal cable weight: 650 lb/kft
  • Number of strands: 7

 

3C8(7) TECK90 1KV

Nexans ref. 12000075

  • Packaging: Cut to length (m)
  • Approximate net weight: 683.72 kg/km
  • Cable Diameter: 23.81 mm
  • Conductor diameter (mm): 3.4
  • Conductor size (AWG): 8 AWG
  • Finished Cable Diameter: 0.937 inches
  • Nominal cable weight: 459.44 lb/kft
  • Number of strands: 7

 

3C8(7) TECK90 1KV x300m

Nexans ref. 12013455

  • Packaging: Reel (300m)
  • Approximate net weight: 724.967 kg/km
  • Cable Diameter: 23.81 mm
  • Conductor diameter (mm): -
  • Conductor size (AWG): 8 AWG
  • Finished Cable Diameter: 0.937 inches
  • Nominal cable weight: 487 lb/kft
  • Number of strands: 7

 

4C2(7) TECK90 1KV

Nexans ref. 12000111 - Country ref. 383646

  • Packaging: Cut to length (m)
  • Approximate net weight: 2322.338 kg/km
  • Cable Diameter: 37.63 mm
  • Conductor diameter (mm): -
  • Conductor size (AWG): 2 AWG
  • Finished Cable Diameter: 1.481 inches
  • Nominal cable weight: 1561 lb/kft
  • Number of strands: 7

 

4C2/0(18) TECK90 1KV

Nexans ref. 12000104 - Country ref. 443358

  • Packaging: Cut to length (m)
  • Approximate net weight: 3943 kg/km
  • Cable Diameter: 46.95 mm
  • Conductor diameter (mm): -
  • Conductor size (AWG): 2/0 AWG
  • Finished Cable Diameter: 1.848 inches
  • Nominal cable weight: 2650 lb/kft
  • Number of strands: 18

 

4C3(7) TECK90 1KV

Nexans ref. 12000256 - Country ref. 199588

  • Packaging: Cut to length (m)
  • Approximate net weight: 2013.765 kg/km
  • Cable Diameter: 36.08 mm
  • Conductor diameter (mm): -
  • Conductor size (AWG): 3 AWG
  • Finished Cable Diameter: 1.42 inches
  • Nominal cable weight: 1353 lb/kft
  • Number of strands: 7

 

4C3/0(18) TECK90 1KV

Nexans ref. 12000452 - Country ref. 568279

  • Packaging: Cut to length (m)
  • Approximate net weight: 5051.689 kg/km
  • Cable Diameter: 50.72 mm
  • Conductor diameter (mm): -
  • Conductor size (AWG): 3/0 AWG
  • Finished Cable Diameter: 1.997 inches
  • Nominal cable weight: 3395 lb/kft
  • Number of strands: 18

 

4C350(36) TECK90 1KV

Nexans ref. 12000217 - Country ref. 137893

  • Packaging: Cut to length (m)
  • Approximate net weight: - kg/km
  • Cable Diameter: 67.7 mm
  • Conductor diameter (mm): -
  • Conductor size (AWG): 350 MCM
  • Finished Cable Diameter: 2.66 inches
  • Nominal cable weight: 9341 lb/kft
  • Number of strands: 36

 

4C4(7) TECK90 1KV

Nexans ref. 12000502 - Country ref. 529271

  • Packaging: Cut to length (m)
  • Approximate net weight: 1744.36 kg/km
  • Cable Diameter: 33.81 mm
  • Conductor diameter (mm): -
  • Conductor size (AWG): 4 AWG
  • Finished Cable Diameter: 1.331 inches
  • Nominal cable weight: 1172 lb/kft
  • Number of strands: 7

 

4C4/0(18) TECK90 1KV

Nexans ref. 12000456 - Country ref. 568709

  • Packaging: Cut to length (m)
  • Approximate net weight: 6277.938 kg/km
  • Cable Diameter: 55.56 mm
  • Conductor diameter (mm): -
  • Conductor size (AWG): 4/0 AWG
  • Finished Cable Diameter: 2.187 inches
  • Nominal cable weight: 4219 lb/kft
  • Number of strands: 18

 

4C500(36) TECK90 1KV

Nexans ref. 12000454 - Country ref. 568345

  • Packaging: Cut to length (m)
  • Approximate net weight: 13089.029 kg/km
  • Cable Diameter: 73.79 mm
  • Conductor diameter (mm): -
  • Conductor size (AWG): 500 MCM
  • Finished Cable Diameter: 2.905 inches
  • Nominal cable weight: 8795 lb/kft
  • Number of strands: 36

 

4C6(7) TECK90 1KV

Nexans ref. 12000110 - Country ref. 383620

  • Packaging: Cut to length (m)
  • Approximate net weight: 1260.651 kg/km
  • Cable Diameter: 30.52 mm
  • Conductor diameter (mm): -
  • Conductor size (AWG): 6 AWG
  • Finished Cable Diameter: 1.202 inches
  • Nominal cable weight: 847 lb/kft
  • Number of strands: 7

 

4C8(7) TECK90 1KV

Nexans ref. 12000310 - Country ref. 383612

  • Packaging: Cut to length (m)
  • Approximate net weight: 902.993 kg/km
  • Cable Diameter: 25.7 mm
  • Conductor diameter (mm): -
  • Conductor size (AWG): 8 AWG
  • Finished Cable Diameter: 1.012 inches
  • Nominal cable weight: 607 lb/kft
  • Number of strands: 7

 

Description

Description

Standards

  • National
    CSA C22.2 N° 131; CSA C22.2 N° 174

Nexans TECK90 Cables are intended for use in various primary and secondary industries, including chemical processing plants, refineries and general factory environments.

Even in the most demanding industrial and resource industry applications, Nexans TECK90 cables have proven to have a superior service and maintenance record.


TECK90 Cables utilize low acid gas, low flame spread PVC jacket compounds to ensure maximum safety to personnel and equipment in the event of fire.

Applications

TECK90 Cables, originally developed for use in Canadian mines, are flexible, resistant to mechanical abuse, corrosion resistant, compact and reliable. They are suitable for a wide range of applications, including ALL hazardous locations - Class I, Division 1 and 2; Class II, Division 1 and 2; and Class III.

Limited Smoke Zero Halogen - CSA rated ST1 per CSA 22.2 No. 2556 upon request. Meets the FT4 flame spread test.

Industries such as pulp and paper, chemical, petroleum and other primary and secondary manufacturing industries have used TECK90 Cables, particularly in areas where cables are subject to the risk of mechanical damage and chemical attack.

Commercial applications for TECK90 Cables include apartment buildings and commercial complexes.

TECK90 Cables can be relocated easily because they are rugged and flexible. They can be used in both dry and wet locations in open wiring, in ventilated, non-ventilated and ladder-type cable troughs, in ventilated flexible cableways, and for direct burial.

TECK90 Cables are also suitable for service entrance installations - above and below ground.

Highlights

Nexans TECK90 Cables are:

  • Available from stock
  • Versatile
  • Flexible
  • Resistant to Mechanical Abuse and Corrosion
  • Compact and Reliable
  • "HL" and "FT4" Rated per CSA
  • 90°C to -40°C
  • Low Acid Gas (AG14)
  • Inner and outer jackets are sunlight resistant
  • LEAD FREE
  • RoHS compliant
  • ST1 rating available upon request


Marking and Identification
The inner jackets of Nexans TECK90 cables are printed: SUN RES.

The outer jackets of Nexans TECK90 cables are printed: (mon/year) NEXANS TECK90 XLPE (-40°C) CSA LL19376 F HL FT4 AG14 SUN RES along with conductor size, number of conductors and sequential metre marking.

Marking and Identification

TECK90 1C
Conductor Identification: Black

TECK90 2C
Conductor Identification: Black, White
- 14 AWG to 2 AWG: Coloured Insulation
- 1 AWG to 500 kcmil: Coloured Stripes

TECK90 3C
Conductor Identification:
Red, Black, Blue
- 14 AWG to 2 AWG: Coloured Insulation
- 1 AWG to 500 kcmil: Coloured Stripes

TECK90 4C
Conductor Identification:
Red, Black, Blue, White
- 14 AWG to 2 AWG: Coloured Insulation
- 1 AWG to 500 kcmil: Coloured Stripes

 

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Copper
Insulation
XLPE
Jacket Colour
Black

Electrical characteristics

Electrical characteristics

Maximum operating voltage
1 kV

Usage characteristics

Usage characteristics

Maximum operating temperature
90 °C
Minimum installation temperature
-40 °C

Resources

Resources

Selling & delivery Information

Caution Notice

In case of fire, well maintained early warning smoke detectors will give an alarm long before non-metallic coverings become combustible.

However, in spite of the widespread and long-standing use of PVC in residential and commercial buildings, all purchasers of PVC insulated/ jacketed products should be aware of the following:
  • Non-metallic coverings of electrical cables can burn and may transmit fire when ignited.
  • Burning non-metallic coverings may emit acid gases which are toxic and may generate dense smoke.
  • Emission of acid gases may corrode metal in the vicinity; e.g. sensitive instruments and reinforcing rods in cement.

Related products

Industrial

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close