CIC Tray Cable (TC-ER) ISOS 300V
CIC Tray Cable (TC-ER) ISOS 300V
300V TC-ER Rated Tray Cable Individual and Overall Aluminum Mylar Shielded Tinned Copper Pairs or Triads with Tinned Copper Drain Wires with a PVC Outer Jacket
Read more12PR 300V 16 AWG ISOS CIC TC-ER
Nexans ref. 3XNAISOS16-12PR-P4E
- Packaging: m (1000m)
- Approximate weight: 727 kg/km
- Cable Diameter: 25.2 mm
- Cable Outer Diameter: 0.99 inches
- Conductor size (AWG): 16 AWG
- Number of pairs: 12
- Number of triples: 0
- Weight: 488.521 lb/Mft
- Maximum Pulling Tension: 224.73 kg
- Maximum Pulling Tension: 495.45 pounds
- Minimum Bend Radius - Install: 20.08 cm
- Minimum Bending Radius - Install: 7.91 inches
12PR 300V 18 AWG ISOS CIC TC-ER
Nexans ref. 3XNAISOS18-12PR-P4E
- Packaging: m (1000m)
- Approximate weight: 575 kg/km
- Cable Diameter: 23 mm
- Cable Outer Diameter: 0.91 inches
- Conductor size (AWG): 18 AWG
- Number of pairs: 12
- Number of triples: 0
- Weight: 386.382 lb/Mft
- Maximum Pulling Tension: 140.85 kg
- Maximum Pulling Tension: 310.52 pounds
- Minimum Bend Radius - Install: 16.98 cm
- Minimum Bending Radius - Install: 6.69 inches
1PR 300V 16 AWG OS CIC TC-ER
Nexans ref. 3XNAOS16-1PR-P4E
- Packaging: m (1000m)
- Approximate weight: 79 kg/km
- Cable Diameter: 8.1 mm
- Cable Outer Diameter: 0.32 inches
- Conductor size (AWG): 16 AWG
- Number of pairs: 1
- Number of triples: 0
- Weight: 53.086 lb/Mft
- Maximum Pulling Tension: 18.73 kg
- Maximum Pulling Tension: 41.29 pounds
- Minimum Bend Radius - Install: 6.13 cm
- Minimum Bending Radius - Install: 2.41 inches
1PR 300V 18 AWG OS CIC TC-ER
Nexans ref. 3XNAOS18-1PR-P4E
- Packaging: m (1000m)
- Approximate weight: 65 kg/km
- Cable Diameter: 7.5 mm
- Cable Outer Diameter: 0.29 inches
- Conductor size (AWG): 18 AWG
- Number of pairs: 1
- Number of triples: 0
- Weight: 43.678 lb/Mft
- Maximum Pulling Tension: 11.74 kg
- Maximum Pulling Tension: 25.88 pounds
- Minimum Bend Radius - Install: 5.58 cm
- Minimum Bending Radius - Install: 2.2 inches
1TR 300V 16 AWG OS CIC TC-ER
Nexans ref. 3XNAOS16-1TR-P4E
- Packaging: m (1000m)
- Approximate weight: 98 kg/km
- Cable Diameter: 8.5 mm
- Cable Outer Diameter: 0.34 inches
- Conductor size (AWG): 16 AWG
- Number of pairs: 0
- Number of triples: 1
- Weight: 65.853 lb/Mft
- Maximum Pulling Tension: 28.09 kg
- Maximum Pulling Tension: 61.93 pounds
- Minimum Bend Radius - Install: 6.43 cm
- Minimum Bending Radius - Install: 2.53 inches
1TR 300V 18 AWG OS CIC TC-ER
Nexans ref. 3XNAOS18-1TR-P4E
- Packaging: m (1000m)
- Approximate weight: 79 kg/km
- Cable Diameter: 7.9 mm
- Cable Outer Diameter: 0.31 inches
- Conductor size (AWG): 18 AWG
- Number of pairs: 0
- Number of triples: 1
- Weight: 53.086 lb/Mft
- Maximum Pulling Tension: 17.61 kg
- Maximum Pulling Tension: 38.81 pounds
- Minimum Bend Radius - Install: 5.84 cm
- Minimum Bending Radius - Install: 2.3 inches
2PR 300V 16 AWG ISOS CIC TC-ER
Nexans ref. 3XNAISOS16-2PR-P4E
- Packaging: m (1000m)
- Approximate weight: 185 kg/km
- Cable Diameter: 14.6 mm
- Cable Outer Diameter: 0.57 inches
- Conductor size (AWG): 16 AWG
- Number of pairs: 2
- Number of triples: 0
- Weight: 124.314 lb/Mft
- Maximum Pulling Tension: 37.45 kg
- Maximum Pulling Tension: 82.58 pounds
- Minimum Bend Radius - Install: 10.37 cm
- Minimum Bending Radius - Install: 4.08 inches
2PR 300V 18 AWG ISOS CIC TC-ER
Nexans ref. 3XNAISOS18-2PR-P4E
- Packaging: m (1000m)
- Approximate weight: 132 kg/km
- Cable Diameter: 12.7 mm
- Cable Outer Diameter: 0.5 inches
- Conductor size (AWG): 18 AWG
- Number of pairs: 2
- Number of triples: 0
- Weight: 88.7 lb/Mft
- Maximum Pulling Tension: 23.48 kg
- Maximum Pulling Tension: 51.75 pounds
- Minimum Bend Radius - Install: 9.27 cm
- Minimum Bending Radius - Install: 3.65 inches
2TR 300V 16 AWG ISOS CIC TC-ER
Nexans ref. 3XNAISOS16-2TR-P4E
- Packaging: m (1000m)
- Approximate weight: 227 kg/km
- Cable Diameter: 15.4 mm
- Cable Outer Diameter: 0.61 inches
- Conductor size (AWG): 16 AWG
- Number of pairs: 0
- Number of triples: 2
- Weight: 152.537 lb/Mft
- Maximum Pulling Tension: 56.18 kg
- Maximum Pulling Tension: 123.86 pounds
- Minimum Bend Radius - Install: 11.02 cm
- Minimum Bending Radius - Install: 4.34 inches
2TR 300V 18 AWG ISOS CIC TC-ER
Nexans ref. 3XNAISOS18-2TR-P4E
- Packaging: m (1000m)
- Approximate weight: 185 kg/km
- Cable Diameter: 14.2 mm
- Cable Outer Diameter: 0.56 inches
- Conductor size (AWG): 18 AWG
- Number of pairs: 0
- Number of triples: 2
- Weight: 124.314 lb/Mft
- Maximum Pulling Tension: 35.21 kg
- Maximum Pulling Tension: 77.63 pounds
- Minimum Bend Radius - Install: 9.79 cm
- Minimum Bending Radius - Install: 3.85 inches
3PR 300V 16 AWG ISOS CIC TC-ER
Nexans ref. 3XNAISOS16-3PR-P4E
- Packaging: m (1000m)
- Approximate weight: 234 kg/km
- Cable Diameter: 15.5 mm
- Cable Outer Diameter: 0.61 inches
- Conductor size (AWG): 16 AWG
- Number of pairs: 3
- Number of triples: 0
- Weight: 157.241 lb/Mft
- Maximum Pulling Tension: 56.18 kg
- Maximum Pulling Tension: 123.86 pounds
- Minimum Bend Radius - Install: 11.03 cm
- Minimum Bending Radius - Install: 4.34 inches
3PR 300V 18 AWG ISOS CIC TC-ER
Nexans ref. 3XNAISOS18-3PR-P4E
- Packaging: m (1000m)
- Approximate weight: 191 kg/km
- Cable Diameter: 14.2 mm
- Cable Outer Diameter: 0.56 inches
- Conductor size (AWG): 18 AWG
- Number of pairs: 3
- Number of triples: 0
- Weight: 128.346 lb/Mft
- Maximum Pulling Tension: 35.21 kg
- Maximum Pulling Tension: 77.63 pounds
- Minimum Bend Radius - Install: 9.8 cm
- Minimum Bending Radius - Install: 3.86 inches
4PR 300V 16 AWG ISOS CIC TC-ER
Nexans ref. 3XNAISOS16-4PR-P4E
- Packaging: m (1000m)
- Approximate weight: 275 kg/km
- Cable Diameter: 15.6 mm
- Cable Outer Diameter: 0.61 inches
- Conductor size (AWG): 16 AWG
- Number of pairs: 4
- Number of triples: 0
- Weight: 184.791 lb/Mft
- Maximum Pulling Tension: 74.91 kg
- Maximum Pulling Tension: 165.15 pounds
- Minimum Bend Radius - Install: 12.77 cm
- Minimum Bending Radius - Install: 5.03 inches
4PR 300V 18 AWG ISOS CIC TC-ER
Nexans ref. 3XNAISOS18-4PR-P4E
- Packaging: m (1000m)
- Approximate weight: 222 kg/km
- Cable Diameter: 14.3 mm
- Cable Outer Diameter: 0.56 inches
- Conductor size (AWG): 18 AWG
- Number of pairs: 4
- Number of triples: 0
- Weight: 149.177 lb/Mft
- Maximum Pulling Tension: 46.95 kg
- Maximum Pulling Tension: 103.51 pounds
- Minimum Bend Radius - Install: 10.72 cm
- Minimum Bending Radius - Install: 4.22 inches
4TR 300V 16 AWG ISOS CIC TC-ER
Nexans ref. 3XNAISOS16-4TR-P4E
- Packaging: m (1000m)
- Approximate weight: 376 kg/km
- Cable Diameter: 19.7 mm
- Cable Outer Diameter: 0.78 inches
- Conductor size (AWG): 16 AWG
- Number of pairs: 0
- Number of triples: 4
- Weight: 252.66 lb/Mft
- Maximum Pulling Tension: 112.37 kg
- Maximum Pulling Tension: 247.73 pounds
- Minimum Bend Radius - Install: 14.76 cm
- Minimum Bending Radius - Install: 5.81 inches
4TR 300V 18 AWG ISOS CIC TC-ER
Nexans ref. 3XNAISOS18-4TR-P4E
- Packaging: m (1000m)
- Approximate weight: 298 kg/km
- Cable Diameter: 18 mm
- Cable Outer Diameter: 0.71 inches
- Conductor size (AWG): 18 AWG
- Number of pairs: 0
- Number of triples: 4
- Weight: 200.247 lb/Mft
- Maximum Pulling Tension: 70.42 kg
- Maximum Pulling Tension: 155.26 pounds
- Minimum Bend Radius - Install: 13.17 cm
- Minimum Bending Radius - Install: 5.18 inches
6PR 300V 16 AWG ISOS CIC TC-ER
Nexans ref. 3XNAISOS16-6PR-P4E
- Packaging: m (1000m)
- Approximate weight: 373 kg/km
- Cable Diameter: 17.7 mm
- Cable Outer Diameter: 0.7 inches
- Conductor size (AWG): 16 AWG
- Number of pairs: 6
- Number of triples: 0
- Weight: 250.644 lb/Mft
- Maximum Pulling Tension: 112.37 kg
- Maximum Pulling Tension: 247.73 pounds
- Minimum Bend Radius - Install: 14.44 cm
- Minimum Bending Radius - Install: 5.69 inches
6PR 300V 18 AWG ISOS CIC TC-ER
Nexans ref. 3XNAISOS18-6PR-P4E
- Packaging: m (1000m)
- Approximate weight: 297 kg/km
- Cable Diameter: 16.2 mm
- Cable Outer Diameter: 0.64 inches
- Conductor size (AWG): 18 AWG
- Number of pairs: 6
- Number of triples: 0
- Weight: 199.575 lb/Mft
- Maximum Pulling Tension: 70.42 kg
- Maximum Pulling Tension: 155.26 pounds
- Minimum Bend Radius - Install: 12.89 cm
- Minimum Bending Radius - Install: 5.08 inches
6TR 300V 16 AWG ISOS CIC TC-ER
Nexans ref. 3XNAISOS16-6TR-P4E
- Packaging: m (1000m)
- Approximate weight: 576 kg/km
- Cable Diameter: 24.3 mm
- Cable Outer Diameter: 0.96 inches
- Conductor size (AWG): 16 AWG
- Number of pairs: 0
- Number of triples: 6
- Weight: 387.054 lb/Mft
- Maximum Pulling Tension: 168.55 kg
- Maximum Pulling Tension: 371.59 pounds
- Minimum Bend Radius - Install: 17.39 cm
- Minimum Bending Radius - Install: 6.85 inches
6TR 300V 18 AWG ISOS CIC TC-ER
Nexans ref. 3XNAISOS18-6TR-P4E
- Packaging: m (1000m)
- Approximate weight: 459 kg/km
- Cable Diameter: 22.3 mm
- Cable Outer Diameter: 0.88 inches
- Conductor size (AWG): 18 AWG
- Number of pairs: 0
- Number of triples: 6
- Weight: 308.434 lb/Mft
- Maximum Pulling Tension: 105.64 kg
- Maximum Pulling Tension: 232.89 pounds
- Minimum Bend Radius - Install: 15.44 cm
- Minimum Bending Radius - Install: 6.08 inches
8PR 300V 16 AWG ISOS CIC TC-ER
Nexans ref. 3XNAISOS16-8PR-P4E
- Packaging: m (1000m)
- Approximate weight: 474 kg/km
- Cable Diameter: 20.1 mm
- Cable Outer Diameter: 0.79 inches
- Conductor size (AWG): 16 AWG
- Number of pairs: 8
- Number of triples: 0
- Weight: 318.513 lb/Mft
- Maximum Pulling Tension: 149.82 kg
- Maximum Pulling Tension: 330.3 pounds
- Minimum Bend Radius - Install: 16.4 cm
- Minimum Bending Radius - Install: 6.46 inches
8PR 300V 18 AWG ISOS CIC TC-ER
Nexans ref. 3XNAISOS18-8PR-P4E
- Packaging: m (1000m)
- Approximate weight: 374 kg/km
- Cable Diameter: 18.4 mm
- Cable Outer Diameter: 0.72 inches
- Conductor size (AWG): 18 AWG
- Number of pairs: 8
- Number of triples: 0
- Weight: 251.316 lb/Mft
- Maximum Pulling Tension: 93.9 kg
- Maximum Pulling Tension: 207.01 pounds
- Minimum Bend Radius - Install: 14.59 cm
- Minimum Bending Radius - Install: 5.74 inches
8TR 300V 16 AWG ISOS CIC TC-ER
Nexans ref. 3XNAISOS16-8TR-P4E
- Packaging: m (1000m)
- Approximate weight: 724 kg/km
- Cable Diameter: 27.4 mm
- Cable Outer Diameter: 1.08 inches
- Conductor size (AWG): 16 AWG
- Number of pairs: 0
- Number of triples: 8
- Weight: 486.506 lb/Mft
- Maximum Pulling Tension: 224.73 kg
- Maximum Pulling Tension: 495.45 pounds
- Minimum Bend Radius - Install: 20.53 cm
- Minimum Bending Radius - Install: 8.08 inches
8TR 300V 18 AWG ISOS CIC TC-ER
Nexans ref. 3XNAISOS18-8TR-P4E
- Packaging: m (1000m)
- Approximate weight: 571 kg/km
- Cable Diameter: 25 mm
- Cable Outer Diameter: 0.98 inches
- Conductor size (AWG): 18 AWG
- Number of pairs: 0
- Number of triples: 8
- Weight: 383.694 lb/Mft
- Maximum Pulling Tension: 140.85 kg
- Maximum Pulling Tension: 310.52 pounds
- Minimum Bend Radius - Install: 17.37 cm
- Minimum Bending Radius - Install: 6.84 inches
Description
Description
Standards
-
ProductCSA C22.2 N° 230; CSA C22.2 N° 239; CSA C22.2 N° 2556; CSA C22.2 N° 38
-
TestIEEE 1202; IEEE 383; UL 1685
Applications
Control and Instrumentation Cable manufactured to strict Canadian Standards Association (CSA) requirements, it is a highly rugged, multi-conductor cable designed to transmit analog or digital signals in heavy industrial, harsh, and hazardous environments. Used for connecting PLC (Programmable Logic Controller) systems to field instruments, sensors, valves, and actuators.
- For use in raceways, ventilated, non-ventilated and ladder-type cable trays.
- For dry, damp or wet locations, in ceiling air-handling plenums, direct burial, exposed and concealed wiring.
- For use in Hazardous locations: Zone 0 (intrinsically safe cables only), Zone 2, Zone 22 (per Section 18).
- Cables marked TC-ER tray cable are permitted for exposed runs as per CE Code Part I 12-2202 3) and 4).
Specifications and Compliances
- CSA C22.2 No. 239, Control and instrumentation cables (Type CIC)
- CSA C22.2 No. 38, Thermoset-insulated wires and cables (Type RW90)
- CSA C22.2 No. 230, Tray Cables Exposed Run (TC-ER)
- CSA C22.2 No. 2556 FT4, UL 1685 Vertical-Tray Flame Test
- IEEE 383 & 1202, ICEA T-30-520 (70,000 BTU/hr) Vertical Flame Test rated
- -40°C Cold Bend and -40°C Cold Impact
- Sunlight Resistant, SUN RES. Low Acid Gas, AG14.
Highlights
- Nexans CIC Tray Cable (TC-ER) are: Available from stock
- Versatile & Flexible
- Resistant to Mechanical Abuse and Corrosion
- Compact and Reliable
- 90°C to -40°C
- Low Acid Gas (AG14) • Sunlight resistant
- LEAD FREE & RoHS compliant
- Marked HL to CSA C22.2 No. 174
- FT4 flame spread rating
- HAL-FREE FT4-ST1 available upon request
Marking and Identification
- Black and White Pairs
- Black, White and Red Triads
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania