ACIC US 600V ELCON
ACIC US 600V ELCON
Bare Copper Multiconductor, a PVC Inner Jacket, Aluminum Interlocked Armour and a PVC outer jacket.
Read more10C 600V 16 AWG US ACIC
Nexans ref. 6XAAUS16-10C
- Packaging: m
- Number of conductors: 10
- Approximate weight: 518.89 kg/km
- Armour outer diameter: 0.79 inches
- Cable Diameter: 15.4 mm
- Cable Outer Diameter: 0.61 inches
- Diameter Over Armour: 20.07 mm
- Inner Jacket Diameter: 15.4 mm
- Inner Jacket Outer Diameter: 0.6 inches
- Weight: 348.677 lb/Mft
- Maximum Pulling Tension: 93.64 kg
- Maximum Pulling Tension: 206.44 pounds
- Minimum Bend Radius - Install: 31.65 cm
- Minimum Bending Radius - Install: 12.46 inches
12C 600V 16 AWG US ACIC
Nexans ref. 6XAAUS16-12C
- Packaging: m
- Number of conductors: 12
- Approximate weight: 562.61 kg/km
- Armour outer diameter: 0.88 inches
- Cable Diameter: 15.95 mm
- Cable Outer Diameter: 0.63 inches
- Diameter Over Armour: 22.3 mm
- Inner Jacket Diameter: 16 mm
- Inner Jacket Outer Diameter: 0.6 inches
- Weight: 378.057 lb/Mft
- Maximum Pulling Tension: 112.37 kg
- Maximum Pulling Tension: 247.73 pounds
- Minimum Bend Radius - Install: 32.72 cm
- Minimum Bending Radius - Install: 12.88 inches
15C 600V 16 AWG US ACIC
Nexans ref. 6XAAUS16-15C
- Packaging: m
- Number of conductors: 15
- Approximate weight: 638.42 kg/km
- Armour outer diameter: 0.96 inches
- Cable Diameter: 18.52 mm
- Cable Outer Diameter: 0.73 inches
- Diameter Over Armour: 24.31 mm
- Inner Jacket Diameter: 18.5 mm
- Inner Jacket Outer Diameter: 0.7 inches
- Weight: 428.997 lb/Mft
- Maximum Pulling Tension: 140.46 kg
- Maximum Pulling Tension: 309.66 pounds
- Minimum Bend Radius - Install: 34.85 cm
- Minimum Bending Radius - Install: 13.72 inches
20C 600V 16 AWG US ACIC
Nexans ref. 6XAAUS16-20C
- Packaging: m
- Number of conductors: 20
- Approximate weight: 769.63 kg/km
- Armour outer diameter: 1.04 inches
- Cable Diameter: 19.29 mm
- Cable Outer Diameter: 0.76 inches
- Diameter Over Armour: 26.42 mm
- Inner Jacket Diameter: 19.3 mm
- Inner Jacket Outer Diameter: 0.8 inches
- Weight: 517.169 lb/Mft
- Maximum Pulling Tension: 187.28 kg
- Maximum Pulling Tension: 412.88 pounds
- Minimum Bend Radius - Install: 39.12 cm
- Minimum Bending Radius - Install: 15.4 inches
2C 600V 16 AWG US ACIC
Nexans ref. 6XAAUS16-2C
- Packaging: m
- Number of conductors: 3
- Approximate weight: 237.09 kg/km
- Armour outer diameter: 0.53 inches
- Cable Diameter: 8.67 mm
- Cable Outer Diameter: 0.34 inches
- Diameter Over Armour: 13.46 mm
- Inner Jacket Diameter: 8.7 mm
- Inner Jacket Outer Diameter: 0.3 inches
- Weight: 159.319 lb/Mft
- Maximum Pulling Tension: 18.73 kg
- Maximum Pulling Tension: 41.29 pounds
- Minimum Bend Radius - Install: 22.4 cm
- Minimum Bending Radius - Install: 8.82 inches
30C 600V 16 AWG US ACIC
Nexans ref. 6XAAUS16-30C
- Packaging: m
- Number of conductors: 30
- Approximate weight: 1073.05 kg/km
- Armour outer diameter: 1.15 inches
- Cable Diameter: 23.62 mm
- Cable Outer Diameter: 0.93 inches
- Diameter Over Armour: 29.21 mm
- Inner Jacket Diameter: 23.6 mm
- Inner Jacket Outer Diameter: 0.9 inches
- Weight: 721.059 lb/Mft
- Maximum Pulling Tension: 280.92 kg
- Maximum Pulling Tension: 619.32 pounds
- Minimum Bend Radius - Install: 44.45 cm
- Minimum Bending Radius - Install: 17.5 inches
3C 600V 16 AWG US ACIC
Nexans ref. 6XAAUS16-3C
- Packaging: m
- Number of conductors: 4
- Approximate weight: 263.26 kg/km
- Armour outer diameter: 0.58 inches
- Cable Diameter: 9.12 mm
- Cable Outer Diameter: 0.36 inches
- Diameter Over Armour: 14.73 mm
- Inner Jacket Diameter: 9.1 mm
- Inner Jacket Outer Diameter: 0.4 inches
- Weight: 176.906 lb/Mft
- Maximum Pulling Tension: 28.09 kg
- Maximum Pulling Tension: 61.93 pounds
- Minimum Bend Radius - Install: 24.18 cm
- Minimum Bending Radius - Install: 9.52 inches
40C 600V 16 AWG US ACIC
Nexans ref. 6XAAUS16-40C
- Packaging: m
- Number of conductors: 40
- Approximate weight: 1305.74 kg/km
- Armour outer diameter: 1.32 inches
- Cable Diameter: 26.28 mm
- Cable Outer Diameter: 1.03 inches
- Diameter Over Armour: 33.53 mm
- Inner Jacket Diameter: 26.3 mm
- Inner Jacket Outer Diameter: 1 inches
- Weight: 877.417 lb/Mft
- Maximum Pulling Tension: 374.56 kg
- Maximum Pulling Tension: 825.75 pounds
- Minimum Bend Radius - Install: 50.49 cm
- Minimum Bending Radius - Install: 19.88 inches
4C 600V 16 AWG US ACIC
Nexans ref. 6XAAUS16-4C
- Packaging: m
- Number of conductors: 5
- Approximate weight: 294.64 kg/km
- Armour outer diameter: 0.62 inches
- Cable Diameter: 9.89 mm
- Cable Outer Diameter: 0.39 inches
- Diameter Over Armour: 15.75 mm
- Inner Jacket Diameter: 9.9 mm
- Inner Jacket Outer Diameter: 0.4 inches
- Weight: 197.991 lb/Mft
- Maximum Pulling Tension: 37.46 kg
- Maximum Pulling Tension: 82.58 pounds
- Minimum Bend Radius - Install: 25.6 cm
- Minimum Bending Radius - Install: 10.08 inches
50C 600V 16 AWG US ACIC
Nexans ref. 6XAAUS16-50C
- Packaging: m
- Number of conductors: 50
- Approximate weight: 1541.67 kg/km
- Armour outer diameter: 1.45 inches
- Cable Diameter: 29.08 mm
- Cable Outer Diameter: 1.15 inches
- Diameter Over Armour: 36.83 mm
- Inner Jacket Diameter: 29.1 mm
- Inner Jacket Outer Diameter: 1.1 inches
- Weight: 1035.961 lb/Mft
- Maximum Pulling Tension: 468.19 kg
- Maximum Pulling Tension: 1032.19 pounds
- Minimum Bend Radius - Install: 55.12 cm
- Minimum Bending Radius - Install: 21.7 inches
5C 600V 16 AWG US ACIC
Nexans ref. 6XAAUS16-5C
- Packaging: m
- Number of conductors: 6
- Approximate weight: 327.62 kg/km
- Armour outer diameter: 0.63 inches
- Cable Diameter: 10.76 mm
- Cable Outer Diameter: 0.42 inches
- Diameter Over Armour: 16.0 mm
- Inner Jacket Diameter: 10.8 mm
- Inner Jacket Outer Diameter: 0.4 inches
- Weight: 220.153 lb/Mft
- Maximum Pulling Tension: 46.82 kg
- Maximum Pulling Tension: 103.22 pounds
- Minimum Bend Radius - Install: 25.96 cm
- Minimum Bending Radius - Install: 10.22 inches
6C 600V 16 AWG US ACIC
Nexans ref. 6XAAUS16-6C
- Packaging: m
- Number of conductors: 7
- Approximate weight: 361.14 kg/km
- Armour outer diameter: 0.64 inches
- Cable Diameter: 11.5 mm
- Cable Outer Diameter: 0.45 inches
- Diameter Over Armour: 16.26 mm
- Inner Jacket Diameter: 11.5 mm
- Inner Jacket Outer Diameter: 0.5 inches
- Weight: 242.674 lb/Mft
- Maximum Pulling Tension: 56.18 kg
- Maximum Pulling Tension: 123.86 pounds
- Minimum Bend Radius - Install: 26.31 cm
- Minimum Bending Radius - Install: 10.36 inches
7C 600V 16 AWG US ACIC
Nexans ref. 6XAAUS16-7C
- Packaging: m
- Number of conductors: 2
- Approximate weight: 378.62 kg/km
- Armour outer diameter: 0.66 inches
- Cable Diameter: 11.65 mm
- Cable Outer Diameter: 0.46 inches
- Diameter Over Armour: 16.76 mm
- Inner Jacket Diameter: 11.7 mm
- Inner Jacket Outer Diameter: 0.5 inches
- Weight: 254.42 lb/Mft
- Maximum Pulling Tension: 65.55 kg
- Maximum Pulling Tension: 144.51 pounds
- Minimum Bend Radius - Install: 27.03 cm
- Minimum Bending Radius - Install: 10.64 inches
8C 600V 16 AWG US ACIC
Nexans ref. 6XAAUS16-8C
- Packaging: m
- Number of conductors: 8
- Approximate weight: 412.13 kg/km
- Armour outer diameter: 0.74 inches
- Cable Diameter: 12.55 mm
- Cable Outer Diameter: 0.49 inches
- Diameter Over Armour: 18.8 mm
- Inner Jacket Diameter: 12.6 mm
- Inner Jacket Outer Diameter: 0.5 inches
- Weight: 276.941 lb/Mft
- Maximum Pulling Tension: 74.91 kg
- Maximum Pulling Tension: 165.15 pounds
- Minimum Bend Radius - Install: 29.87 cm
- Minimum Bending Radius - Install: 11.76 inches
9C 600V 16 AWG US ACIC
Nexans ref. 6XAAUS16-9C
- Packaging: m
- Number of conductors: 9
- Approximate weight: 478.62 kg/km
- Armour outer diameter: 0.77 inches
- Cable Diameter: 14.24 mm
- Cable Outer Diameter: 0.56 inches
- Diameter Over Armour: 19.5 mm
- Inner Jacket Diameter: 14.2 mm
- Inner Jacket Outer Diameter: 0.6 inches
- Weight: 321.621 lb/Mft
- Maximum Pulling Tension: 84.28 kg
- Maximum Pulling Tension: 185.79 pounds
- Minimum Bend Radius - Install: 30.86 cm
- Minimum Bending Radius - Install: 12.15 inches
Description
Description
Standards
-
ProductCSA C22.2 N° 239; CSA C22.2 N° 174; CSA C22.2 N° 2556; CSA C22.2 N° 38
-
TestICEA T-30 520; IEEE 1202; IEEE 383; UL 1685
Applications
Armoured Control and Instrumentation Cable manufactured to strict Canadian Standards Association (CSA) requirements, it is a highly rugged, multi-conductor cable designed to transmit analog or digital signals in heavy industrial, harsh, and hazardous environments. Used for connecting PLC (Programmable Logic Controller) systems to field instruments, sensors, valves, and actuators.
- For use in raceways, ventilated, non-ventilated and ladder-type cable trays.
- For dry, damp or wet locations, in ceiling air-handling plenums, direct burial, exposed and concealed wiring.
- Approved for all Hazardous Locations (HL) as per CE Code Part I 2024 Section 18, when installed with approved connectors.
Specifications and Compliances
- CSA C22.2 No. 239, Control and instrumentation cables (Type ACIC)
- CSA C22.2 No. 38, Thermoset-insulated wires and cables (Type RW90)
- CSA C22.2 No. 174, Cables and cable glands for use in hazardous locations (HL)
- CSA C22.2 No. 2556 FT4, UL 1685 Vertical-Tray Flame Test IEEE 383 & 1202, ICEA T-30-520 (70,000 BTU/hr) Vertical Flame Test rated
- -40°C Cold Bend and -40°C Cold Impact
- Sunlight Resistant, SUN RES and Low Acid Gas, AG14
Highlights
- Nexans ACIC Cables are: Available from stock
- Versatile & Flexible
- Resistant to Mechanical Abuse and Corrosion
- Compact and Reliable
- 90°C to -40°C
- Low Acid Gas (AG14) • Sunlight resistant
- LEAD FREE & RoHS compliant
- Marked HL to CSA C22.2 No. 174
- FT4 flame spread rating
- HAL-FREE FT4-ST1 available upon request
Marking and Identification
- Black and White Pairs
- Black, White and Red Triads
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania