- About Us
 - Product Datasheets
 - Products Overview
 - Services and Solutions
 - News
 - Tools & Documents
 - 
					        Webinars
					        
- Webinars
 - Understanding DriveRx® VFD Cables
 - Exploring Wire and Cable Used in Data Centres
 - Exploring Wire and Cable Used in Healthcare
 - Key 2024 CE Code Changes Impacting Wire and Cable
 - Industrial Power Cables: Conductors in Shining Armour
 - Sustainability In the Wire & Cable Industry
 - Copper Demands and Recycling
 - Wiring for Canadian Homes - Part 3
 - Medium Voltage Solutions for Solar Applications
 - Wiring for Canadian Homes - Part 2
 - Wiring for Canadian Homes - Part 1
 - Cable Manufacturing
 - REEL Talk
 - ULTRACKER Connected Reels Tracking Solution
 - Installations 102
 - Installations 101
 - Copper & Aluminum: What You Need to Know
 - Cables 101
 - Raw Material Insights
 - Renewable Energy - Wind & Solar Energy Trends
 - Emerging Trends for Utility Cables
 - Key 2021 Electrical Code Changes Impacting Wire and Cable
 
 - Search
 - Contact us
 - Compare
 - Sign in
 
2C12(1) NMD90 CU CANADEX YELLOW 150M
2C12(1) NMD90 CU CANADEX YELLOW 150M
| CANADEX | 
Residential cable
Read more- Nexans ref. : 12000017
 - Country ref. : 347427
 - EAN : 622089103870
 
Description
Description
Standards
- 
                                            ProductCSA C22.2 N° 48
 
CSA File #LL23462 Class 5821 02
Two or three copper conductors with 90ºC PVC and nylon insulation.
Bare bonding wire and overall jacket of moisture resistant and flame retardant PVC, with FT1 rating.
LEAD FREE.
Nexans NMD90 CANADEX® Jacket colours:
#14 AWG - White 2 & 3C #14 for General Application
          - Blue 2C#14 for Bedroom Outlets terminating at Arc Fault Circuit Interrupters (AFCI)
#12 AWG - Yellow
#10 AWG - Orange
#8 AWG and larger - White
NMD90 CANADEX® Insulation colours:
2 Conductors - Black, White
3 Conductors - Black, Red, White
Residential Applications for NMD90 CANADEX® :
- For open or concealed wiring in dry or damp locations where not exposed to mechanical injury.
 - Maximum conductor temperature 90°C.
 - Approved for use with ceiling fixtures.
 - Minimum recommended handling temperature minus 25°C for 2 conductor cables and minus 10°C for 3 conductor cables (with suitable handling procedures).
 
Characteristics
Characteristics
Construction characteristics
Construction characteristics
                                                                Conductor Material
                                                            
                                                            
                                                                Copper 
                                                            
                                                        
                                                                Insulation
                                                            
                                                            
                                                                PVC/Nylon 
                                                            
                                                        
                                                                Insulation Colour
                                                            
                                                            
                                                                Yellow 
                                                            
                                                        
                                                                Number of conductors
                                                            
                                                            
                                                                2 
                                                            
                                                        
                                                                With Bonding Conductor
                                                            
                                                            
                                                                Yes 
                                                            
                                                        Dimensional characteristics
Dimensional characteristics
                                                                Approximate Net Weight
                                                            
                                                            
                                                                121 kg/km
                                                            
                                                        
                                                                Bare Ground Size (AWG)
                                                            
                                                            
                                                                14 
                                                            
                                                        
                                                                Conductor Diameter (mm)
                                                            
                                                            
                                                                2.32 
                                                            
                                                        
                                                                Conductor size (AWG)
                                                            
                                                            
                                                                12 AWG 
                                                            
                                                        
                                                                External dimensions
                                                            
                                                            
                                                                5.3 x 10.7 mm 
                                                            
                                                        
                                                                Jacket Thickness
                                                            
                                                            
                                                                0.76 mm
                                                            
                                                        
                                                                Nominal insulation thickness
                                                            
                                                            
                                                                0.76 mm
                                                            
                                                        
                                                                Number of Conductors
                                                            
                                                            
                                                                2 
                                                            
                                                        
                                                                Number of Strands
                                                            
                                                            
                                                                1 
                                                            
                                                        
                                                                Nylon thickness
                                                            
                                                            
                                                                0.1 mm
                                                            
                                                        Electrical characteristics
Electrical characteristics
                                                                Maximum operating voltage
                                                            
                                                            
                                                                300 V
                                                            
                                                        Usage characteristics
Usage characteristics
                                                                Maximum operating temperature
                                                            
                                                            
                                                                90 °C
                                                            
                                                        
                                                                Minimum installation temperature
                                                            
                                                            
                                                                -25 °C
                                                            