- About Us
- Product Datasheets
- Products Overview
- Services and Solutions
- News
- Tools & Documents
-
Webinars
- Webinars
- Understanding North American Medium Voltage Cable Standards
- Understanding DriveRx® VFD Cables
- Exploring Wire and Cable Used in Data Centres
- Exploring Wire and Cable Used in Healthcare
- Key 2024 CE Code Changes Impacting Wire and Cable
- Industrial Power Cables: Conductors in Shining Armour
- Sustainability In the Wire & Cable Industry
- Copper Demands and Recycling
- Wiring for Canadian Homes - Part 3
- Medium Voltage Solutions for Solar Applications
- Wiring for Canadian Homes - Part 2
- Wiring for Canadian Homes - Part 1
- Cable Manufacturing
- REEL Talk
- ULTRACKER Connected Reels Tracking Solution
- Installations 102
- Installations 101
- Copper & Aluminum: What You Need to Know
- Cables 101
- Raw Material Insights
- Renewable Energy - Wind & Solar Energy Trends
- Emerging Trends for Utility Cables
- Search
- Contact us
- Compare
- Sign in
ACIC ISOS 600V
ACIC ISOS 600V
Individual and Overall Aluminum Mylar Shielded Tinned Copper Pairs or Triads with Tinned Copper Drain Wires, a PVC Inner Jacket, Aluminum Interlocked Armour and a PVC outer jacket.
Read more12PR 600v 16 AWG ISOS ACIC
Nexans ref. 6XAAISOS16-12PR
- Packaging: m
- Approximate weight: 1271 kg/km
- Armour outer diameter: 38.58 inches
- Cable Diameter: 38.58 mm
- Cable Outer Diameter: 1.52 inches
- Conductor size (AWG): 16 AWG
- Diameter Over Armour: 1.11 mm
- Inner Jacket Diameter: 24.2 mm
- Inner Jacket Outer Diameter: 1 inches
- Number of pairs: 12
- Number of triples: 0
- Weight: 854 lb/Mft
- Maximum Pulling Tension: 224.75 kg
- Maximum Pulling Tension: 495.48 pounds
- Minimum Bend Radius - Install: 54.1 cm
- Minimum Bending Radius - Install: 21.3 inches
12PR 600v 18 AWG ISOS ACIC
Nexans ref. 6XAAISOS18-12PR
- Packaging: m
- Approximate weight: 1070 kg/km
- Armour outer diameter: 25.9 inches
- Cable Diameter: 34.8 mm
- Cable Outer Diameter: 1.37 inches
- Conductor size (AWG): 18 AWG
- Diameter Over Armour: 1.02 mm
- Inner Jacket Diameter: 21.8 mm
- Inner Jacket Outer Diameter: 0.9 inches
- Number of pairs: 12
- Number of triples: 0
- Weight: 718.933 lb/Mft
- Maximum Pulling Tension: 141 kg
- Maximum Pulling Tension: 311 pounds
- Minimum Bend Radius - Install: 48.65 cm
- Minimum Bending Radius - Install: 19.15 inches
1PR 600v 16 AWG ISOS ACIC
Nexans ref. 6XAAOS16-1PR
- Packaging: m
- Approximate weight: 226 kg/km
- Armour outer diameter: 15.9 inches
- Cable Diameter: 15.9 mm
- Cable Outer Diameter: 0.63 inches
- Conductor size (AWG): 16 AWG
- Diameter Over Armour: 0.33 mm
- Inner Jacket Diameter: 6 mm
- Inner Jacket Outer Diameter: 0.2 inches
- Number of pairs: 1
- Number of triples: 0
- Weight: 152 lb/Mft
- Maximum Pulling Tension: 18.73 kg
- Maximum Pulling Tension: 41.29 pounds
- Minimum Bend Radius - Install: 22.35 cm
- Minimum Bending Radius - Install: 8.8 inches
1PR 600v 18 AWG ISOS ACIC NEW
Nexans ref. 6XAAOS18-1PR
- Packaging: m
- Approximate weight: 204 kg/km
- Armour outer diameter: 7.7 inches
- Cable Diameter: 15.3 mm
- Cable Outer Diameter: 0.6 inches
- Conductor size (AWG): 18 AWG
- Diameter Over Armour: 0.3 mm
- Inner Jacket Diameter: 5.4 mm
- Inner Jacket Outer Diameter: 0.2 inches
- Number of pairs: 1
- Number of triples: 0
- Weight: 137.068 lb/Mft
- Maximum Pulling Tension: 12 kg
- Maximum Pulling Tension: 26 pounds
- Minimum Bend Radius - Install: 21.41 cm
- Minimum Bending Radius - Install: 8.43 inches
1TR 600v 16 AWG ISOS ACIC
Nexans ref. 6XAAOS16-1TR
- Packaging: m
- Approximate weight: 252 kg/km
- Armour outer diameter: 16.36 inches
- Cable Diameter: 16.36 mm
- Cable Outer Diameter: 0.64 inches
- Conductor size (AWG): 16 AWG
- Diameter Over Armour: 0.35 mm
- Inner Jacket Diameter: 6.5 mm
- Inner Jacket Outer Diameter: 0.3 inches
- Number of pairs: 0
- Number of triples: 1
- Weight: 169 lb/Mft
- Maximum Pulling Tension: 28.09 kg
- Maximum Pulling Tension: 61.93 pounds
- Minimum Bend Radius - Install: 22.9 cm
- Minimum Bending Radius - Install: 9.02 inches
1TR 600v 18 AWG ISOS ACIC
Nexans ref. 6XAAOS18-1TR
- Packaging: m
- Approximate weight: 224 kg/km
- Armour outer diameter: 8.1 inches
- Cable Diameter: 15.7 mm
- Cable Outer Diameter: 0.62 inches
- Conductor size (AWG): 18 AWG
- Diameter Over Armour: 0.32 mm
- Inner Jacket Diameter: 5.8 mm
- Inner Jacket Outer Diameter: 0.2 inches
- Number of pairs: 0
- Number of triples: 1
- Weight: 150 lb/Mft
- Maximum Pulling Tension: 18 kg
- Maximum Pulling Tension: 39 pounds
- Minimum Bend Radius - Install: 21.98 cm
- Minimum Bending Radius - Install: 8.65 inches
2PR 600v 16 AWG ISOS ACIC
Nexans ref. 6XAAISOS16-2PR
- Packaging: m
- Approximate weight: 423 kg/km
- Armour outer diameter: 22.86 inches
- Cable Diameter: 22.86 mm
- Cable Outer Diameter: 0.9 inches
- Conductor size (AWG): 16 AWG
- Diameter Over Armour: 0.6 mm
- Inner Jacket Diameter: 12.2 mm
- Inner Jacket Outer Diameter: 0.5 inches
- Number of pairs: 2
- Number of triples: 0
- Weight: 284 lb/Mft
- Maximum Pulling Tension: 37.46 kg
- Maximum Pulling Tension: 82.58 pounds
- Minimum Bend Radius - Install: 32 cm
- Minimum Bending Radius - Install: 12.6 inches
2PR 600v 18 AWG ISOS ACIC
Nexans ref. 6XAAISOS18-2PR
- Packaging: m
- Approximate weight: 377 kg/km
- Armour outer diameter: 14.1 inches
- Cable Diameter: 21.6 mm
- Cable Outer Diameter: 0.85 inches
- Conductor size (AWG): 18 AWG
- Diameter Over Armour: 0.55 mm
- Inner Jacket Diameter: 11 mm
- Inner Jacket Outer Diameter: 0.4 inches
- Number of pairs: 2
- Number of triples: 0
- Weight: 253.306 lb/Mft
- Maximum Pulling Tension: 23 kg
- Maximum Pulling Tension: 52 pounds
- Minimum Bend Radius - Install: 30.3 cm
- Minimum Bending Radius - Install: 11.93 inches
2TR 600v 16 AWG ISOS ACIC
Nexans ref. 6XAAISOS16-2TR
- Packaging: m
- Approximate weight: 478 kg/km
- Armour outer diameter: 23.75 inches
- Cable Diameter: 23.75 mm
- Cable Outer Diameter: 0.94 inches
- Conductor size (AWG): 16 AWG
- Diameter Over Armour: 0.64 mm
- Inner Jacket Diameter: 13.1 mm
- Inner Jacket Outer Diameter: 0.5 inches
- Number of pairs: 0
- Number of triples: 2
- Weight: 321 lb/Mft
- Maximum Pulling Tension: 56.18 kg
- Maximum Pulling Tension: 123.86 pounds
- Minimum Bend Radius - Install: 33.25 cm
- Minimum Bending Radius - Install: 13.09 inches
2TR 600v 18 AWG ISOS ACIC
Nexans ref. 6XAAISOS18-2TR
- Packaging: m
- Approximate weight: 419 kg/km
- Armour outer diameter: 14.9 inches
- Cable Diameter: 22.4 mm
- Cable Outer Diameter: 0.88 inches
- Conductor size (AWG): 18 AWG
- Diameter Over Armour: 0.59 mm
- Inner Jacket Diameter: 11.8 mm
- Inner Jacket Outer Diameter: 0.5 inches
- Number of pairs: 0
- Number of triples: 2
- Weight: 281.526 lb/Mft
- Maximum Pulling Tension: 35 kg
- Maximum Pulling Tension: 78 pounds
- Minimum Bend Radius - Install: 31.43 cm
- Minimum Bending Radius - Install: 12.38 inches
4PR 600v 16AWG ISOS ACIC
Nexans ref. 6XAAISOS16-4PR
- Packaging: m
- Approximate weight: 561 kg/km
- Armour outer diameter: 26.16 inches
- Cable Diameter: 26.16 mm
- Cable Outer Diameter: 1.03 inches
- Conductor size (AWG): 16 AWG
- Diameter Over Armour: 0.7 mm
- Inner Jacket Diameter: 14.7 mm
- Inner Jacket Outer Diameter: 0.6 inches
- Number of pairs: 4
- Number of triples: 0
- Weight: 377 lb/Mft
- Maximum Pulling Tension: 74.92 kg
- Maximum Pulling Tension: 165.16 pounds
- Minimum Bend Radius - Install: 36.58 cm
- Minimum Bending Radius - Install: 14.4 inches
4PR 600v 18 AWG ISOS ACIC
Nexans ref. 6XAAISOS18-4PR
- Packaging: m
- Approximate weight: 483 kg/km
- Armour outer diameter: 16.3 inches
- Cable Diameter: 23.9 mm
- Cable Outer Diameter: 0.94 inches
- Conductor size (AWG): 18 AWG
- Diameter Over Armour: 0.64 mm
- Inner Jacket Diameter: 13.3 mm
- Inner Jacket Outer Diameter: 0.5 inches
- Number of pairs: 4
- Number of triples: 0
- Weight: 324.528 lb/Mft
- Maximum Pulling Tension: 47 kg
- Maximum Pulling Tension: 104 pounds
- Minimum Bend Radius - Install: 33.43 cm
- Minimum Bending Radius - Install: 13.16 inches
4TR 600v 16 AWG ISOS ACIC
Nexans ref. 6XAAISOS16-4TR
- Packaging: m
- Approximate weight: 693 kg/km
- Armour outer diameter: 29.11 inches
- Cable Diameter: 29.11 mm
- Cable Outer Diameter: 1.15 inches
- Conductor size (AWG): 16 AWG
- Diameter Over Armour: 0.82 mm
- Inner Jacket Diameter: 17.7 mm
- Inner Jacket Outer Diameter: 0.7 inches
- Number of pairs: 0
- Number of triples: 4
- Weight: 466 lb/Mft
- Maximum Pulling Tension: 112.37 kg
- Maximum Pulling Tension: 247.73 pounds
- Minimum Bend Radius - Install: 40.75 cm
- Minimum Bending Radius - Install: 16.04 inches
4TR 600v 18 AWG ISOS ACIC
Nexans ref. 6XAAISOS18-4TR
- Packaging: m
- Approximate weight: 592 kg/km
- Armour outer diameter: 19.0 inches
- Cable Diameter: 27.3 mm
- Cable Outer Diameter: 1.08 inches
- Conductor size (AWG): 18 AWG
- Diameter Over Armour: 0.75 mm
- Inner Jacket Diameter: 15.9 mm
- Inner Jacket Outer Diameter: 0.6 inches
- Number of pairs: 0
- Number of triples: 4
- Weight: 398 lb/Mft
- Maximum Pulling Tension: 70 kg
- Maximum Pulling Tension: 155 pounds
- Minimum Bend Radius - Install: 38.3 cm
- Minimum Bending Radius - Install: 15.08 inches
6PR 600v 16 AWG ISOS ACIC
Nexans ref. 6XAAISOS16-6PR
- Packaging: m
- Approximate weight: 693 kg/km
- Armour outer diameter: 28.63 inches
- Cable Diameter: 28.63 mm
- Cable Outer Diameter: 1.13 inches
- Conductor size (AWG): 16 AWG
- Diameter Over Armour: 0.8 mm
- Inner Jacket Diameter: 17.2 mm
- Inner Jacket Outer Diameter: 0.7 inches
- Number of pairs: 6
- Number of triples: 0
- Weight: 466 lb/Mft
- Maximum Pulling Tension: 112.37 kg
- Maximum Pulling Tension: 247.74 pounds
- Minimum Bend Radius - Install: 40.13 cm
- Minimum Bending Radius - Install: 15.8 inches
6PR 600v 18 AWG ISOS ACIC
Nexans ref. 6XAAISOS18-6PR
- Packaging: m
- Approximate weight: 593 kg/km
- Armour outer diameter: 18.5 inches
- Cable Diameter: 26.9 mm
- Cable Outer Diameter: 1.06 inches
- Conductor size (AWG): 18 AWG
- Diameter Over Armour: 0.73 mm
- Inner Jacket Diameter: 15.5 mm
- Inner Jacket Outer Diameter: 0.6 inches
- Number of pairs: 6
- Number of triples: 0
- Weight: 399 lb/Mft
- Maximum Pulling Tension: 70 kg
- Maximum Pulling Tension: 155 pounds
- Minimum Bend Radius - Install: 37.69 cm
- Minimum Bending Radius - Install: 14.84 inches
6TR 600v 16 AWG ISOS ACIC
Nexans ref. 6XAAISOS16-6TR
- Packaging: m
- Approximate weight: 1057 kg/km
- Armour outer diameter: 34.54 inches
- Cable Diameter: 34.54 mm
- Cable Outer Diameter: 1.36 inches
- Conductor size (AWG): 16 AWG
- Diameter Over Armour: 1.01 mm
- Inner Jacket Diameter: 21.6 mm
- Inner Jacket Outer Diameter: 0.8 inches
- Number of pairs: 0
- Number of triples: 6
- Weight: 710 lb/Mft
- Maximum Pulling Tension: 168.55 kg
- Maximum Pulling Tension: 371.59 pounds
- Minimum Bend Radius - Install: 48.36 cm
- Minimum Bending Radius - Install: 19.04 inches
6TR 600v 18 AWG ISOS ACIC
Nexans ref. 6XAAISOS18-6TR
- Packaging: m
- Approximate weight: 813 kg/km
- Armour outer diameter: 23.5 inches
- Cable Diameter: 31.9 mm
- Cable Outer Diameter: 1.25 inches
- Conductor size (AWG): 18 AWG
- Diameter Over Armour: 0.93 mm
- Inner Jacket Diameter: 19.4 mm
- Inner Jacket Outer Diameter: 0.8 inches
- Number of pairs: 0
- Number of triples: 6
- Weight: 546 lb/Mft
- Maximum Pulling Tension: 106 kg
- Maximum Pulling Tension: 233 pounds
- Minimum Bend Radius - Install: 44.63 cm
- Minimum Bending Radius - Install: 17.57 inches
8PR 600v 16 AWG ISOS ACIC
Nexans ref. 6XAAISOS16-8PR
- Packaging: m
- Approximate weight: 992 kg/km
- Armour outer diameter: 33.07 inches
- Cable Diameter: 33.07 mm
- Cable Outer Diameter: 1.3 inches
- Conductor size (AWG): 16 AWG
- Diameter Over Armour: 0.95 mm
- Inner Jacket Diameter: 20.1 mm
- Inner Jacket Outer Diameter: 0.8 inches
- Number of pairs: 8
- Number of triples: 0
- Weight: 667 lb/Mft
- Maximum Pulling Tension: 149.83 kg
- Maximum Pulling Tension: 330.32 pounds
- Minimum Bend Radius - Install: 46.23 cm
- Minimum Bending Radius - Install: 18.2 inches
8PR 600v 18 AWG ISOS ACIC
Nexans ref. 6XAAISOS18-8PR
- Packaging: m
- Approximate weight: 768 kg/km
- Armour outer diameter: 22.2 inches
- Cable Diameter: 30.5 mm
- Cable Outer Diameter: 1.2 inches
- Conductor size (AWG): 18 AWG
- Diameter Over Armour: 0.87 mm
- Inner Jacket Diameter: 18.1 mm
- Inner Jacket Outer Diameter: 0.7 inches
- Number of pairs: 8
- Number of triples: 0
- Weight: 516.019 lb/Mft
- Maximum Pulling Tension: 94 kg
- Maximum Pulling Tension: 207 pounds
- Minimum Bend Radius - Install: 42.74 cm
- Minimum Bending Radius - Install: 16.83 inches
8TR 600v 16 AWG ISOS ACIC
Nexans ref. 6XAAISOS16-8TR
- Packaging: m
- Approximate weight: 1268 kg/km
- Armour outer diameter: 39.24 inches
- Cable Diameter: 39.24 mm
- Cable Outer Diameter: 1.54 inches
- Conductor size (AWG): 16 AWG
- Diameter Over Armour: 1.14 mm
- Inner Jacket Diameter: 24.9 mm
- Inner Jacket Outer Diameter: 1 inches
- Number of pairs: 0
- Number of triples: 8
- Weight: 852 lb/Mft
- Maximum Pulling Tension: 224.73 kg
- Maximum Pulling Tension: 495.45 pounds
- Minimum Bend Radius - Install: 54.94 cm
- Minimum Bending Radius - Install: 21.63 inches
8TR 600v 18 AWG ISOS ACIC
Nexans ref. 6XAAISOS18-8TR
- Packaging: m
- Approximate weight: 1066 kg/km
- Armour outer diameter: 26.5 inches
- Cable Diameter: 35.4 mm
- Cable Outer Diameter: 1.39 inches
- Conductor size (AWG): 18 AWG
- Diameter Over Armour: 1.04 mm
- Inner Jacket Diameter: 22.4 mm
- Inner Jacket Outer Diameter: 0.9 inches
- Number of pairs: 0
- Number of triples: 8
- Weight: 717 lb/Mft
- Maximum Pulling Tension: 141 kg
- Maximum Pulling Tension: 311 pounds
- Minimum Bend Radius - Install: 49.5 cm
- Minimum Bending Radius - Install: 19.49 inches
Description
Description
Standards
-
ProductCSA C22.2 N° 239; CSA C22.2 N° 174; CSA C22.2 N° 2556; CSA C22.2 N° 38
-
TestICEA T-30 520; IEEE 1202; IEEE 383; UL 1685
Applications
Armoured Control and Instrumentation Cable manufactured to strict Canadian Standards Association (CSA) requirements, it is a highly rugged, multi-conductor cable designed to transmit analog or digital signals in heavy industrial, harsh, and hazardous environments. Used for connecting PLC (Programmable Logic Controller) systems to field instruments, sensors, valves, and actuators.
- For use in raceways, ventilated, non-ventilated and ladder-type cable trays.
- For dry, damp or wet locations, in ceiling air-handling plenums, direct burial, exposed and concealed wiring.
- Approved for all Hazardous Locations (HL-ABCD) as per CE Code Part I 2024 Section 18, when installed with approved connectors.
Specifications and Compliances
- CSA C22.2 No. 239, Control and instrumentation cables (Type ACIC)
- CSA C22.2 No. 38, Thermoset-insulated wires and cables (Type RW90)
- CSA C22.2 No. 174, Cables and cable glands for use in hazardous locations (HL-ABCD)
- CSA C22.2 No. 2556 FT4, UL 1685 Vertical-Tray Flame Test IEEE 383 & 1202, ICEA T-30-520 (70,000 BTU/hr) Vertical Flame Test rated
- -40°C Cold Bend and -40°C Cold Impact
- Sunlight Resistant, SUN RES and Low Acid Gas, AG14
Highlights
- Nexans ACIC Cables are: Available from stock
- Versatile & Flexible
- Resistant to Mechanical Abuse and Corrosion
- Compact and Reliable
- 90°C to -40°C
- Low Acid Gas (AG14) • Sunlight resistant
- LEAD FREE & RoHS compliant
- Marked HL to CSA C22.2 No. 174
- FT4 flame spread rating
- HAL-FREE FT4-ST1 available upon request
Marking and Identification
- Black and White Pairs
- Black, White and Red Triads
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania