ACIC ISOS 600V

Products

12PR 600v 16 AWG ISOS ACIC

Nexans ref. 6XAAISOS16-12PR

  • Packaging: m
  • Approximate weight: 1271 kg/km
  • Armour outer diameter: 38.58 inches
  • Cable Diameter: 38.58 mm
  • Cable Outer Diameter: 1.52 inches
  • Conductor size (AWG): 16 AWG
  • Diameter Over Armour: 1.11 mm
  • Inner Jacket Diameter: 24.2 mm
  • Inner Jacket Outer Diameter: 1 inches
  • Number of pairs: 12
  • Number of triples: 0
  • Weight: 854 lb/Mft
  • Maximum Pulling Tension: 224.75 kg
  • Maximum Pulling Tension: 495.48 pounds
  • Minimum Bend Radius - Install: 54.1 cm
  • Minimum Bending Radius - Install: 21.3 inches

 

12PR 600v 18 AWG ISOS ACIC

Nexans ref. 6XAAISOS18-12PR

  • Packaging: m
  • Approximate weight: 1070 kg/km
  • Armour outer diameter: 25.9 inches
  • Cable Diameter: 34.8 mm
  • Cable Outer Diameter: 1.37 inches
  • Conductor size (AWG): 18 AWG
  • Diameter Over Armour: 1.02 mm
  • Inner Jacket Diameter: 21.8 mm
  • Inner Jacket Outer Diameter: 0.9 inches
  • Number of pairs: 12
  • Number of triples: 0
  • Weight: 718.933 lb/Mft
  • Maximum Pulling Tension: 141 kg
  • Maximum Pulling Tension: 311 pounds
  • Minimum Bend Radius - Install: 48.65 cm
  • Minimum Bending Radius - Install: 19.15 inches

 

1PR 600v 16 AWG ISOS ACIC

Nexans ref. 6XAAOS16-1PR

  • Packaging: m
  • Approximate weight: 226 kg/km
  • Armour outer diameter: 15.9 inches
  • Cable Diameter: 15.9 mm
  • Cable Outer Diameter: 0.63 inches
  • Conductor size (AWG): 16 AWG
  • Diameter Over Armour: 0.33 mm
  • Inner Jacket Diameter: 6 mm
  • Inner Jacket Outer Diameter: 0.2 inches
  • Number of pairs: 1
  • Number of triples: 0
  • Weight: 152 lb/Mft
  • Maximum Pulling Tension: 18.73 kg
  • Maximum Pulling Tension: 41.29 pounds
  • Minimum Bend Radius - Install: 22.35 cm
  • Minimum Bending Radius - Install: 8.8 inches

 

1PR 600v 18 AWG ISOS ACIC NEW

Nexans ref. 6XAAOS18-1PR

  • Packaging: m
  • Approximate weight: 204 kg/km
  • Armour outer diameter: 7.7 inches
  • Cable Diameter: 15.3 mm
  • Cable Outer Diameter: 0.6 inches
  • Conductor size (AWG): 18 AWG
  • Diameter Over Armour: 0.3 mm
  • Inner Jacket Diameter: 5.4 mm
  • Inner Jacket Outer Diameter: 0.2 inches
  • Number of pairs: 1
  • Number of triples: 0
  • Weight: 137.068 lb/Mft
  • Maximum Pulling Tension: 12 kg
  • Maximum Pulling Tension: 26 pounds
  • Minimum Bend Radius - Install: 21.41 cm
  • Minimum Bending Radius - Install: 8.43 inches

 

1TR 600v 16 AWG ISOS ACIC

Nexans ref. 6XAAOS16-1TR

  • Packaging: m
  • Approximate weight: 252 kg/km
  • Armour outer diameter: 16.36 inches
  • Cable Diameter: 16.36 mm
  • Cable Outer Diameter: 0.64 inches
  • Conductor size (AWG): 16 AWG
  • Diameter Over Armour: 0.35 mm
  • Inner Jacket Diameter: 6.5 mm
  • Inner Jacket Outer Diameter: 0.3 inches
  • Number of pairs: 0
  • Number of triples: 1
  • Weight: 169 lb/Mft
  • Maximum Pulling Tension: 28.09 kg
  • Maximum Pulling Tension: 61.93 pounds
  • Minimum Bend Radius - Install: 22.9 cm
  • Minimum Bending Radius - Install: 9.02 inches

 

1TR 600v 18 AWG ISOS ACIC

Nexans ref. 6XAAOS18-1TR

  • Packaging: m
  • Approximate weight: 224 kg/km
  • Armour outer diameter: 8.1 inches
  • Cable Diameter: 15.7 mm
  • Cable Outer Diameter: 0.62 inches
  • Conductor size (AWG): 18 AWG
  • Diameter Over Armour: 0.32 mm
  • Inner Jacket Diameter: 5.8 mm
  • Inner Jacket Outer Diameter: 0.2 inches
  • Number of pairs: 0
  • Number of triples: 1
  • Weight: 150 lb/Mft
  • Maximum Pulling Tension: 18 kg
  • Maximum Pulling Tension: 39 pounds
  • Minimum Bend Radius - Install: 21.98 cm
  • Minimum Bending Radius - Install: 8.65 inches

 

2PR 600v 16 AWG ISOS ACIC

Nexans ref. 6XAAISOS16-2PR

  • Packaging: m
  • Approximate weight: 423 kg/km
  • Armour outer diameter: 22.86 inches
  • Cable Diameter: 22.86 mm
  • Cable Outer Diameter: 0.9 inches
  • Conductor size (AWG): 16 AWG
  • Diameter Over Armour: 0.6 mm
  • Inner Jacket Diameter: 12.2 mm
  • Inner Jacket Outer Diameter: 0.5 inches
  • Number of pairs: 2
  • Number of triples: 0
  • Weight: 284 lb/Mft
  • Maximum Pulling Tension: 37.46 kg
  • Maximum Pulling Tension: 82.58 pounds
  • Minimum Bend Radius - Install: 32 cm
  • Minimum Bending Radius - Install: 12.6 inches

 

2PR 600v 18 AWG ISOS ACIC

Nexans ref. 6XAAISOS18-2PR

  • Packaging: m
  • Approximate weight: 377 kg/km
  • Armour outer diameter: 14.1 inches
  • Cable Diameter: 21.6 mm
  • Cable Outer Diameter: 0.85 inches
  • Conductor size (AWG): 18 AWG
  • Diameter Over Armour: 0.55 mm
  • Inner Jacket Diameter: 11 mm
  • Inner Jacket Outer Diameter: 0.4 inches
  • Number of pairs: 2
  • Number of triples: 0
  • Weight: 253.306 lb/Mft
  • Maximum Pulling Tension: 23 kg
  • Maximum Pulling Tension: 52 pounds
  • Minimum Bend Radius - Install: 30.3 cm
  • Minimum Bending Radius - Install: 11.93 inches

 

2TR 600v 16 AWG ISOS ACIC

Nexans ref. 6XAAISOS16-2TR

  • Packaging: m
  • Approximate weight: 478 kg/km
  • Armour outer diameter: 23.75 inches
  • Cable Diameter: 23.75 mm
  • Cable Outer Diameter: 0.94 inches
  • Conductor size (AWG): 16 AWG
  • Diameter Over Armour: 0.64 mm
  • Inner Jacket Diameter: 13.1 mm
  • Inner Jacket Outer Diameter: 0.5 inches
  • Number of pairs: 0
  • Number of triples: 2
  • Weight: 321 lb/Mft
  • Maximum Pulling Tension: 56.18 kg
  • Maximum Pulling Tension: 123.86 pounds
  • Minimum Bend Radius - Install: 33.25 cm
  • Minimum Bending Radius - Install: 13.09 inches

 

2TR 600v 18 AWG ISOS ACIC

Nexans ref. 6XAAISOS18-2TR

  • Packaging: m
  • Approximate weight: 419 kg/km
  • Armour outer diameter: 14.9 inches
  • Cable Diameter: 22.4 mm
  • Cable Outer Diameter: 0.88 inches
  • Conductor size (AWG): 18 AWG
  • Diameter Over Armour: 0.59 mm
  • Inner Jacket Diameter: 11.8 mm
  • Inner Jacket Outer Diameter: 0.5 inches
  • Number of pairs: 0
  • Number of triples: 2
  • Weight: 281.526 lb/Mft
  • Maximum Pulling Tension: 35 kg
  • Maximum Pulling Tension: 78 pounds
  • Minimum Bend Radius - Install: 31.43 cm
  • Minimum Bending Radius - Install: 12.38 inches

 

4PR 600v 16AWG ISOS ACIC

Nexans ref. 6XAAISOS16-4PR

  • Packaging: m
  • Approximate weight: 561 kg/km
  • Armour outer diameter: 26.16 inches
  • Cable Diameter: 26.16 mm
  • Cable Outer Diameter: 1.03 inches
  • Conductor size (AWG): 16 AWG
  • Diameter Over Armour: 0.7 mm
  • Inner Jacket Diameter: 14.7 mm
  • Inner Jacket Outer Diameter: 0.6 inches
  • Number of pairs: 4
  • Number of triples: 0
  • Weight: 377 lb/Mft
  • Maximum Pulling Tension: 74.92 kg
  • Maximum Pulling Tension: 165.16 pounds
  • Minimum Bend Radius - Install: 36.58 cm
  • Minimum Bending Radius - Install: 14.4 inches

 

4PR 600v 18 AWG ISOS ACIC

Nexans ref. 6XAAISOS18-4PR

  • Packaging: m
  • Approximate weight: 483 kg/km
  • Armour outer diameter: 16.3 inches
  • Cable Diameter: 23.9 mm
  • Cable Outer Diameter: 0.94 inches
  • Conductor size (AWG): 18 AWG
  • Diameter Over Armour: 0.64 mm
  • Inner Jacket Diameter: 13.3 mm
  • Inner Jacket Outer Diameter: 0.5 inches
  • Number of pairs: 4
  • Number of triples: 0
  • Weight: 324.528 lb/Mft
  • Maximum Pulling Tension: 47 kg
  • Maximum Pulling Tension: 104 pounds
  • Minimum Bend Radius - Install: 33.43 cm
  • Minimum Bending Radius - Install: 13.16 inches

 

4TR 600v 16 AWG ISOS ACIC

Nexans ref. 6XAAISOS16-4TR

  • Packaging: m
  • Approximate weight: 693 kg/km
  • Armour outer diameter: 29.11 inches
  • Cable Diameter: 29.11 mm
  • Cable Outer Diameter: 1.15 inches
  • Conductor size (AWG): 16 AWG
  • Diameter Over Armour: 0.82 mm
  • Inner Jacket Diameter: 17.7 mm
  • Inner Jacket Outer Diameter: 0.7 inches
  • Number of pairs: 0
  • Number of triples: 4
  • Weight: 466 lb/Mft
  • Maximum Pulling Tension: 112.37 kg
  • Maximum Pulling Tension: 247.73 pounds
  • Minimum Bend Radius - Install: 40.75 cm
  • Minimum Bending Radius - Install: 16.04 inches

 

4TR 600v 18 AWG ISOS ACIC

Nexans ref. 6XAAISOS18-4TR

  • Packaging: m
  • Approximate weight: 592 kg/km
  • Armour outer diameter: 19.0 inches
  • Cable Diameter: 27.3 mm
  • Cable Outer Diameter: 1.08 inches
  • Conductor size (AWG): 18 AWG
  • Diameter Over Armour: 0.75 mm
  • Inner Jacket Diameter: 15.9 mm
  • Inner Jacket Outer Diameter: 0.6 inches
  • Number of pairs: 0
  • Number of triples: 4
  • Weight: 398 lb/Mft
  • Maximum Pulling Tension: 70 kg
  • Maximum Pulling Tension: 155 pounds
  • Minimum Bend Radius - Install: 38.3 cm
  • Minimum Bending Radius - Install: 15.08 inches

 

6PR 600v 16 AWG ISOS ACIC

Nexans ref. 6XAAISOS16-6PR

  • Packaging: m
  • Approximate weight: 693 kg/km
  • Armour outer diameter: 28.63 inches
  • Cable Diameter: 28.63 mm
  • Cable Outer Diameter: 1.13 inches
  • Conductor size (AWG): 16 AWG
  • Diameter Over Armour: 0.8 mm
  • Inner Jacket Diameter: 17.2 mm
  • Inner Jacket Outer Diameter: 0.7 inches
  • Number of pairs: 6
  • Number of triples: 0
  • Weight: 466 lb/Mft
  • Maximum Pulling Tension: 112.37 kg
  • Maximum Pulling Tension: 247.74 pounds
  • Minimum Bend Radius - Install: 40.13 cm
  • Minimum Bending Radius - Install: 15.8 inches

 

6PR 600v 18 AWG ISOS ACIC

Nexans ref. 6XAAISOS18-6PR

  • Packaging: m
  • Approximate weight: 593 kg/km
  • Armour outer diameter: 18.5 inches
  • Cable Diameter: 26.9 mm
  • Cable Outer Diameter: 1.06 inches
  • Conductor size (AWG): 18 AWG
  • Diameter Over Armour: 0.73 mm
  • Inner Jacket Diameter: 15.5 mm
  • Inner Jacket Outer Diameter: 0.6 inches
  • Number of pairs: 6
  • Number of triples: 0
  • Weight: 399 lb/Mft
  • Maximum Pulling Tension: 70 kg
  • Maximum Pulling Tension: 155 pounds
  • Minimum Bend Radius - Install: 37.69 cm
  • Minimum Bending Radius - Install: 14.84 inches

 

6TR 600v 16 AWG ISOS ACIC

Nexans ref. 6XAAISOS16-6TR

  • Packaging: m
  • Approximate weight: 1057 kg/km
  • Armour outer diameter: 34.54 inches
  • Cable Diameter: 34.54 mm
  • Cable Outer Diameter: 1.36 inches
  • Conductor size (AWG): 16 AWG
  • Diameter Over Armour: 1.01 mm
  • Inner Jacket Diameter: 21.6 mm
  • Inner Jacket Outer Diameter: 0.8 inches
  • Number of pairs: 0
  • Number of triples: 6
  • Weight: 710 lb/Mft
  • Maximum Pulling Tension: 168.55 kg
  • Maximum Pulling Tension: 371.59 pounds
  • Minimum Bend Radius - Install: 48.36 cm
  • Minimum Bending Radius - Install: 19.04 inches

 

6TR 600v 18 AWG ISOS ACIC

Nexans ref. 6XAAISOS18-6TR

  • Packaging: m
  • Approximate weight: 813 kg/km
  • Armour outer diameter: 23.5 inches
  • Cable Diameter: 31.9 mm
  • Cable Outer Diameter: 1.25 inches
  • Conductor size (AWG): 18 AWG
  • Diameter Over Armour: 0.93 mm
  • Inner Jacket Diameter: 19.4 mm
  • Inner Jacket Outer Diameter: 0.8 inches
  • Number of pairs: 0
  • Number of triples: 6
  • Weight: 546 lb/Mft
  • Maximum Pulling Tension: 106 kg
  • Maximum Pulling Tension: 233 pounds
  • Minimum Bend Radius - Install: 44.63 cm
  • Minimum Bending Radius - Install: 17.57 inches

 

8PR 600v 16 AWG ISOS ACIC

Nexans ref. 6XAAISOS16-8PR

  • Packaging: m
  • Approximate weight: 992 kg/km
  • Armour outer diameter: 33.07 inches
  • Cable Diameter: 33.07 mm
  • Cable Outer Diameter: 1.3 inches
  • Conductor size (AWG): 16 AWG
  • Diameter Over Armour: 0.95 mm
  • Inner Jacket Diameter: 20.1 mm
  • Inner Jacket Outer Diameter: 0.8 inches
  • Number of pairs: 8
  • Number of triples: 0
  • Weight: 667 lb/Mft
  • Maximum Pulling Tension: 149.83 kg
  • Maximum Pulling Tension: 330.32 pounds
  • Minimum Bend Radius - Install: 46.23 cm
  • Minimum Bending Radius - Install: 18.2 inches

 

8PR 600v 18 AWG ISOS ACIC

Nexans ref. 6XAAISOS18-8PR

  • Packaging: m
  • Approximate weight: 768 kg/km
  • Armour outer diameter: 22.2 inches
  • Cable Diameter: 30.5 mm
  • Cable Outer Diameter: 1.2 inches
  • Conductor size (AWG): 18 AWG
  • Diameter Over Armour: 0.87 mm
  • Inner Jacket Diameter: 18.1 mm
  • Inner Jacket Outer Diameter: 0.7 inches
  • Number of pairs: 8
  • Number of triples: 0
  • Weight: 516.019 lb/Mft
  • Maximum Pulling Tension: 94 kg
  • Maximum Pulling Tension: 207 pounds
  • Minimum Bend Radius - Install: 42.74 cm
  • Minimum Bending Radius - Install: 16.83 inches

 

8TR 600v 16 AWG ISOS ACIC

Nexans ref. 6XAAISOS16-8TR

  • Packaging: m
  • Approximate weight: 1268 kg/km
  • Armour outer diameter: 39.24 inches
  • Cable Diameter: 39.24 mm
  • Cable Outer Diameter: 1.54 inches
  • Conductor size (AWG): 16 AWG
  • Diameter Over Armour: 1.14 mm
  • Inner Jacket Diameter: 24.9 mm
  • Inner Jacket Outer Diameter: 1 inches
  • Number of pairs: 0
  • Number of triples: 8
  • Weight: 852 lb/Mft
  • Maximum Pulling Tension: 224.73 kg
  • Maximum Pulling Tension: 495.45 pounds
  • Minimum Bend Radius - Install: 54.94 cm
  • Minimum Bending Radius - Install: 21.63 inches

 

8TR 600v 18 AWG ISOS ACIC

Nexans ref. 6XAAISOS18-8TR

  • Packaging: m
  • Approximate weight: 1066 kg/km
  • Armour outer diameter: 26.5 inches
  • Cable Diameter: 35.4 mm
  • Cable Outer Diameter: 1.39 inches
  • Conductor size (AWG): 18 AWG
  • Diameter Over Armour: 1.04 mm
  • Inner Jacket Diameter: 22.4 mm
  • Inner Jacket Outer Diameter: 0.9 inches
  • Number of pairs: 0
  • Number of triples: 8
  • Weight: 717 lb/Mft
  • Maximum Pulling Tension: 141 kg
  • Maximum Pulling Tension: 311 pounds
  • Minimum Bend Radius - Install: 49.5 cm
  • Minimum Bending Radius - Install: 19.49 inches

 

Description

Description

Standards

  • Product
    CSA C22.2 N° 239; CSA C22.2 N° 174; CSA C22.2 N° 2556; CSA C22.2 N° 38
  • Test
    ICEA T-30 520; IEEE 1202; IEEE 383; UL 1685

Applications

 Armoured Control and Instrumentation Cable manufactured to strict Canadian Standards Association (CSA) requirements, it is a highly rugged, multi-conductor cable designed to transmit analog or digital signals in heavy industrial, harsh, and hazardous environments. Used for connecting PLC (Programmable Logic Controller) systems to field instruments, sensors, valves, and actuators.

  • For use in raceways, ventilated, non-ventilated and ladder-type cable trays.
  • For dry, damp or wet locations, in ceiling air-handling plenums, direct burial, exposed and concealed wiring.
  • Approved for all Hazardous Locations (HL-ABCD) as per CE Code Part I 2024 Section 18, when installed with approved connectors.

Specifications and Compliances

  • CSA C22.2 No. 239, Control and instrumentation cables (Type ACIC)
  • CSA C22.2 No. 38, Thermoset-insulated wires and cables (Type RW90)
  • CSA C22.2 No. 174, Cables and cable glands for use in hazardous locations (HL-ABCD)
  • CSA C22.2 No. 2556 FT4, UL 1685 Vertical-Tray Flame Test IEEE 383 & 1202, ICEA T-30-520 (70,000 BTU/hr) Vertical Flame Test rated
  • -40°C Cold Bend and -40°C Cold Impact
  • Sunlight Resistant, SUN RES and Low Acid Gas, AG14

Highlights

  • Nexans ACIC Cables are: Available from stock
  • Versatile & Flexible
  • Resistant to Mechanical Abuse and Corrosion
  • Compact and Reliable
  • 90°C to -40°C
  • Low Acid Gas (AG14) • Sunlight resistant
  • LEAD FREE & RoHS compliant
  • Marked HL to CSA C22.2 No. 174
  • FT4 flame spread rating
  • HAL-FREE FT4-ST1 available upon request

Marking and Identification

  1. Black and White Pairs 
  2. Black, White and Red Triads

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Armour type
Aluminum Interlock
Conductor Material
Tinned copper
Insulation
Cross-linked polyethylene
Jacket material
PVC
Shielding
Aluminum Mylar

Dimensional characteristics

Dimensional characteristics

Average insulation thickness
.03 inches
Average insulation thickness
0.762 mm

Electrical characteristics

Electrical characteristics

Maximum operating voltage
600 V

Usage characteristics

Usage characteristics

Maximum operating temperature
90 °C
Minimum installation temperature
-40 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close