- About Us
- Product Datasheets
- Products Overview
- Services and Solutions
- News
- Tools & Documents
-
Webinars
- Webinars
- Understanding North American Medium Voltage Cable Standards
- Understanding DriveRx® VFD Cables
- Exploring Wire and Cable Used in Data Centres
- Exploring Wire and Cable Used in Healthcare
- Key 2024 CE Code Changes Impacting Wire and Cable
- Industrial Power Cables: Conductors in Shining Armour
- Sustainability In the Wire & Cable Industry
- Copper Demands and Recycling
- Wiring for Canadian Homes - Part 3
- Medium Voltage Solutions for Solar Applications
- Wiring for Canadian Homes - Part 2
- Wiring for Canadian Homes - Part 1
- Cable Manufacturing
- REEL Talk
- ULTRACKER Connected Reels Tracking Solution
- Installations 102
- Installations 101
- Copper & Aluminum: What You Need to Know
- Cables 101
- Raw Material Insights
- Renewable Energy - Wind & Solar Energy Trends
- Emerging Trends for Utility Cables
- Search
- Contact us
- Compare
- Sign in
CIC ISOS 300V
CIC ISOS 300V
300V CIC Cable Individual and Overall Aluminum Mylar Shielded Tinned Copper Pairs or Triads with Tinned Copper Drain Wires with a PVC Outer Jacket
Read more12PR 300V 16 AWG ISOS CIC
Nexans ref. 3XNAISOS16-12PR
- Packaging: m (1000m)
- Approximate weight: 587.68 kg/km
- Cable Diameter: 22.38 mm
- Cable Outer Diameter: 0.88 inches
- Conductor size (AWG): 16
- Number of pairs: 12
- Number of triples: 0
- Weight: 394.9 lb/Mft
- Maximum operating voltage: 600 V
- Maximum Pulling Tension: 224.73 kg
- Maximum Pulling Tension: 495.45 pounds
- Minimum Bend Radius - Install: 313.36 cm
- Minimum Bending Radius - Install: 12.34 inches
12PR 300V 18 AWG ISOS CIC
Nexans ref. 3XNAISOS18-12PR
- Packaging: m (1000m)
- Approximate weight: 509.69 kg/km
- Cable Diameter: 24.42 mm
- Cable Outer Diameter: 0.96 inches
- Conductor size (AWG): 18
- Number of pairs: 12
- Number of triples: 0
- Weight: 342.498 lb/Mft
- Maximum operating voltage: 300 V
- Maximum Pulling Tension: 140.85 kg
- Maximum Pulling Tension: 310.52 pounds
- Minimum Bend Radius - Install: 39.08 cm
- Minimum Bending Radius - Install: 15.38 inches
1PR 300V 16 AWG ISOS CIC
Nexans ref. 3XNAOS16-1PR
- Packaging: m (1000m)
- Approximate weight: 61.68 kg/km
- Cable Diameter: 6.84 mm
- Cable Outer Diameter: 0.27 inches
- Conductor size (AWG): 16
- Number of pairs: 1
- Number of triples: 0
- Weight: 41.444 lb/Mft
- Maximum operating voltage: 600 V
- Maximum Pulling Tension: 18.73 kg
- Maximum Pulling Tension: 41.29 pounds
- Minimum Bend Radius - Install: 95.73 cm
- Minimum Bending Radius - Install: 3.77 inches
1PR 300V 18 AWG ISOS CIC
Nexans ref. 3XNAOS18-1PR
- Packaging: m (1000m)
- Approximate weight: 54.99 kg/km
- Cable Diameter: 7.14 mm
- Cable Outer Diameter: 0.28 inches
- Conductor size (AWG): 18
- Number of pairs: 1
- Number of triples: 0
- Weight: 36.949 lb/Mft
- Maximum operating voltage: 300 V
- Maximum Pulling Tension: 11.74 kg
- Maximum Pulling Tension: 25.88 pounds
- Minimum Bend Radius - Install: 11.43 cm
- Minimum Bending Radius - Install: 4.5 inches
1TR 300V 16 AWG ISOS CIC
Nexans ref. 3XNAOS16-1TR
- Packaging: m (1000m)
- Approximate weight: 86.51 kg/km
- Cable Diameter: 8.09 mm
- Cable Outer Diameter: 0.32 inches
- Conductor size (AWG): 16
- Number of pairs: 0
- Number of triples: 1
- Weight: 58.129 lb/Mft
- Maximum operating voltage: 600 V
- Maximum Pulling Tension: 28.09 kg
- Maximum Pulling Tension: 61.93 pounds
- Minimum Bend Radius - Install: 113.2 cm
- Minimum Bending Radius - Install: 4.46 inches
1TR300V 18 AWG ISOS CIC
Nexans ref. 3XNAOS18-1TR
- Packaging: m (1000m)
- Approximate weight: 67.12 kg/km
- Cable Diameter: 7.43 mm
- Cable Outer Diameter: 0.29 inches
- Conductor size (AWG): 18
- Number of pairs: 0
- Number of triples: 1
- Weight: 45.104 lb/Mft
- Maximum operating voltage: 300 V
- Maximum Pulling Tension: 17.61 kg
- Maximum Pulling Tension: 38.81 pounds
- Minimum Bend Radius - Install: 11.89 cm
- Minimum Bending Radius - Install: 4.68 inches
24PR 300V 16 AWG ISOS CIC
Nexans ref. 3XNAISOS16-24PR
- Packaging: m (1000m)
- Approximate weight: 1063.21 kg/km
- Cable Diameter: 31.58 mm
- Cable Outer Diameter: 1.24 inches
- Conductor size (AWG): 16
- Number of pairs: 24
- Number of triples: 0
- Weight: 714.441 lb/Mft
- Maximum operating voltage: 600 V
- Maximum Pulling Tension: 449.47 kg
- Maximum Pulling Tension: 990.9 pounds
- Minimum Bend Radius - Install: 442.08 cm
- Minimum Bending Radius - Install: 17.41 inches
24PR 300V 18 AWG ISOS CIC
Nexans ref. 3XNAISOS18-24PR
- Packaging: m (1000m)
- Approximate weight: 897.14 kg/km
- Cable Diameter: 33.41 mm
- Cable Outer Diameter: 1.31 inches
- Conductor size (AWG): 18
- Number of pairs: 24
- Number of triples: 0
- Weight: 602.852 lb/Mft
- Maximum operating voltage: 300 V
- Maximum Pulling Tension: 281.7 kg
- Maximum Pulling Tension: 621.04 pounds
- Minimum Bend Radius - Install: 66.81 cm
- Minimum Bending Radius - Install: 26.3 inches
2PR 300V 16 AWG ISOS CIC
Nexans ref. 3XNAISOS16-2PR
- Packaging: m (1000m)
- Approximate weight: 127.09 kg/km
- Cable Diameter: 11.59 mm
- Cable Outer Diameter: 0.46 inches
- Conductor size (AWG): 16
- Number of pairs: 2
- Number of triples: 0
- Weight: 85.4 lb/Mft
- Maximum operating voltage: 600 V
- Maximum Pulling Tension: 37.46 kg
- Maximum Pulling Tension: 82.58 pounds
- Minimum Bend Radius - Install: 162.3 cm
- Minimum Bending Radius - Install: 6.39 inches
2PR 300V 18 AWG ISOS CIC
Nexans ref. 3XNAISOS18-2PR
- Packaging: m (1000m)
- Approximate weight: 108.91 kg/km
- Cable Diameter: 12.2 mm
- Cable Outer Diameter: 0.48 inches
- Conductor size (AWG): 18
- Number of pairs: 2
- Number of triples: 0
- Weight: 73.187 lb/Mft
- Maximum operating voltage: 300 V
- Maximum Pulling Tension: 23.48 kg
- Maximum Pulling Tension: 51.75 pounds
- Minimum Bend Radius - Install: 19.52 cm
- Minimum Bending Radius - Install: 7.69 inches
2TR 300V 16 AWG ISOS CIC
Nexans ref. 3XNAISOS16-2TR
- Packaging: m (1000m)
- Approximate weight: 195.82 kg/km
- Cable Diameter: 14.85 mm
- Cable Outer Diameter: 0.58 inches
- Conductor size (AWG): 16
- Number of pairs: 0
- Number of triples: 2
- Weight: 131.583 lb/Mft
- Maximum operating voltage: 600 V
- Maximum Pulling Tension: 56.18 kg
- Maximum Pulling Tension: 123.86 pounds
- Minimum Bend Radius - Install: 207.91 cm
- Minimum Bending Radius - Install: 8.19 inches
2TR 300V 18 AWG ISOS CIC
Nexans ref. 3XNAISOS18-2TR
- Packaging: m (1000m)
- Approximate weight: 132.59 kg/km
- Cable Diameter: 12.78 mm
- Cable Outer Diameter: 0.5 inches
- Conductor size (AWG): 18
- Number of pairs: 0
- Number of triples: 2
- Weight: 89.096 lb/Mft
- Maximum operating voltage: 300 V
- Maximum Pulling Tension: 35.21 kg
- Maximum Pulling Tension: 77.63 pounds
- Minimum Bend Radius - Install: 20.45 cm
- Minimum Bending Radius - Install: 8.05 inches
3PR 300V 16 AWG ISOS CIC
Nexans ref. 3XNAISOS16-3PR
- Packaging: m (1000m)
- Approximate weight: 163.11 kg/km
- Cable Diameter: 12.28 mm
- Cable Outer Diameter: 0.48 inches
- Conductor size (AWG): 16
- Number of pairs: 3
- Number of triples: 0
- Weight: 109.602 lb/Mft
- Maximum operating voltage: 600 V
- Maximum Pulling Tension: 56.18 kg
- Maximum Pulling Tension: 123.86 pounds
- Minimum Bend Radius - Install: 171.85 cm
- Minimum Bending Radius - Install: 6.77 inches
3PR 300V 18 AWG ISOS CIC
Nexans ref. 3XNAISOS18-3PR
- Packaging: m (1000m)
- Approximate weight: 138.19 kg/km
- Cable Diameter: 12.93 mm
- Cable Outer Diameter: 0.51 inches
- Conductor size (AWG): 18
- Number of pairs: 3
- Number of triples: 0
- Weight: 92.858 lb/Mft
- Maximum operating voltage: 300 V
- Maximum Pulling Tension: 35.21 kg
- Maximum Pulling Tension: 77.63 pounds
- Minimum Bend Radius - Install: 20.69 cm
- Minimum Bending Radius - Install: 8.14 inches
4PR 300V 16 AWG ISOS CIC
Nexans ref. 3XNAISOS16-4PR
- Packaging: m (1000m)
- Approximate weight: 226.26 kg/km
- Cable Diameter: 14.22 mm
- Cable Outer Diameter: 0.56 inches
- Conductor size (AWG): 16
- Number of pairs: 4
- Number of triples: 0
- Weight: 152.042 lb/Mft
- Maximum operating voltage: 600 V
- Maximum Pulling Tension: 74.91 kg
- Maximum Pulling Tension: 165.15 pounds
- Minimum Bend Radius - Install: 199.09 cm
- Minimum Bending Radius - Install: 7.84 inches
4PR 300V 18 AWG ISOS CIC
Nexans ref. 3XNAISOS18-4PR
- Packaging: m (1000m)
- Approximate weight: 194.53 kg/km
- Cable Diameter: 14.96 mm
- Cable Outer Diameter: 0.59 inches
- Conductor size (AWG): 18
- Number of pairs: 4
- Number of triples: 0
- Weight: 130.721 lb/Mft
- Maximum operating voltage: 300 V
- Maximum Pulling Tension: 46.95 kg
- Maximum Pulling Tension: 103.51 pounds
- Minimum Bend Radius - Install: 23.93 cm
- Minimum Bending Radius - Install: 9.42 inches
4TR 300V 16 AWG ISOS CIC
Nexans ref. 3XNAISOS16-4TR
- Packaging: m (1000m)
- Approximate weight: 316.05 kg/km
- Cable Diameter: 17.23 mm
- Cable Outer Diameter: 0.68 inches
- Conductor size (AWG): 16
- Number of pairs: 0
- Number of triples: 4
- Weight: 212.373 lb/Mft
- Maximum operating voltage: 600 V
- Maximum Pulling Tension: 112.37 kg
- Maximum Pulling Tension: 247.73 pounds
- Minimum Bend Radius - Install: 241.2 cm
- Minimum Bending Radius - Install: 9.5 inches
4TR 300V 18 AWG ISOS CIC
Nexans ref. 3XNAISOS18-4TR
- Packaging: m (1000m)
- Approximate weight: 240.62 kg/km
- Cable Diameter: 15.65 mm
- Cable Outer Diameter: 0.62 inches
- Conductor size (AWG): 18
- Number of pairs: 0
- Number of triples: 4
- Weight: 161.689 lb/Mft
- Maximum operating voltage: 300 V
- Maximum Pulling Tension: 70.42 kg
- Maximum Pulling Tension: 155.26 pounds
- Minimum Bend Radius - Install: 25.04 cm
- Minimum Bending Radius - Install: 9.86 inches
6PR 300V 16 AWG ISOS CIC
Nexans ref. 3XNAISOS16-6PR
- Packaging: m (1000m)
- Approximate weight: 304.37 kg/km
- Cable Diameter: 16.09 mm
- Cable Outer Diameter: 0.63 inches
- Conductor size (AWG): 16
- Number of pairs: 6
- Number of triples: 0
- Weight: 204.528 lb/Mft
- Maximum operating voltage: 600 V
- Maximum Pulling Tension: 112.37 kg
- Maximum Pulling Tension: 247.73 pounds
- Minimum Bend Radius - Install: 225.22 cm
- Minimum Bending Radius - Install: 8.87 inches
6PR 300V 18 AWG ISOS CIC
Nexans ref. 3XNAISOS18-6PR
- Packaging: m (1000m)
- Approximate weight: 265.29 kg/km
- Cable Diameter: 17.82 mm
- Cable Outer Diameter: 0.7 inches
- Conductor size (AWG): 18
- Number of pairs: 6
- Number of triples: 0
- Weight: 178.268 lb/Mft
- Maximum operating voltage: 300 V
- Maximum Pulling Tension: 70.42 kg
- Maximum Pulling Tension: 155.26 pounds
- Minimum Bend Radius - Install: 28.51 cm
- Minimum Bending Radius - Install: 11.23 inches
6TR 300V 16 AWG ISOS CIC
Nexans ref. 3XNAISOS16-6TR
- Packaging: m (1000m)
- Approximate weight: 443.53 kg/km
- Cable Diameter: 20.65 mm
- Cable Outer Diameter: 0.81 inches
- Conductor size (AWG): 16
- Number of pairs: 0
- Number of triples: 6
- Weight: 298.037 lb/Mft
- Maximum operating voltage: 600 V
- Maximum Pulling Tension: 168.55 kg
- Maximum Pulling Tension: 371.59 pounds
- Minimum Bend Radius - Install: 289.11 cm
- Minimum Bending Radius - Install: 11.38 inches
6TR 300V 18 AWG ISOS CIC
Nexans ref. 3XNAISOS18-6TR
- Packaging: m (1000m)
- Approximate weight: 333.19 kg/km
- Cable Diameter: 18.68 mm
- Cable Outer Diameter: 0.74 inches
- Conductor size (AWG): 18
- Number of pairs: 0
- Number of triples: 6
- Weight: 223.893 lb/Mft
- Maximum operating voltage: 300 V
- Maximum Pulling Tension: 105.64 kg
- Maximum Pulling Tension: 232.89 pounds
- Minimum Bend Radius - Install: 29.9 cm
- Minimum Bending Radius - Install: 11.77 inches
8PR 300V 16 AWG ISOS CIC
Nexans ref. 3XNAISOS16-8PR
- Packaging: m (1000m)
- Approximate weight: 384.81 kg/km
- Cable Diameter: 18.27 mm
- Cable Outer Diameter: 0.72 inches
- Conductor size (AWG): 16
- Number of pairs: 8
- Number of triples: 0
- Weight: 258.583 lb/Mft
- Maximum operating voltage: 600 V
- Maximum Pulling Tension: 149.82 kg
- Maximum Pulling Tension: 330.3 pounds
- Minimum Bend Radius - Install: 255.8 cm
- Minimum Bending Radius - Install: 10.07 inches
8PR 300V 18 AWG ISOS CIC
Nexans ref. 3XNAISOS18-8PR
- Packaging: m (1000m)
- Approximate weight: 326.26 kg/km
- Cable Diameter: 19.28 mm
- Cable Outer Diameter: 0.76 inches
- Conductor size (AWG): 18
- Number of pairs: 8
- Number of triples: 0
- Weight: 219.239 lb/Mft
- Maximum operating voltage: 300 V
- Maximum Pulling Tension: 93.9 kg
- Maximum Pulling Tension: 207.01 pounds
- Minimum Bend Radius - Install: 30.84 cm
- Minimum Bending Radius - Install: 12.14 inches
8TR 300V 16 AWG ISOS CIC
Nexans ref. 3XNAISOS16-8TR
- Packaging: m (1000m)
- Approximate weight: 610.12 kg/km
- Cable Diameter: 23.41 mm
- Cable Outer Diameter: 0.92 inches
- Conductor size (AWG): 16
- Number of pairs: 0
- Number of triples: 8
- Weight: 409.982 lb/Mft
- Maximum operating voltage: 600 V
- Maximum Pulling Tension: 224.73 kg
- Maximum Pulling Tension: 495.45 pounds
- Minimum Bend Radius - Install: 327.69 cm
- Minimum Bending Radius - Install: 12.9 inches
8TR 300V 18 AWG ISOS CIC
Nexans ref. 3XNAISOS18-8TR
- Packaging: m (1000m)
- Approximate weight: 415.39 kg/km
- Cable Diameter: 20.23 mm
- Cable Outer Diameter: 0.8 inches
- Conductor size (AWG): 18
- Number of pairs: 0
- Number of triples: 8
- Weight: 279.132 lb/Mft
- Maximum operating voltage: 300 V
- Maximum Pulling Tension: 140.85 kg
- Maximum Pulling Tension: 310.52 pounds
- Minimum Bend Radius - Install: 32.37 cm
- Minimum Bending Radius - Install: 12.74 inches
Description
Description
Standards
-
ProductCSA C22.2 N° 239; CSA C22.2 N° 2556; CSA C22.2 N° 38
-
TestIEEE 1202; IEEE 383; UL 1685
Applications
Control and Instrumentation Cable manufactured to strict Canadian Standards Association (CSA) requirements, it is a highly rugged, multi-conductor cable designed to transmit analog or digital signals in heavy industrial, harsh, and hazardous environments. Used for connecting PLC (Programmable Logic Controller) systems to field instruments, sensors, valves, and actuators.
- For use in raceways, ventilated, non-ventilated and ladder-type cable trays.
- For dry, damp or wet locations and ceiling air-handling plenums.
Specifications and Compliances
- CSA C22.2 No. 239, Control and instrumentation cables (Type CIC)
- CSA C22.2 No. 38, Thermoset-insulated wires and cables (Type RW90)
- CSA C22.2 No. 2556 FT4, UL 1685 Vertical-Tray Flame Test
- IEEE 383 & 1202, ICEA T-30-520 (70,000 BTU/hr) Vertical Flame Test rated
- -40°C Cold Bend and -40°C Cold Impact
- Sunlight Resistant, SUN RES. Low Acid Gas, AG14.
Highlights
- Nexans CIC Cables are: Available from stock
- Versatile & Flexible
- Resistant to Mechanical Abuse and Corrosion
- Compact and Reliable
- 90°C to -40°C
- Low Acid Gas (AG14) • Sunlight resistant
- LEAD FREE & RoHS compliant
- Marked HL to CSA C22.2 No. 174
- FT4 flame spread rating
- HAL-FREE FT4-ST1 available upon request
Marking and Identification
- Black and White Pairs
- Black, White and Red Triads
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics